| Literature DB >> 29699518 |
Yueqin Chen1, Qian Cao1, Chunyan Xue2, Zhenping Huang3.
Abstract
BACKGROUND: To compare the results between hydroimplantation of a single-piece, acrylic foldable toric intraocular lens (IOLs) and conventional implantation using an ophthalmic viscosurgical device (OVD).Entities:
Keywords: Endothelial cell density; Hydroimplantation; Intraocular pressure; Ophthalmic viscosurgical device; Toric intraocular lens
Mesh:
Substances:
Year: 2018 PMID: 29699518 PMCID: PMC5921392 DOI: 10.1186/s12886-018-0758-6
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Implantation of a toric IOL. a The leading haptic is inserted into the capsular bag with the help of the irrigation cannula tip. b The trailing haptic is dialed and inserted into the capsular bag with the help of the small tip of a cyclodialysis spatula. c The toric IOL is rotated to its planned position directly. d A final check that the axis of the IOL is on the planned meridian and the incisions are hydrated
Demographic data at baseline
| Variables | OVD group | Hydroimplantation group | |
|---|---|---|---|
| Number | 30 | 30 | |
| Gender (M/F) | 10/15 | 11/17 | 0.480 |
| Age (years) | 69.53 ± 10.33 | 67.53 ± 9.14 | 0.513 |
| UCVA (logMAR) | 0.93 ± 0.25 | 0.81 ± 0.14 | 0.536 |
| BCVA (logMAR) | 0.67 ± 0.24 | 0.68 ± 0.22 | 0.483 |
| ECD (cells/mm2) | 2418.66 ± 322.97 | 2529.71 ± 317.50 | 0.939 |
| IOP (mmHg) | 16.15 ± 2.48 | 15.29 ± 2.31 | 0.803 |
| Refractive astigmatism (D) | 2.29 ± 0.44 | 2.10 ± 0.42 | 0.804 |
| Toric IOL model, n (%) | |||
| T3 | 9 (30.0) | 11 (36.7) | |
| T4 | 9 (30.0) | 8 (26.7) | |
| T5 | 11 (36.7) | 10 (33.3) | |
| T6 | 1 (3.3) | 1 (3.3) |
OVD ophthalmic viscosurgical device, UCVA uncorrected visual acuity, BCVA best-corrected visual acuity, ECD endothelial cell density, IOP intraocular pressure, D diopters
Fig. 2Achieved SE correction versus expected SE correction 3 months postoperatively in OVD group. (SE spherical equivalent, OVD ophthalmic viscosurgical device)
Fig. 3Achieved SE correction versus expected SE correction 3 months postoperatively in hydroimplantation group. (SE spherical equivalent)
Fig. 4Astigmatism vectors. The x-axes represent the J0 power vector (D). The y-axes represent the J45 power vector (D). (OVD ophthalmic viscosurgical device, J0 Jackson cross-cylinder, axes at 0 degree and 90 degree, J45 Jackson cross-cylinder, axes at 45 degree and 135 degree)
Mean IOP change (mmHg) postoperatively
| Time | OVD group | Hydroimplantation group | |
|---|---|---|---|
| 2 h | 16.25 ± 3.38 | 14.79 ± 3.02 | 0.830 |
| 1 day | 14.98 ± 3.52 | 14.13 ± 2.83 | 0.119 |
| 1 week | 13.45 ± 2.56 | 13.56 ± 2.35 | 0.609 |
| 1 month | 14.15 ± 1.72 | 13.47 ± 1.78 | 0.715 |
| 3 months | 14.70 ± 1.99 | 14.08 ± 1.93 | 0.981 |
IOP intraocular pressure, OVD ophthalmic viscosurgical device
Fig. 5Absolute axis rotation between the two groups three months postoperatively. (OVD = ophthalmic viscosurgical device)