Literature DB >> 29993864

MR Performance in the Presence of a Radio Frequency-Penetrable Positron Emission Tomography (PET) Insert for Simultaneous PET/MRI.

Brian J Lee, Alexander M Grant, Chen-Ming Chang, Ronald D Watkins, Gary H Glover, Craig S Levin.   

Abstract

Despite the great promise of integrated positron emission tomography (PET)/magnetic resonance (MR) imaging to add molecular information to anatomical and functional MR, its potential impact in medicine is diminished by a very high cost, limiting its dissemination. An RF-penetrable PET ring that can be inserted into any existing MR system has been developed to address this issue. Employing optical signal transmission along with battery power enables the PET ring insert to electrically float with respect to the MR system. Then, inter-modular gaps of the PET ring allow the RF transmit field from the standard built-in body coil to penetrate into the PET fields-of-view (FOV) with some attenuation that can be compensated for. MR performance, including RF noise, magnetic susceptibility, RF penetrability through and $B_{1}$ uniformity within the PET insert, and MR image quality, were analyzed with and without the PET ring present. The simulated and experimentally measured RF field attenuation factors with the PET ring present were -2.7 and -3.2 dB, respectively. The magnetic susceptibility effect (0.063 ppm) and noise emitted from the PET ring in the MR receive channel were insignificant. $B_{1}$ homogeneity of a spherical agar phantom within the PET ring FOV dropped by 8.4% and MR image SNR was reduced by 3.5 and 4.3 dB with the PET present for gradient-recalled echo and fast-spin echo, respectively. This paper demonstrates, for the first time, an RF-penetrable PET insert comprising a full ring of operating detectors that achieves simultaneous PET/MR using the standard built-in body coil as the RF transmitter.

Entities:  

Mesh:

Year:  2018        PMID: 29993864      PMCID: PMC6195123          DOI: 10.1109/TMI.2018.2815620

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  33 in total

1.  Correction of MR kappa-space data corrupted by spike noise.

Authors:  Y H Kao; J R MacFall
Journal:  IEEE Trans Med Imaging       Date:  2000-07       Impact factor: 10.048

2.  EPI image reconstruction with correction of distortion and signal losses.

Authors:  Guoxiang Liu; Seiji Ogawa
Journal:  J Magn Reson Imaging       Date:  2006-09       Impact factor: 4.813

3.  A Digital Preclinical PET/MRI Insert and Initial Results.

Authors:  Bjoern Weissler; Pierre Gebhardt; Peter M Dueppenbecker; Jakob Wehner; David Schug; Christoph W Lerche; Benjamin Goldschmidt; Andre Salomon; Iris Verel; Edwin Heijman; Michael Perkuhn; Dirk Heberling; Rene M Botnar; Fabian Kiessling; Volkmar Schulz
Journal:  IEEE Trans Med Imaging       Date:  2015-04-29       Impact factor: 10.048

4.  MR-compatibility assessment of the first preclinical PET-MRI insert equipped with digital silicon photomultipliers.

Authors:  J Wehner; B Weissler; P M Dueppenbecker; P Gebhardt; B Goldschmidt; D Schug; F Kiessling; V Schulz
Journal:  Phys Med Biol       Date:  2015-02-16       Impact factor: 3.609

5.  Principles of PET/MR Imaging.

Authors:  Jonathan A Disselhorst; Ilja Bezrukov; Armin Kolb; Christoph Parl; Bernd J Pichler
Journal:  J Nucl Med       Date:  2014-05-12       Impact factor: 10.057

6.  Characterization methods for comprehensive evaluations of shielding materials used in an MRI.

Authors:  Nicolas Gross-Weege; Thomas Dey; Pierre Gebhardt; David Schug; Bjoern Weissler; Volkmar Schulz
Journal:  Med Phys       Date:  2018-02-26       Impact factor: 4.071

7.  A 31-channel MR brain array coil compatible with positron emission tomography.

Authors:  Christin Y Sander; Boris Keil; Daniel B Chonde; Bruce R Rosen; Ciprian Catana; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-07-07       Impact factor: 4.668

8.  Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner.

Authors:  Bo J Peng; Jeffrey H Walton; Simon R Cherry; Jacob Willig-Onwuachi
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

Review 9.  Clinical applications of PET/MRI: current status and future perspectives.

Authors:  Felix Nensa; Karsten Beiderwellen; Philipp Heusch; Axel Wetter
Journal:  Diagn Interv Radiol       Date:  2014 Sep-Oct       Impact factor: 2.630

10.  Readout strategy of an electro-optical coupled PET detector for time-of-flight PET/MRI.

Authors:  M F Bieniosek; P D Olcott; C S Levin
Journal:  Phys Med Biol       Date:  2013-09-24       Impact factor: 3.609

View more
  5 in total

1.  3D Auto-Context-Based Locality Adaptive Multi-Modality GANs for PET Synthesis.

Authors:  Yan Wang; Luping Zhou; Biting Yu; Lei Wang; Chen Zu; David S Lalush; Weili Lin; Xi Wu; Jiliu Zhou; Dinggang Shen
Journal:  IEEE Trans Med Imaging       Date:  2018-11-29       Impact factor: 10.048

2.  Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI.

Authors:  Brian J Lee; Ronald D Watkins; Keum Sil Lee; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2018-09-09       Impact factor: 4.668

3.  Performance study of a radio-frequency field-penetrable PET insert for simultaneous PET/MRI.

Authors:  Chen-Ming Chang; Brian J Lee; Alexander M Grant; Andrew N Groll; Craig S Levin
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-07-03

4.  Evaluation of the radiofrequency performance of a wide-bore 1.5 T positron emission tomography/magnetic resonance imaging body coil for radiotherapy planning.

Authors:  Woutjan Branderhorst; Bart R Steensma; Casper Beijst; Erik R Huijing; Cezar Alborahal; Edwin Versteeg; Bjoern Weissler; David Schug; Pierre Gebhardt; Nicolas Gross-Weege; Florian Mueller; Karl Krueger; Thomas Dey; Harald Radermacher; Oliver Lips; Jan Lagendijk; Volkmar Schulz; Hugo W A M de Jong; Dennis W J Klomp
Journal:  Phys Imaging Radiat Oncol       Date:  2020-12-23

5.  Design and system evaluation of a dual-panel portable PET (DP-PET).

Authors:  Tianyi Zeng; Jiaxu Zheng; Xinyuan Xia; Xin Chen; Beien Wang; Shuangyue Zhang; Adam Chandler; Tuoyu Cao; Lingzhi Hu; Qun Chen; Xu Chu
Journal:  EJNMMI Phys       Date:  2021-06-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.