Literature DB >> 22773505

Effect of restoration of combined offset on stability of large head THA.

Michael Robinson1, Lindsey Bornstein, Brandon Mennear, Mathias Bostrom, Bryan Nestor, Douglas Padgett, Geoffrey Westrich.   

Abstract

Improvements in bearing technology have resulted in a reduction in wear and larger femoral heads to reduce dislocation rates. We retrospectively reviewed 668 primary THAs (580 patients) inserted with 32 mm or 36 mm femoral heads (1/2003-6/2007) performed through a posterior approach with posterior repair. Patients received a questionnaire assessing instability and dislocations. We compared clinical and radiographic data between patients with and without dislocations. Follow-up averaged 3.4 years (range 2-6.6 years). The dislocation rate was 1.3% (9/668). Decreasing the combined postoperative offset (lateral offset + medial offset measurements) and using acetabular cups larger than 58 mm in outer diameter increased the risk of dislocation. A majority of the hips that dislocated had negative combined offset and abduction angles in the upper and lower quartiles of all hips studied. Appropriate positioning should be used to minimise dislocation risk in THAs inserted with large femoral heads.

Entities:  

Mesh:

Year:  2012        PMID: 22773505     DOI: 10.5301/HIP.2012.9283

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  17 in total

1.  What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

Authors:  Matthew P Abdel; Philipp von Roth; Matthew T Jennings; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

2.  [Measurement of acetabular cup inclination in anteroposterior pelvic radiogram : An indicator of quality after primary total hip arthroplasty?]

Authors:  T Loitsch; T Freitag; F Leucht; H Reichel; R Bieger
Journal:  Orthopade       Date:  2018-12       Impact factor: 1.087

3.  Accuracy of the modified Hardinge approach in acetabular positioning.

Authors:  Prateek Goyal; Adrian Lau; Richard McCalden; Matthew G Teeter; James L Howard; Brent A Lanting
Journal:  Can J Surg       Date:  2016-08       Impact factor: 2.089

4.  Does dual-mobility cup geometry affect posterior horizontal dislocation distance?

Authors:  Christopher Heffernan; Samik Banerjee; Jim Nevelos; James Macintyre; Kimona Issa; David C Markel; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2014-01-24       Impact factor: 4.176

5.  Mid- to long-term results of the Cone-Conical modular system in revision hip arthroplasty.

Authors:  Abd-Allah El Ashmawy; Hazem A H Hosny; Ahmed El-Bakoury; Rathan Yarlagadda; Jonathan Keenan
Journal:  Int Orthop       Date:  2021-10-12       Impact factor: 3.075

6.  Subsidence of monoblock and modular titanium fluted tapered stems in revision hip arthroplasty: A retrospective multicentre comparison study.

Authors:  Eoghan Pomeroy; Seán O Flynn; Mihai Grigoras; Terence P Murphy; Alexandra I Stavrakis; Fiachra E Rowan
Journal:  J Clin Orthop Trauma       Date:  2022-09-13

7.  Cup position alone does not predict risk of dislocation after hip arthroplasty.

Authors:  Christina I Esposito; Brian P Gladnick; Yuo-Yu Lee; Stephen Lyman; Timothy M Wright; David J Mayman; Douglas E Padgett
Journal:  J Arthroplasty       Date:  2014-07-11       Impact factor: 4.757

8.  Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series.

Authors:  Ji-Hyo Hwang; Sang-Min Kim; Kwang-Jun Oh; Yeesuk Kim
Journal:  Int Orthop       Date:  2017-10-07       Impact factor: 3.075

9.  [Research and application of artificial intelligence based three-dimensional preoperative planning system for total hip arthroplasty].

Authors:  Dong Wu; Xingyu Liu; Yiling Zhang; Jiying Chen; Peifu Tang; Wei Chai
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-09-15

10.  A multimodal approach prevents instability after total hip arthroplasty: A 1 year follow-up prospective study.

Authors:  Omar Amado; Maria Bautista; Jose Moore; Guillermo Bonilla; Nicolas Jimenez; Adolfo Llinás
Journal:  J Clin Orthop Trauma       Date:  2016-11-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.