Literature DB >> 30911706

Performance study of a radio-frequency field-penetrable PET insert for simultaneous PET/MRI.

Chen-Ming Chang1, Brian J Lee2, Alexander M Grant3, Andrew N Groll4, Craig S Levin5.   

Abstract

Hybrid positron emission tomography (PET)/magnetic resonance imaging (MRI) has risen to the cutting edge of medical imaging technology as it allows simultaneous acquisition of structural, functional and molecular information of the patient. A PET insert that can be installed into existing MR systems can in principle reduce the cost barriers for an existing MR site to achieve simultaneous PET/MRI compared to procuring an integrated PET+MRI system. The PET insert systems developed so far for PET/MRI require the RF transmitter coil to reside inside the PET ring as those PET inserts block the RF fields from the MRI system. Here we report for the first time on the performance of a full-ring brain-sized "RF-penetrable" PET insert we have recently completed. This insert allows the RF fields generated by the built-in body coil to penetrate the PET ring. The PET insert comprises a ring of 16 detector modules employing electro-optical coupled signal transmission and a multiplexing framework based on compressed sensing. Energy resolution, coincidence timing resolution (CTR), photopeak position, and coincidence count rate were acquired outside and inside a 3-Tesla MRI system under simultaneous acquisition to evaluate the impact of MRI on the PET performance. Coincidence count rate performance was evaluated by acquiring a cylinder source with high initial activity decaying over time. Tomographic imaging of two phantoms, a custom 6.5-cm diameter resolution phantom with hot rods of four different sizes (2.8 mm, 3.2 mm, 4.2 mm, and 5.2 mm diameter) and a 3D Hoffman brain phantom, were performed to evaluate the imaging capability of the PET insert. The energy resolution at 511 keV and CTR acquired by the PET insert were 16.2±0.1% and 5.3±0.1 ns FWHM, respectively, and remained stable during MRI operation except when the EPI sequence was applied. The PET system starts to show saturation in coincidence count rate at 2.76 million photon counts per second. Most of the 2.8-mm diameter hot rods and main features of the 3D Hoffman brain phantom were resolved by the PET insert, demonstrating its high spatial resolution and capability to image a complex tracer distribution mimicking that seen in the human brain.

Entities:  

Keywords:  MRI; PET; PET/MRI; Positron emission tomography; RF-penetrable; compressed sensing; electro-optical; insert; magnetic resonance imaging

Year:  2018        PMID: 30911706      PMCID: PMC6430135          DOI: 10.1109/TRPMS.2018.2852686

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  51 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry.

Authors:  G C Wiggins; C Triantafyllou; A Potthast; A Reykowski; M Nittka; L L Wald
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

3.  Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

Authors:  Ciprian Catana; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

Review 4.  Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006.

Authors:  Johannes Czernin; Martin Allen-Auerbach; Heinrich R Schelbert
Journal:  J Nucl Med       Date:  2007-01       Impact factor: 10.057

5.  PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.

Authors:  Martin S Judenhofer; Ciprian Catana; Brian K Swann; Stefan B Siegel; Wulf-Ingo Jung; Robert E Nutt; Simon R Cherry; Claus D Claussen; Bernd J Pichler
Journal:  Radiology       Date:  2007-09       Impact factor: 11.105

Review 6.  PET/MRI system design.

Authors:  Gaspar Delso; Sibylle Ziegler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

7.  Novel electro-optical coupling technique for magnetic resonance-compatible positron emission tomography detectors.

Authors:  Peter D Olcott; Hao Peng; Craig S Levin
Journal:  Mol Imaging       Date:  2009 Mar-Apr       Impact factor: 4.488

Review 8.  Positron emission tomography/magnetic resonance imaging: the next generation of multimodality imaging?

Authors:  Bernd J Pichler; Hans F Wehrl; Armin Kolb; Martin S Judenhofer
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

9.  Simultaneous MR/PET imaging of the human brain: feasibility study.

Authors:  Heinz-Peter W Schlemmer; Bernd J Pichler; Matthias Schmand; Ziad Burbar; Christian Michel; Ralf Ladebeck; Kirstin Jattke; David Townsend; Claude Nahmias; Pradeep K Jacob; Wolf-Dieter Heiss; Claus D Claussen
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

10.  Whole-body PET/CT scanning: estimation of radiation dose and cancer risk.

Authors:  Bingsheng Huang; Martin Wai-Ming Law; Pek-Lan Khong
Journal:  Radiology       Date:  2009-02-27       Impact factor: 11.105

View more
  1 in total

1.  NEMA Performance Evaluation of CareMiBrain dedicated brain PET and Comparison with the whole-body and dedicated brain PET systems.

Authors:  Laura Moliner; Maria J Rodríguez-Alvarez; Juan V Catret; Antonio González; Víctor Ilisie; José M Benlloch
Journal:  Sci Rep       Date:  2019-10-29       Impact factor: 4.379

  1 in total