| Literature DB >> 33144529 |
Jae-Sung Park1, In-Tae Song2, Jae-Hee Bae2, Soo-Min Gil2, Kyung-Hwa Kang2.
Abstract
OBJECTIVE: To investigate and compare the slot sizes and parallelism of metal injection molding (MIM) and computerized numerical control (CNC) brackets.Entities:
Keywords: Computerized numerical control; Metal injection molding; Slot parallelism; Slot size
Year: 2020 PMID: 33144529 PMCID: PMC7642229 DOI: 10.4041/kjod.2020.50.6.401
Source DB: PubMed Journal: Korean J Orthod Impact factor: 1.372
Selected metal injection molding (MIM) and computerized numerical control (CNC) bracket series (four each)
| Bracket series | Manufacturer | |
|---|---|---|
| MIM | Di MIM® mini Twin | Ortho Organizers, USA |
| Mini Diamond Roth | Ormco, USA | |
| GeminiTM MBT | 3M UnitekTM, USA | |
| Formula R Roth | Tomy, Japan | |
| CNC | EconolineTM MBT | Adenta®, Germany |
| Legend mini MBT | GC Orthodontics, Japan | |
| Crown miniTM MBT | Adenta®, Germany | |
| EvolveTM MBT | DB Orthodontics, UK |
Information of the manufacture’s specification was acquired from their internet homepages or from published sales literature.
Figure 1Optical microscope used for the measurements (XTCam-D310M; Mitutoyo, Kanagawa, Japan).
Figure 2Measuring points on the bracket (A: slot top, B: slot base).
Slot sizes of the selected metal injection molding (MIM) and computerized numerical control (CNC) bracket series
| Bracket series | n | Mean ± standard | Minimum | Maximum | Lower 95% CI | Upper 95% CI | Tukey |
|---|---|---|---|---|---|---|---|
| MIM | |||||||
| Di MIM | 100 | 0.02428 ± 0.00123 | 0.02177 | 0.02818 | 0.02410 | 0.02446 | D |
| Mini Diamond | 100 | 0.02283 ± 0.00080 | 0.02055 | 0.02547 | 0.02275 | 0.02298 | B |
| Gemini | 100 | 0.02289 ± 0.00046 | 0.02157 | 0.02440 | 0.02283 | 0.02296 | B |
| Formula R | 100 | 0.02299 ± 0.00056 | 0.02169 | 0.02468 | 0.02292 | 0.02308 | B |
| CNC | |||||||
| Econoline | 100 | 0.02317 ± 0.00068 | 0.02181 | 0.02511 | 0.02308 | 0.02327 | C |
| Legend | 100 | 0.02295 ± 0.00049 | 0.02181 | 0.02417 | 0.02289 | 0.02303 | B |
| Crown | 100 | 0.02298 ± 0.00089 | 0.02027 | 0.02559 | 0.02286 | 0.02311 | B |
| Evolve | 100 | 0.02257 ± 0.00092 | 0.02015 | 0.02622 | 0.02245 | 0.02271 | A |
All the data were measured in inches.
One-way ANOVA was performed due to the normality of the data (p = 0.000, < 0.05).
The results showed statistical differences between the groups (p < 0.05).
Tukey’s post-hoc test was performed; subgroups for α = 0.05.
The different characters represent the statistical differences.
CI, Confidence interval.
Figure 3Graphical representation of the slot sizes.
Differences in the slot top to slot base measurements and parallelism of the slot walls
| Bracket series | Slot top | Slot base | Difference from | Tukey test | |
|---|---|---|---|---|---|
| MIM | |||||
| Di MIM | 0.02504 ± 0.00111 | 0.02353 ± 0.00088 | 0.00151 ± 0.00014 | 0.000 | E |
| Mini Diamond | 0.02337 ± 0.00071 | 0.02235 ± 0.00051 | 0.00102 ± 0.00009 | 0.000 | D |
| Gemini | 0.02313 ± 0.00040 | 0.02266 ± 0.00038 | 0.00048 ± 0.00006 | 0.000 | C |
| Formula R | 0.02316 ± 0.00059 | 0.02284 ± 0.00048 | 0.00032 ± 0.00008 | 0.000 | B |
| CNC | |||||
| Econoline | 0.02347 ± 0.00068 | 0.02289 ± 0.00053 | 0.00059 ± 0.00009 | 0.000 | C |
| Legend | 0.02309 ± 0.00044 | 0.02283 ± 0.00051 | 0.00027 ± 0.00007 | 0.000 | B |
| Crown | 0.02335 ± 0.00088 | 0.02263 ± 0.00075 | 0.00071 ± 0.00012 | 0.000 | C |
| Evolve | 0.02257 ± 0.00085 | 0.02259 ± 0.00099 | 0.00002 ± 0.00001 | 0.902 | A |
Data are represented as mean ± standard deviation.
All the data were measured in inches.
Independent t-tests were performed between the slot top and slot base because of the normality of the data.
Slot parallelism could be interpreted from the p-values.
One-way ANOVA was performed due to the normality of the data (p = 0.000, <0.05).
The results showed statistical differences between the groups (p < 0.05).
Tukey’s post-hoc test was performed; subgroups for α = 0.05.
The different characters represent the statistical differences.
***p < 0.001.
Figure 4Graphical representation of the differences in the measurements from the slot top to the slot base.
Oversized slot errors with respect to the manufacturer’s specifications
| Bracket series | Mean difference from specification | Mean slot |
|---|---|---|
| MIM | ||
| Di MIM | 0.02428–0.022 | +0.00228 |
| Mini Diamond | 0.02283–0.022 | +0.00083 |
| Gemini | 0.02289–0.022 | +0.00089 |
| Formula R | 0.02299–0.022 | +0.00099 |
| CNC | ||
| Econoline | 0.02317–0.022 | +0.00117 |
| Legend | 0.02295–0.022 | +0.00095 |
| Crown | 0.02298–0.022 | +0.00098 |
| Evolve | 0.02257–0.022 | +0.00057 |
All the data were measured in inches.
MIM, Metal injection molding; CNC, computerized numerical control.