Literature DB >> 24061218

Readout strategy of an electro-optical coupled PET detector for time-of-flight PET/MRI.

M F Bieniosek1, P D Olcott, C S Levin.   

Abstract

Combining PET with MRI in a single system provides clinicians with complementary molecular and anatomical information. However, existing integrated PET/MRI systems do not have time-of-flight (ToF) PET capabilities. This work describes an MRI-compatible front-end electronic system with ToF capabilities. The approach employs a fast arrival-time pickoff comparator to digitize the timing information, and a laser diode to drive a 10 m fiber-optic cable to optically transmit asynchronous timing information to a photodiode receiver readout system. The FWHM jitter of the comparator and this electo-optical link is 11.5 ps in response to a fast digital pulse. When configured with LYSO scintillation crystals and Hamamatsu MPPC silicon photo-multipliers the comparator and electro-optical link achieved a 511 keV coincidence time resolution of 254.7 ps +/- 8.0 ps FWHM with 3 × 3 × 20 mm(3) crystals and 166.5 +/- 2.5 ps FWHM with 3 × 3 × 5 mm(3) crystals.

Entities:  

Mesh:

Year:  2013        PMID: 24061218      PMCID: PMC3903396          DOI: 10.1088/0031-9155/58/20/7227

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  LaBr(3):Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time.

Authors:  Dennis R Schaart; Stefan Seifert; Ruud Vinke; Herman T van Dam; Peter Dendooven; Herbert Löhner; Freek J Beekman
Journal:  Phys Med Biol       Date:  2010-03-19       Impact factor: 3.609

2.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

3.  Benefit of time-of-flight in PET: experimental and clinical results.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

Review 4.  PET and MRI in cardiac imaging: from validation studies to integrated applications.

Authors:  Stephan G Nekolla; Axel Martinez-Moeller; Antti Saraste
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 5.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

6.  The current state, challenges and perspectives of MR-PET.

Authors:  Hans Herzog; Uwe Pietrzyk; N Jon Shah; Karl Ziemons
Journal:  Neuroimage       Date:  2009-10-21       Impact factor: 6.556

7.  PET/MRI: paving the way for the next generation of clinical multimodality imaging applications.

Authors:  Bernd J Pichler; Armin Kolb; Thomas Nägele; Heinz-Peter Schlemmer
Journal:  J Nucl Med       Date:  2010-02-11       Impact factor: 10.057

8.  Time-of-flight positron emission tomography: status relative to conventional PET.

Authors:  T F Budinger
Journal:  J Nucl Med       Date:  1983-01       Impact factor: 10.057

9.  Simultaneous PET and MR imaging.

Authors:  Y Shao; S R Cherry; K Farahani; K Meadors; S Siegel; R W Silverman; P K Marsden
Journal:  Phys Med Biol       Date:  1997-10       Impact factor: 3.609

10.  The timing resolution of scintillation-detector systems: Monte Carlo analysis.

Authors:  Woon-Seng Choong
Journal:  Phys Med Biol       Date:  2009-10-09       Impact factor: 3.609

View more
  3 in total

1.  Analog electro-optical readout of SiPMs achieves fast timing required for time-of-flight PET/MR.

Authors:  M F Bieniosek; C S Levin
Journal:  Phys Med Biol       Date:  2015-04-23       Impact factor: 3.609

Review 2.  PET/MRI: Technical Challenges and Recent Advances.

Authors:  Jin Ho Jung; Yong Choi; Ki Chun Im
Journal:  Nucl Med Mol Imaging       Date:  2016-01-26

3.  MR Performance in the Presence of a Radio Frequency-Penetrable Positron Emission Tomography (PET) Insert for Simultaneous PET/MRI.

Authors:  Brian J Lee; Alexander M Grant; Chen-Ming Chang; Ronald D Watkins; Gary H Glover; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2018-03-13       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.