Literature DB >> 19121499

Evaluation of esthetic brackets' resistance to torsional forces from the archwire.

Clarice Nishio1, Alvaro de Moraes Mendes, Marco Antonio de Oliveira Almeida, Eiji Tanaka, Kazuo Tanne, Carlos Nelson Elias.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the resistance to deformation or fracture of esthetic brackets produced by archwire torsion.
METHODS: Six types of maxillary right central incisor brackets were analyzed: traditional ceramic brackets (cer); ceramic brackets reinforced with a stainless steel slot (cer/ss); ceramic brackets reinforced with a gold slot (cer/gold); traditional polycarbonate brackets (poly); polycarbonate brackets reinforced with a stainless steel slot (poly/ss); and polycarbonate brackets reinforced with ceramic fillers and a stainless steel slot (poly/cer/ss). Stainless steel wire segments were used, and the testing instrument (Emic DL 10000, São José do Rio Preto, PR, Brazil) was moved at a rate of 1 inch per minute to generate the wire torsion.
RESULTS: The brackets showed deformation or fracture resistance values (gf x mm) in decreasing order as follows: cer/ss (3528.1 +/- 516.6), cer/gold (2858.7 +/- 611.6), cer (2424.0 +/- 352.1), poly/cer/ss (2279.5 +/- 174.5), poly/ss (2142.0 +/- 275.7), and poly (1463.6 +/- 193.3). The cer/ss ceramic brackets showed the greatest statistically significant (P <0.01) values of resistance to fracture, and the poly brackets had the lowest statistically significant (P <0.01) values of resistance to deformation. The cer brackets showed no significant differences (P >0.01) from the cer/gold, the poly/cer/ss, and the poly/ss brackets.
CONCLUSIONS: This suggested that the stainless steel slot might enhance resistance to deformation or fracture, although gold slots and ceramic fillers are ineffective for reinforcing esthetic brackets.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19121499     DOI: 10.1016/j.ajodo.2007.04.036

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Novel methods reveal that parallelism contributes to the functional vertical slot dimension in ceramic and metal brackets.

Authors:  Matthew Silver; Alfred C Griffin; Lauren Azzopardi; Mohammed I Masoud; Oluwabunmi Tokede; Alfred C Griffin
Journal:  Angle Orthod       Date:  2018-08-20       Impact factor: 2.079

2.  Comparative assessment of clinical performance of esthetic bracket materials.

Authors:  Nikolaos Gkantidis; Spiros Zinelis; Marina Karamolegkou; Theodore Eliades; Nikolaos Topouzelis
Journal:  Angle Orthod       Date:  2012-01-09       Impact factor: 2.079

3.  Evaluation of mechanical properties of esthetic brackets.

Authors:  Shigeyuki Matsui; Eisaku Umezaki; Daigo Komazawa; Yuichiro Otsuka; Naoto Suda
Journal:  J Dent Biomech       Date:  2015-02-26
  3 in total