Literature DB >> 25033901

Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study.

S Khokhar1, R Sharma1, B Patil1, N Aron1, S Gupta1.   

Abstract

PURPOSE: To compare intraocular lens implantation using a motorized injector vs standard manual injector through a 2.2-mm clear corneal incision.
METHODS: Patients underwent standard phacoemulsification using a 2.2-mm clear corneal incision. Hydrophobic acrylic aspheric intraocular lens (Acrysof SN60WF intraocular lens (IOL)) was inserted using D cartridge with manual monarch injector or autosert motorized injector. IOL safety, final incision size and wound integrity in terms of anterior and posterior wound gape, and descemet's membrane detachment were compared between the two groups at post-operative day 1 and at 1 month using Anterior Segment Optical Coherence Tomography.
RESULTS: The study recruited 32 patients in the group I (manual injector) and 30 patients in group II (motorized injector). In group I, the final incision after IOL insertion increased by 0.12 mm (95% CI: 0.134-0.106) (P<0.0001), which was seen in 100% of the patients. In group II, the incision enlarged by 0.01 (95% CI: 0.021-0.0.001) (P=0.07) and was seen in only 6.67% of the cases. IOL nicks were seen in 9.37% of the cases in group I only. Although the incidence of descemet's membrane detachment and anterior wound gape was similar for both groups, posterior wound gape was seen more often with the manual injector in the immediate post-operative period. (P=0.018)
CONCLUSION: The motorized insertion system was gentle and safe for the IOLs with lesser incidence of IOL nicks. Regarding wound safety, it caused significantly less incision enlargement and better posterior wound integrity.

Entities:  

Mesh:

Year:  2014        PMID: 25033901      PMCID: PMC4194333          DOI: 10.1038/eye.2014.162

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  24 in total

1.  Final incision size after implantation of a hydrophobic acrylic aspheric intraocular lens: new motorized injector versus standard manual injector.

Authors:  David Allen; Maged Habib; David Steel
Journal:  J Cataract Refract Surg       Date:  2011-12-09       Impact factor: 3.351

2.  Healing changes in clear corneal cataract incisions evaluated using Fourier-domain optical coherence tomography.

Authors:  Li Wang; Lena Dixit; Mitchell P Weikert; Richard B Jenkins; Douglas D Koch
Journal:  J Cataract Refract Surg       Date:  2012-02-10       Impact factor: 3.351

3.  Microcoaxial phacoemulsification Part 2: clinical study.

Authors:  Robert H Osher
Journal:  J Cataract Refract Surg       Date:  2007-03       Impact factor: 3.351

4.  In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography.

Authors:  Sylvère Dupont-Monod; Antoine Labbé; Nicolas Fayol; Alexis Chassignol; Jean-Louis Bourges; Christophe Baudouin
Journal:  J Cataract Refract Surg       Date:  2009-03       Impact factor: 3.351

5.  Incision sizes before and after implantation of SN60WF intraocular lenses using the Monarch injector system with C and D cartridges.

Authors:  Thomas Kohnen; Oliver K Klaproth
Journal:  J Cataract Refract Surg       Date:  2008-10       Impact factor: 3.351

6.  Incision sizes at different stages of phacoemulsification with foldable intraocular lens implantation.

Authors:  Cesar Ramon G Espiritu; Juanchito P Bernardo
Journal:  J Cataract Refract Surg       Date:  2009-12       Impact factor: 3.351

7.  Anterior segment optical coherence tomography evaluation of the integrity of clear corneal incisions: a comparison between 2.2-mm and 2.65-mm main incisions.

Authors:  Soon-Phaik Chee; Seng-Ei Ti; Li Lim; Anita S Y Chan; Aliza Jap
Journal:  Am J Ophthalmol       Date:  2010-02-26       Impact factor: 5.258

8.  OCT-documented incision features and natural history of clear corneal incisions used for bimanual microincision cataract surgery.

Authors:  Graham W Lyles; Kenneth L Cohen; Diana Lam
Journal:  Cornea       Date:  2011-06       Impact factor: 2.651

9.  Induced astigmatism with 2.2- and 3.0-mm coaxial phacoemulsification incisions.

Authors:  Samuel Masket; Li Wang; Shaleen Belani
Journal:  J Refract Surg       Date:  2009-01       Impact factor: 3.573

10.  Corneal incision quality: microincision cataract surgery versus microcoaxial phacoemulsification.

Authors:  Bassam Elkady; David Piñero; Jorge L Alió
Journal:  J Cataract Refract Surg       Date:  2009-03       Impact factor: 3.351

View more
  8 in total

1.  A different approach for manual foldable IOL injection for keeping wound size and integrity.

Authors:  E Özyol; P Özyol
Journal:  Eye (Lond)       Date:  2014-12-19       Impact factor: 3.775

2.  In vivo and in vitro results of an automated preloaded delivery system for IOL implantation in cataract surgery.

Authors:  Leonardo Mastropasqua; Lisa Toto; Erminia D'Ugo; Manuela Lanzini; Peter A Mattei; Gennaro Falconio; Emanuele Doronzo; Francesca Diomede; Oriana Trubiani
Journal:  Int Ophthalmol       Date:  2019-08-26       Impact factor: 2.031

3.  Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector with/without Pause Time and a Manual Injector.

Authors:  Hisanori Imai; Ayaka Fujii; Emiko Tani; Atsushi Azumi
Journal:  J Ophthalmol       Date:  2016-02-17       Impact factor: 1.909

4.  Comparison of incision size and intraocular lens performance after implantation with three preloaded systems and one manual delivery system.

Authors:  Javier Mendicute; Thierry Amzallag; Lixin Wang; Aldo A Martinez
Journal:  Clin Ophthalmol       Date:  2018-08-21

5.  Clinical Evaluation of a Novel Preloaded Intraocular Lens Delivery System During Routine Cataract Surgery.

Authors:  Daniel Black; Dean Corbett; Timothy V Roberts; Brendan Cronin; Pamela J Smith; D Priya Janakiraman; Beth E Jackson
Journal:  Clin Ophthalmol       Date:  2020-08-12

6.  Experimental Study on Delivery Performance of an Automated Preloaded Intraocular Lens Injector System for Corneal and Sclerocorneal Incisions.

Authors:  Tetsuro Oshika; Noriyuki Sasaki
Journal:  J Ophthalmol       Date:  2021-03-31       Impact factor: 1.909

7.  Comparison of two techniques for toric intraocular lens implantation: hydroimplantation versus ophthalmic viscosurgical devices.

Authors:  Yueqin Chen; Qian Cao; Chunyan Xue; Zhenping Huang
Journal:  BMC Ophthalmol       Date:  2018-04-24       Impact factor: 2.209

8.  Multicenter Evaluation of Time, Operational, and Economic Efficiencies of a New Preloaded Intraocular Lens Delivery System versus Manual Intraocular Lens Delivery.

Authors:  Javier Mendicute; Lucia Bascarán; Luis Pablo; Cédric Schweitzer; Laurent Velasque; Christine Bouchet; Aldo A Martinez
Journal:  Clin Ophthalmol       Date:  2021-02-16
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.