Literature DB >> 20009193

Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner.

Bo J Peng1, Jeffrey H Walton, Simon R Cherry, Jacob Willig-Onwuachi.   

Abstract

A positron emission tomography (PET) system or 'insert' has been constructed for placement and operation in the bore of a small animal magnetic resonance imaging (MRI) scanner to allow simultaneous MR and PET imaging. The insert contains electronics, components with a variety of magnetic properties and large continuous sheets of metal--all characteristics of an object that should, by conventional wisdom, never be placed in the bore of an MR scanner, especially near the imaging volume. There are a variety of ways the two systems might be expected to interact that could negatively impact the performance of either or both. In this article, the interaction mechanisms, particularly the impact of the PET insert and shielding on MR imaging, are defined and explored. Additionally, some of the difficulties in quantifying errors introduced into the MR images as a result of the presence of the PET components are demonstrated. Several different approaches are used to characterize image artifacts and determine optimal placement of the shielding. Data are also presented that suggest ways the shielding could be modified to reduce errors and enable placement closer to the isocenter of the magnet.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20009193      PMCID: PMC2825890          DOI: 10.1088/0031-9155/55/1/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  25 in total

Review 1.  Advanced imaging concepts: a pictorial glossary of CT and MRI technology.

Authors:  A S Tidwell; J C Jones
Journal:  Clin Tech Small Anim Pract       Date:  1999-05

2.  A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner.

Authors:  R B Slates; K Farahani; Y Shao; P K Marsden; J Taylor; P E Summers; S Williams; J Beech; S R Cherry
Journal:  Phys Med Biol       Date:  1999-08       Impact factor: 3.609

3.  Towards MRI guided surgical manipulator.

Authors:  K Chinzei; K Miller
Journal:  Med Sci Monit       Date:  2001 Jan-Feb

4.  Anatomical landmarks for image registration in frameless stereotactic neuronavigation.

Authors:  Stefan Wolfsberger; K Rössler; R Regatschnig; K Ungersböck
Journal:  Neurosurg Rev       Date:  2002-03       Impact factor: 3.042

5.  Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

Authors:  Ciprian Catana; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

6.  Point/counterpoint. Simultaneous PET/MR will replace PET/CT as the molecular multimodality imaging platform of choice.

Authors:  Habib Zaidi; Osama Mawlawi; Colin G Orton
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

Review 7.  Multimodality imaging of structure and function.

Authors:  D W Townsend
Journal:  Phys Med Biol       Date:  2008-01-28       Impact factor: 3.609

8.  Simultaneous PET and MR imaging.

Authors:  Y Shao; S R Cherry; K Farahani; K Meadors; S Siegel; R W Silverman; P K Marsden
Journal:  Phys Med Biol       Date:  1997-10       Impact factor: 3.609

Review 9.  Whole-body imaging with PET/MRI.

Authors:  J Gaa; E J Rummeny; M D Seemann
Journal:  Eur J Med Res       Date:  2004-06-30       Impact factor: 2.175

Review 10.  Recent developments in PET detector technology.

Authors:  Tom K Lewellen
Journal:  Phys Med Biol       Date:  2008-08-11       Impact factor: 3.609

View more
  9 in total

Review 1.  PET/MRI: current state of the art and future potential for cardiovascular applications.

Authors:  Nebiyu Adenaw; Michael Salerno
Journal:  J Nucl Cardiol       Date:  2013-12       Impact factor: 5.952

Review 2.  Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer's perspective.

Authors:  Antonis Kalemis; Bénédicte M A Delattre; Susanne Heinzer
Journal:  MAGMA       Date:  2012-08-07       Impact factor: 2.310

Review 3.  PET/MRI: Technical Challenges and Recent Advances.

Authors:  Jin Ho Jung; Yong Choi; Ki Chun Im
Journal:  Nucl Med Mol Imaging       Date:  2016-01-26

4.  New shielding configurations for a simultaneous PET/MRI scanner at 7T.

Authors:  Bo J Peng; Yibao Wu; Simon R Cherry; Jeffrey H Walton
Journal:  J Magn Reson       Date:  2013-11-14       Impact factor: 2.229

5.  Simultaneous PET/MR imaging with a radio frequency-penetrable PET insert.

Authors:  Alexander M Grant; Brian J Lee; Chen-Ming Chang; Craig S Levin
Journal:  Med Phys       Date:  2017-01       Impact factor: 4.071

6.  Low eddy current RF shielding enclosure designs for 3T MR applications.

Authors:  Brian J Lee; Ronald D Watkins; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2017-06-06       Impact factor: 4.668

7.  MR Performance in the Presence of a Radio Frequency-Penetrable Positron Emission Tomography (PET) Insert for Simultaneous PET/MRI.

Authors:  Brian J Lee; Alexander M Grant; Chen-Ming Chang; Ronald D Watkins; Gary H Glover; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2018-03-13       Impact factor: 10.048

8.  Design and system evaluation of a dual-panel portable PET (DP-PET).

Authors:  Tianyi Zeng; Jiaxu Zheng; Xinyuan Xia; Xin Chen; Beien Wang; Shuangyue Zhang; Adam Chandler; Tuoyu Cao; Lingzhi Hu; Qun Chen; Xu Chu
Journal:  EJNMMI Phys       Date:  2021-06-12

9.  FPGA-based RF interference reduction techniques for simultaneous PET-MRI.

Authors:  P Gebhardt; J Wehner; B Weissler; R Botnar; P K Marsden; V Schulz
Journal:  Phys Med Biol       Date:  2016-04-06       Impact factor: 3.609

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.