Literature DB >> 29556317

Tumor bed radiotherapy in women following breast conserving surgery for breast cancer-safety margin with/without image guidance.

Ales Hlavka1,2, Jaroslav Vanasek1,2,3, Karel Odrazka1,4,5,6, Jan Stuk1,2, Martin Dolezel1,4,7, Vit Ulrych1, Martina Vitkova1, Jiri Mynarik1, Iveta Kolarova1,2,3, Zdenka Vilasova1,3.   

Abstract

Image guided radiation therapy (IGRT) enables the achievement of higher precision in radiation delivery, a reduction in safety margins and a reduced risk of toxicity in healthy tissues. The present study investigated the magnitude of safety margins for the radiation boost setup on skin marks or metal clips implanted into the tumor bed during breast cancer surgery. One hundred eighty-four patients after breast conserving surgery with implanted metal clips into tumor bed were analyzed. The present study investigated the difference in safety margin required for the treatment setup on skin marks and metal clips. The skin marks were created using a positioning laser system in the treatment room. Metal clips implanted in the tumor bed were registered using IGRT with kilovoltage X-rays in orthogonal projection. Treatment setup was performed during free breathing. The safety margin corresponding to the planning target volume (PTV) was calculated from the recorded data. Calculated safety margins for the treatment setup on skin marks were 9.4, 11.1 and 11.1 mm in the anteroposterior, craniocaudal, and laterolateral directions, respectively. Corresponding safety margins with the use of IGRT and metal clips registration were 4.7, 5.1 and 5.9 mm, respectively. The safe PTV margin was 12 mm using setup on skin marks without IGRT, whereas a 6-mm margin was sufficient with the use of metal clip-based IGRT with daily online correction. IGRT has been adopted as the standard treatment method within the Oncology Centre of Multiscan and Pardubice Hospital (Pardubice, Czech Republic).

Entities:  

Keywords:  breast cancer; fiducials; image-guided; radiotherapy

Year:  2018        PMID: 29556317      PMCID: PMC5844069          DOI: 10.3892/ol.2018.8083

Source DB:  PubMed          Journal:  Oncol Lett        ISSN: 1792-1074            Impact factor:   2.967


  15 in total

1.  The validity of surgical clips as a radiographic surrogate for the lumpectomy cavity in image-guided accelerated partial breast irradiation.

Authors:  Daniel W Weed; Di Yan; Alvaro A Martinez; Frank A Vicini; T J Wilkinson; John Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-10-01       Impact factor: 7.038

2.  Validating fiducial markers for image-guided radiation therapy for accelerated partial breast irradiation in early-stage breast cancer.

Authors:  Catherine K Park; Jakub Pritz; Geoffrey G Zhang; Kenneth M Forster; Eleanor E R Harris
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-03-01       Impact factor: 7.038

3.  Intrafractional target motions and uncertainties of treatment setup reference systems in accelerated partial breast irradiation.

Authors:  Ning J Yue; Sharad Goyal; Jinghao Zhou; Atif J Khan; Bruce G Haffty
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-08-26       Impact factor: 7.038

4.  Improvement in interobserver accuracy in delineation of the lumpectomy cavity using fiducial markers.

Authors:  Talha Shaikh; Ting Chen; Atif Khan; Ning J Yue; Thomas Kearney; Alan Cohler; Bruce G Haffty; Sharad Goyal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-19       Impact factor: 7.038

5.  Image-guided radiotherapy for breast cancer patients: surgical clips as surrogate for breast excision cavity.

Authors:  Rajko Topolnjak; Peter de Ruiter; Peter Remeijer; Corine van Vliet-Vroegindeweij; Coen Rasch; Jan-Jakob Sonke
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-02-23       Impact factor: 7.038

6.  Searching for an appropriate image-guided radiotherapy method in prostate cancer--implications for safety margin.

Authors:  Jaroslav Vanasek; Karel Odrazka; Martin Dolezel; Ladislav Dusek; Jiri Jarkovsky; Ales Hlavka; Eva Valentova; Iveta Kolarova
Journal:  Tumori       Date:  2014 Sep-Oct       Impact factor: 2.098

7.  Effect of breathing motion in radiotherapy of breast cancer: 4D dose calculation and motion tracking via EPID.

Authors:  Anne Richter; Reinhard Sweeney; Kurt Baier; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2009-08-28       Impact factor: 3.621

8.  Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer.

Authors:  Bernard Fisher; Stewart Anderson; John Bryant; Richard G Margolese; Melvin Deutsch; Edwin R Fisher; Jong-Hyeon Jeong; Norman Wolmark
Journal:  N Engl J Med       Date:  2002-10-17       Impact factor: 91.245

Review 9.  Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10,801 women in 17 randomised trials.

Authors:  S Darby; P McGale; C Correa; C Taylor; R Arriagada; M Clarke; D Cutter; C Davies; M Ewertz; J Godwin; R Gray; L Pierce; T Whelan; Y Wang; R Peto
Journal:  Lancet       Date:  2011-10-19       Impact factor: 79.321

10.  Correlation between target motion and the dosimetric variance of breast and organ at risk during whole breast radiotherapy using 4DCT.

Authors:  Wei Wang; Jian Bin Li; Hong Guang Hu; Feng Xiang Li; Min Xu; Tao Sun; Jie Lu
Journal:  Radiat Oncol       Date:  2013-05-02       Impact factor: 3.481

View more
  4 in total

1.  Ultrasound-assisted carbon ion dosimetry and range measurement using injectable polymer-shelled phase-change nanodroplets: in vitro study.

Authors:  Yosra Toumia; Marco Pullia; Fabio Domenici; Angelica Facoetti; Michele Ferrarini; Sophie V Heymans; Bram Carlier; Koen Van Den Abeele; Edmond Sterpin; Jan D'hooge; Emiliano D'Agostino; Gaio Paradossi
Journal:  Sci Rep       Date:  2022-05-14       Impact factor: 4.996

Review 2.  Target motion management in breast cancer radiation therapy.

Authors:  Elham Piruzan; Naser Vosoughi; Seied Rabi Mahdavi; Leila Khalafi; Hojjat Mahani
Journal:  Radiol Oncol       Date:  2021-10-08       Impact factor: 2.991

3.  A novel, adaptable, radiographically opaque, multi-plane continuous filament marker for optimizing tissue identification, radiation planning, and radiographic follow-up.

Authors:  Sunny Mitchell; Henry Lee; Beth Baughman DuPree; David C Beyer; Michael Ulissey; Stephen R Grobmyer; Jennifer Gass; Susan Boolbol; Toni Storm-Dickerson
Journal:  Gland Surg       Date:  2019-12

Review 4.  Adaptive radiation therapy of breast cancer by repeated imaging during irradiation.

Authors:  Omer Sager; Ferrat Dincoglan; Selcuk Demiral; Bora Uysal; Hakan Gamsiz; Fatih Ozcan; Onurhan Colak; Yelda Elcim; Esin Gundem; Bahar Dirican; Murat Beyzadeoglu
Journal:  World J Radiol       Date:  2020-05-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.