Literature DB >> 11055782

Correction of MR kappa-space data corrupted by spike noise.

Y H Kao1, J R MacFall.   

Abstract

Magnetic resonance images are reconstructed from digitized raw data, which are collected in the spatial-frequency domain (also called kappa-space). Occasionally, single or multiple data points in the k-space data are corrupted by spike noise, causing striation artifacts in images. Thresholding methods for detecting corrupted data points can fail because of small alterations, especially for data points in the low spatial frequency area where the k-space variation is large. Restoration of corrupted data points using interpolations of neighboring pixels can give incorrect results. We propose a Fourier transform method for detecting and restoring corrupted data points using a window filter derived from the striation-artifact structure in an image or an intermediate domain. The method provides an analytical solution for the alteration at each corrupted data point. It can effectively restore corrupted kappa-space data, removing striation artifacts in images, provided that the following three conditions are satisfied. First, a region of known signal distribution (for example, air background) is visible in either the image or the intermediate domain so that it can be selected using a window filter. Second, multiple spikes are separated by the full-width at half-maximum of the point spread function for the window filter. Third, the magnitude of a spike is larger than the minimum detectable value determined by the window filter and the standard deviation of kappa-space random noise.

Mesh:

Year:  2000        PMID: 11055782     DOI: 10.1109/42.875184

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  POCS-enhanced correction of motion artifacts in parallel MRI.

Authors:  Alexey A Samsonov; Julia Velikina; Youngkyoo Jung; Eugene G Kholmovski; Chris R Johnson; Walter F Block
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

2.  MR Performance in the Presence of a Radio Frequency-Penetrable Positron Emission Tomography (PET) Insert for Simultaneous PET/MRI.

Authors:  Brian J Lee; Alexander M Grant; Chen-Ming Chang; Ronald D Watkins; Gary H Glover; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2018-03-13       Impact factor: 10.048

3.  Using the robust principal component analysis algorithm to remove RF spike artifacts from MR images.

Authors:  Adrienne E Campbell-Washburn; David Atkinson; Zoltan Nagy; Rachel W Chan; Oliver Josephs; Mark F Lythgoe; Roger J Ordidge; David L Thomas
Journal:  Magn Reson Med       Date:  2015-07-20       Impact factor: 4.668

4.  Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction.

Authors:  N Koonjoo; B Zhu; G Cody Bagnall; D Bhutto; M S Rosen
Journal:  Sci Rep       Date:  2021-04-15       Impact factor: 4.379

5.  A New Phased-Array Magnetic Resonance Imaging Receive-Only Coil for HBO2 Studies.

Authors:  Azma Mareyam; Erik Shank; Lawrence L Wald; Michael K Qin; Giorgio Bonmassar
Journal:  Sensors (Basel)       Date:  2022-08-14       Impact factor: 3.847

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.