Literature DB >> 22284037

Validating fiducial markers for image-guided radiation therapy for accelerated partial breast irradiation in early-stage breast cancer.

Catherine K Park1, Jakub Pritz, Geoffrey G Zhang, Kenneth M Forster, Eleanor E R Harris.   

Abstract

PURPOSE: Image-guided radiation therapy (IGRT) may be beneficial for accelerated partial breast irradiation (APBI). The goal was to validate the use of intraparenchymal textured gold fiducials in patients receiving APBI. METHODS AND MATERIALS: Twenty-six patients were enrolled on this prospective study that had three or four textured gold intraparenchymal fiducials placed at the periphery of the lumpectomy cavity and were treated with three-dimensional (3D) conformal APBI. Free-breathing four-dimensional computed tomography image sets were obtained pre- and posttreatment, as were daily online megavoltage (MV) orthogonal images. Intrafraction motion, variations in respiratory motion, and fiducial marker migration were calculated using the 3D coordinates of individual fiducials and a calculated center of mass (COM) of the fiducials. We also compared the relative position of the fiducial COM with the geometric center of the seroma.
RESULTS: There was less than 1 mm of intrafraction respiratory motion, variation in respiratory motion, or fiducial marker migration. The change in seroma position relative to the fiducial COM was 1 mm ± 1 mm. The average position of the geometric seroma relative to the fiducial COM pretreatment compared with posttreatment was 1 mm ± 1 mm. The largest daily variation in displacement when using bony landmark was in the anteroposterior direction and two standard deviations (SD) of this variation was 10 mm. The average variation in daily separation between the fiducial pairs from daily MV images was 3 mm ± 3 mm therefore 2 SD is 6 mm.
CONCLUSION: Fiducial markers are stable throughout the course of APBI. Planning target volume margins when using bony landmarks should be 10 mm and can be reduced to 6 mm if using fiducials.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22284037     DOI: 10.1016/j.ijrobp.2011.07.027

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  12 in total

1.  Displacement of the lumpectomy cavity defined by surgical clips and seroma based on 4D-CT scan for external-beam partial breast irradiation after breast-conserving surgery: a comparative study.

Authors:  Y Ding; J Li; W Wang; S Wang; T Fan; M Xu; Q Shao; Z Ma
Journal:  Br J Radiol       Date:  2013-08-30       Impact factor: 3.039

2.  Air-electron stream interactions during magnetic resonance IGRT : Skin irradiation outside the treatment field during accelerated partial breast irradiation.

Authors:  Jong Min Park; Kyung Hwan Shin; Jung-In Kim; So-Yeon Park; Seung Hyuck Jeon; Noorie Choi; Jin Ho Kim; Hong-Gyun Wu
Journal:  Strahlenther Onkol       Date:  2017-09-15       Impact factor: 3.621

3.  Residual image registration error by fiducial markers in accelerated partial breast irradiation using C-arm linac: a phantom study.

Authors:  Ryohei Yamauchi; Natsuki Murayoshi; Shinobu Akiyama; Norifumi Mizuno; Tomoyuki Masuda; Tomoko Itazawa; Jiro Kawamori
Journal:  Phys Eng Sci Med       Date:  2022-06-03

4.  Tumor bed radiotherapy in women following breast conserving surgery for breast cancer-safety margin with/without image guidance.

Authors:  Ales Hlavka; Jaroslav Vanasek; Karel Odrazka; Jan Stuk; Martin Dolezel; Vit Ulrych; Martina Vitkova; Jiri Mynarik; Iveta Kolarova; Zdenka Vilasova
Journal:  Oncol Lett       Date:  2018-02-16       Impact factor: 2.967

5.  A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy.

Authors:  Peng-Yi Lee; Chih-Yuan Lin; Shang-Wen Chen; Chun-Ru Chien; Chun-Nan Chu; Hsiu-Ting Hsu; Ji-An Liang; Ying-Jun Lin; An-Cheng Shiau
Journal:  Radiat Oncol       Date:  2017-03-20       Impact factor: 3.481

6.  MRI Reduces Variation of Contouring for Boost Clinical Target Volume in Breast Cancer Patients Without Surgical Clips in the Tumour Bed.

Authors:  Noora Al-Hammadi; Palmira Caparrotti; Saju Divakar; Mohamed Riyas; Suparna Halsnad Chandramouli; Rabih Hammoud; Jillian Hayes; Maeve Mc Garry; Satheesh Prasad Paloor; Primoz Petric
Journal:  Radiol Oncol       Date:  2017-03-17       Impact factor: 2.991

7.  A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery.

Authors:  Yun Ding; Jianbin Li; Wei Wang; Suzhen Wang; Jinzhi Wang; Zhifang Ma; Qian Shao; Min Xu
Journal:  Radiat Oncol       Date:  2014-03-19       Impact factor: 3.481

8.  Target volume delineation in breast conserving radiotherapy: are co-registered CT and MR images of added value?

Authors:  Mirjam Mast; Emile Coerkamp; Mark Heijenbrok; Astrid Scholten; Wim Jansen; Erik Kouwenhoven; Jasper Nijkamp; Stephanie de Waard; Anna Petoukhova; Henk Struikmans
Journal:  Radiat Oncol       Date:  2014-02-26       Impact factor: 3.481

9.  Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation.

Authors:  Xin Zhen; Bo Zhao; Zhuoyu Wang; Robert Timmerman; Ann Spangler; Nathan Kim; Asal Rahimi; Xuejun Gu
Journal:  Radiat Oncol       Date:  2017-09-11       Impact factor: 3.481

10.  Surface imaging-based analysis of intrafraction motion for breast radiotherapy patients.

Authors:  David B Wiant; Stacy Wentworth; Jacqueline M Maurer; Caroline L Vanderstraeten; Jonathon A Terrell; Benjamin J Sintay
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.