Literature DB >> 25935031

A Digital Preclinical PET/MRI Insert and Initial Results.

Bjoern Weissler, Pierre Gebhardt, Peter M Dueppenbecker, Jakob Wehner, David Schug, Christoph W Lerche, Benjamin Goldschmidt, Andre Salomon, Iris Verel, Edwin Heijman, Michael Perkuhn, Dirk Heberling, Rene M Botnar, Fabian Kiessling, Volkmar Schulz.   

Abstract

Combining Positron Emission Tomography (PET) with Magnetic Resonance Imaging (MRI) results in a promising hybrid molecular imaging modality as it unifies the high sensitivity of PET for molecular and cellular processes with the functional and anatomical information from MRI. Digital Silicon Photomultipliers (dSiPMs) are the digital evolution in scintillation light detector technology and promise high PET SNR. DSiPMs from Philips Digital Photon Counting (PDPC) were used to develop a preclinical PET/RF gantry with 1-mm scintillation crystal pitch as an insert for clinical MRI scanners. With three exchangeable RF coils, the hybrid field of view has a maximum size of 160 mm × 96.6 mm (transaxial × axial). 0.1 ppm volume-root-mean-square B 0-homogeneity is kept within a spherical diameter of 96 mm (automatic volume shimming). Depending on the coil, MRI SNR is decreased by 13% or 5% by the PET system. PET count rates, energy resolution of 12.6% FWHM, and spatial resolution of 0.73 mm (3) (isometric volume resolution at isocenter) are not affected by applied MRI sequences. PET time resolution of 565 ps (FWHM) degraded by 6 ps during an EPI sequence. Timing-optimized settings yielded 260 ps time resolution. PET and MR images of a hot-rod phantom show no visible differences when the other modality was in operation and both resolve 0.8-mm rods. Versatility of the insert is shown by successfully combining multi-nuclei MRI ((1)H/(19)F) with simultaneously measured PET ((18)F-FDG). A longitudinal study of a tumor-bearing mouse verifies the operability, stability, and in vivo capabilities of the system. Cardiac- and respiratory-gated PET/MRI motion-capturing (CINE) images of the mouse heart demonstrate the advantage of simultaneous acquisition for temporal and spatial image registration.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25935031     DOI: 10.1109/TMI.2015.2427993

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  18 in total

1.  Optical delay encoding for fast timing and detector signal multiplexing in PET.

Authors:  Alexander M Grant; Craig S Levin
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Small animal, positron emission tomography-magnetic resonance imaging system based on a clinical magnetic resonance imaging scanner: evaluation of basic imaging performance.

Authors:  Raymond R Raylman; Patrick Ledden; Alexander V Stolin; Bob Hou; Ganghadar Jaliparthi; Peter F Martone
Journal:  J Med Imaging (Bellingham)       Date:  2018-09-08

Review 3.  From simultaneous to synergistic MR-PET brain imaging: A review of hybrid MR-PET imaging methodologies.

Authors:  Zhaolin Chen; Sharna D Jamadar; Shenpeng Li; Francesco Sforazzini; Jakub Baran; Nicholas Ferris; Nadim Jon Shah; Gary F Egan
Journal:  Hum Brain Mapp       Date:  2018-08-04       Impact factor: 5.038

Review 4.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

5.  Optimization of a depth of interaction encoding PET block detector for a PET/MRI insert.

Authors:  Aaron R Selfridge; Simon R Cherry; Martin S Judenhofer
Journal:  Phys Med Biol       Date:  2018-12-06       Impact factor: 3.609

6.  Performance study of a radio-frequency field-penetrable PET insert for simultaneous PET/MRI.

Authors:  Chen-Ming Chang; Brian J Lee; Alexander M Grant; Andrew N Groll; Craig S Levin
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-07-03

7.  MR Performance in the Presence of a Radio Frequency-Penetrable Positron Emission Tomography (PET) Insert for Simultaneous PET/MRI.

Authors:  Brian J Lee; Alexander M Grant; Chen-Ming Chang; Ronald D Watkins; Gary H Glover; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2018-03-13       Impact factor: 10.048

8.  Performance evaluation of the mouse version of the LabPET II PET scanner.

Authors:  Émilie Gaudin; Christian Thibaudeau; Louis Arpin; Jean-Daniel Leroux; Maxime Toussaint; Jean-Francois Beaudoin; Jules Cadorette; Maxime Paillé; Catherine M Pepin; Konin Koua; Jonathan Bouchard; Nicolas Viscogliosi; Caroline Paulin; Réjean Fontaine; Roger Lecomte
Journal:  Phys Med Biol       Date:  2021-03-09       Impact factor: 3.609

9.  Initial PET performance evaluation of a preclinical insert for PET/MRI with digital SiPM technology.

Authors:  David Schug; Christoph Lerche; Bjoern Weissler; Pierre Gebhardt; Benjamin Goldschmidt; Jakob Wehner; Peter Michael Dueppenbecker; Andre Salomon; Patrick Hallen; Fabian Kiessling; Volkmar Schulz
Journal:  Phys Med Biol       Date:  2016-03-17       Impact factor: 3.609

10.  FPGA-based RF interference reduction techniques for simultaneous PET-MRI.

Authors:  P Gebhardt; J Wehner; B Weissler; R Botnar; P K Marsden; V Schulz
Journal:  Phys Med Biol       Date:  2016-04-06       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.