Literature DB >> 15380583

The validity of surgical clips as a radiographic surrogate for the lumpectomy cavity in image-guided accelerated partial breast irradiation.

Daniel W Weed1, Di Yan, Alvaro A Martinez, Frank A Vicini, T J Wilkinson, John Wong.   

Abstract

PURPOSE: We hypothesize that surgical clips placed in the biopsy cavity during lumpectomy can be used as radiographic markers to facilitate image-guided external beam accelerated partial breast irradiation. METHODS AND MATERIALS: We evaluated 28 patients with surgically placed clips in the lumpectomy cavity and two CT scans on different days. To establish whether the clips remain predictive of the lumpectomy cavity throughout therapy, we analyzed the motion of both cavities with repeat volumetric CT scans. The three-dimensional (3D) locations of each lumpectomy cavity and the associated clips were defined as individual regions of interest (ROIs). A single point of interest (POI) was defined for each ROI. The calculated movements of the lumpectomy cavity POIs between different scans were compared to those of the clip POIs. The second CT data set was then moved in accordance to the calculated clip POI's movement. The volume of the (second) lumpectomy cavity associated with the second scan outside of the (first) cavity of the first scan was measured. In addition, the required amount of a radial margin expansion around the first lumpectomy cavity to ensure coverage of the second lumpectomy cavity both before and after moving the second lumpectomy according to the clip POI movement was calculated.
RESULTS: The two CT scans were obtained on average 27 days apart, and the mean lumpectomy size decreased from 35 to 16 cc. The clip and lumpectomy cavity POIs moved a mean of 3 mm along the three principal Cartesian axes. In moving the second lumpectomy cavity according to the clip POI displacement from its original position, the volume of the second lumpectomy cavity outside of the volume of the first decreased from 2.6 cc to 1.0 cc after correction, and the required radial margin on the first lumpectomy cavity to include the second lumpectomy cavity decreased from 5.5 mm vs. 3.8 mm.
CONCLUSION: The surgically placed clips after lumpectomy are strong radiographic surrogates for the biopsy cavity. If the clips were used to guide accelerated partial breast irradiation, a planning target volume margin of the order of 5 mm could be used, significantly smaller than the 10-mm margin currently employed.

Entities:  

Mesh:

Year:  2004        PMID: 15380583     DOI: 10.1016/j.ijrobp.2004.03.012

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  22 in total

1.  3-D conformal photon boost in the treatment of early stage breast cancer: four year follow up results.

Authors:  Arpad Kovacs; Ferenc Lakosi; Gabor Liposits; Gabor Toller; Janaki Hadjiev; Csaba Vandulek; Norbert Walter; Csaba Glavak; Gergely Antal; Akos Horvath; Imre Repa; Peter Bogner
Journal:  Pathol Oncol Res       Date:  2010-04-11       Impact factor: 3.201

2.  Comparison of set-up errors by breast size on wing board by portal imaging.

Authors:  Waseem Raza; Sushma Agarwal; Koilpillai Joseph Maria Das; Sellepolyam Kaliyaperumal Senthil Kumar; Punita Lal
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-06

3.  Tumor bed radiotherapy in women following breast conserving surgery for breast cancer-safety margin with/without image guidance.

Authors:  Ales Hlavka; Jaroslav Vanasek; Karel Odrazka; Jan Stuk; Martin Dolezel; Vit Ulrych; Martina Vitkova; Jiri Mynarik; Iveta Kolarova; Zdenka Vilasova
Journal:  Oncol Lett       Date:  2018-02-16       Impact factor: 2.967

4.  Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation.

Authors:  Gang Cai; Wei-Gang Hu; Jia-Yi Chen; Xiao-Li Yu; Zi-Qiang Pan; Zhao-Zhi Yang; Xiao-Mao Guo; Zhi-Min Shao; Guo-Liang Jiang
Journal:  Radiat Oncol       Date:  2010-10-26       Impact factor: 3.481

Review 5.  Accelerated Partial Breast Irradiation (APBI): A review of available techniques.

Authors:  Christopher F Njeh; Mark W Saunders; Christian M Langton
Journal:  Radiat Oncol       Date:  2010-10-04       Impact factor: 3.481

6.  Unacceptable cosmesis in a protocol investigating intensity-modulated radiotherapy with active breathing control for accelerated partial-breast irradiation.

Authors:  Reshma Jagsi; Merav A Ben-David; Jean M Moran; Robin B Marsh; Kent A Griffith; James A Hayman; Lori J Pierce
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-01-01       Impact factor: 7.038

7.  Variability of target and normal structure delineation for breast cancer radiotherapy: an RTOG Multi-Institutional and Multiobserver Study.

Authors:  X Allen Li; An Tai; Douglas W Arthur; Thomas A Buchholz; Shannon Macdonald; Lawrence B Marks; Jean M Moran; Lori J Pierce; Rachel Rabinovitch; Alphonse Taghian; Frank Vicini; Wendy Woodward; Julia R White
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-01       Impact factor: 7.038

8.  Image guidance using 3D-ultrasound (3D-US) for daily positioning of lumpectomy cavity for boost irradiation.

Authors:  Manjeet Chadha; Amy Young; Charles Geraghty; Robert Masino; Louis Harrison
Journal:  Radiat Oncol       Date:  2011-05-09       Impact factor: 3.481

9.  Optimization of Adjuvant Radiation in Breast Conservation Therapy: Can We Minimize without Compromise?

Authors:  Sophia M Edwards-Bennett; Candace R Correa; Eleanor E Harris
Journal:  Int J Breast Cancer       Date:  2011-10-05

10.  Volumetric changes in the lumpectomy cavity during whole breast irradiation after breast conserving surgery.

Authors:  Heunglae Cho; Cheoljin Kim
Journal:  Radiat Oncol J       Date:  2011-12-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.