Novel methods reveal that parallelism contributes to the functional vertical slot dimension in ceramic and metal brackets.

Matthew Silver, Alfred C Griffin, Lauren Azzopardi, Mohammed I Masoud, Oluwabunmi Tokede, Alfred C Griffin.   

Abstract

OBJECTIVES: : To validate a novel method for measuring the clinically relevant bracket slot and use these methods to test the hypothesis that various metal injection molded (MIM) and esthetic ceramic injection molded (CIM) brackets have a bracket slot accuracy within 1 mil (0.001") of their reported slot dimension.
MATERIALS AND METHODS: : A Nikon iNEXIV-VMA-2520 laser microscope was used to measure slots of six series of CIM brackets and two series of MIM brackets via a vision measuring system of 256 gray levels to capture each edge of the slot, largely taking out human subjectivity. This system had a maximum permissible error of 2 + 8 L/1000 μm with a point resolution of 0.1 μm and was estimated to be more accurate than previous methods by a factor of 10. The video image for each bracket was autofocused by a blinded operator, and 40 point-to-line measurements were calculated along the clinical slot and averaged.
RESULTS: : Vertical slot dimension varied from series to series and within the series of brackets. Three of six CIM and two of three MIM brackets had a statistically significant mean slot size 0.001 inches larger than reported. The reported precision of these CIM brackets, as determined from standard deviation, varied from series to series.
CONCLUSIONS: : A novel system that incorporates parallelism into analysis of vertical bracket slot dimension was described. When the entire clinically relevant slot was considered, MIM and CIM brackets had similar precision but were significantly oversized, with contribution from a nonparallel, likely diverging, vertical slot dimension.

Entities:  

Keywords:  Brackets; Injection molding; Parallelism; Slot

Mesh:

Substances:

Year:  2018        PMID: 30124321      PMCID: PMC8174069          DOI: 10.2319/010518-10.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  6 in total

1.  An evaluation of slot size in orthodontic brackets--are standards as expected?

Authors:  A C Cash; S A Good; R V Curtis; F McDonald
Journal:  Angle Orthod       Date:  2004-08       Impact factor: 2.079

2.  Assessment of slot sizes in self-ligating brackets using electron microscopy.

Authors:  Nidhi B Bhalla; Sarah A Good; Fraser McDonald; Martyn Sherriff; Alex C Cash
Journal:  Aust Orthod J       Date:  2010-05

3.  Actual versus theoretical torsional play in conventional and self-ligating bracket systems.

Authors:  Michel Dalstra; Henrik Eriksen; Chiara Bergamini; Birte Melsen
Journal:  J Orthod       Date:  2015-01-14

4.  Orthodontic bracket slot dimensions as measured from entire bracket series.

Authors:  Paul Brown; Warren Wagner; Hyden Choi
Journal:  Angle Orthod       Date:  2014-09-29       Impact factor: 2.079

5.  Evaluation of esthetic brackets' resistance to torsional forces from the archwire.

Authors:  Clarice Nishio; Alvaro de Moraes Mendes; Marco Antonio de Oliveira Almeida; Eiji Tanaka; Kazuo Tanne; Carlos Nelson Elias
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-01       Impact factor: 2.650

Review 6.  Torque expression in stainless steel orthodontic brackets. A systematic review.

Authors:  Amy Archambault; Ryan Lacoursiere; Hisham Badawi; Paul W Major; Jason Carey; Carlos Flores-Mir
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

  6 in total
  1 in total

1.  Comparison of slot sizes and parallelism of metal brackets manufactured through metal injection molding and computerized numerical control.

Authors:  Jae-Sung Park; In-Tae Song; Jae-Hee Bae; Soo-Min Gil; Kyung-Hwa Kang
Journal:  Korean J Orthod       Date:  2020-11-25       Impact factor: 1.372

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.