| Literature DB >> 32280722 |
An-Peng Pan1, Li-Jin Wen1, Xu Shao1, Kai-Jing Zhou1, Qin-Mei Wang1, Jia Qu1, A-Yong Yu1.
Abstract
PURPOSE: To assess the efficacy and safety of a novel ophthalmic viscosurgical device-free (OVD-free) method for posterior chamber phakic intraocular lens (PIOL) implantation in myopic eyes.Entities:
Keywords: Complications; Intraocular pressure; Ophthalmic viscosurgical device-free; Phakic intraocular lens implantation
Year: 2020 PMID: 32280722 PMCID: PMC7137322 DOI: 10.1186/s40662-020-00185-4
Source DB: PubMed Journal: Eye Vis (Lond) ISSN: 2326-0254
Fig. 1An intraoperative image of Ophthalmic Viscosurgical Device-free method of phakic intraocular lens (PIOL) implantation. The red triangles show the patent irrigator, the yellow triangles indicate the patent manipulator, the anterior chamber was well maintained during the whole surgical procedure
Comparison of the two methods of phakic intraocular lens (PIOL) implantation
| OVD-free PIOL implantation | Standard PIOL implantation | |
|---|---|---|
| Number of side port(s) | 2 | 1, or none |
| OVD usage | No | Yes |
| OVD removal | No | Yes |
| Unfolding of the PIOL | Quick | Slow |
| Consumption of BSS | Less | More |
| Duration of surgery | Short | Long |
OVD = Ophthalmic Viscosurgical Device
Preoperative patient demographics in eyes undergoing either method of phakic intraocular Lens (PIOL) implantation
| Demographic | OVD-free method | Standard method | |
|---|---|---|---|
| Age (SD), year | 28.50 (3.97) | 26.81 (6.04) | 0.243 |
| Sex (%, female) | 50.0% | 85.7% | 0.009 |
| SE (SD), D | −13.09 (3.26) | − 13.49 (3.27) | 0.676 |
| AL (SD), mm | 28.53 (1.62) | 28.15 (1.73) | 0.439 |
| UDVA (IQR), logMAR | 1.22 (1.02–1.40) | 1.30 (1.16–1.40) | 0.342 |
| CDVA (IQR), logMAR | 0.10 (0–0.15) | 0.15 (0.05–0.30) | 0.103 |
| ACD (IQR), mm | 3.59 (3.46–3.81) | 3.73 (3.64–3.78) | 0.084 |
| CCT (IQR), μm | 538.5 (518.0–564.8) | 523.0 (492.5–560.0) | 0.196 |
| ECD (IQR), cells/mm2 | 2620.6 (2431.9–2983.9) | 2620.6 (2490.7–2963.0) | 0.664 |
| IOP (IQR), mmHg | 14.45 (12.65–15.95) | 15.10(13.80–17.40) | 0.122 |
| PIOL Power (SD), D | −13.88 (2.78) | −14.93(2.18) | 0.158 |
OVD = Ophthalmic Viscosurgical Device; SE = Spherical equivalent; AL = Axial length; UDVA = Uncorrected distance visual acuity; CDVA = Corrected distance visual acuity; ACD = Anterior chamber depth; CCT = Center corneal thickness; ECD = Endothelial cell density; IOP = Intraocular pressure; SD = Standard deviation; IQR = Interquartile range
Fig. 2Time course of intraocular pressure changes in eyes undergoing the standard method of phakic intraocular lens (PIOL) implantation and Ophthalmic Viscosurgical Device-free method of PIOL implantation. Error bars represent standard error of mean
Fig. 3The difference of intraocular pressure between baseline (preoperation) and each time point in eyes undergoing the standard method of phakic intraocular lens (PIOL) implantation and Ophthalmic Viscosurgical Device-free method of PIOL implantation. Error bars represent standard error of mean. The asterisk represents statistically significant differences between the two groups (8.3, 95% CI 5.8 to 10.8; p < 0.001)
Fig. 4Time course of spherical equivalent changes in eyes undergoing the standard method of phakic intraocular lens (PIOL) implantation and Ophthalmic Viscosurgical Device-free method of PIOL implantation
Management of early acute intraocular pressure elevation in 14 eyes following the standard method of phakic intraocular lens (PIOL) implantation
| Management | Number of eyes |
|---|---|
| Without treatment, No. (%) | 3 (21) |
| AC drainage only, No. (%) | 6 (43) |
| TAM combined with AC drainage, No. (%) | 5 (36) |
TAM = Topical antiglaucoma medications; AC = Anterior chamber