Literature DB >> 20304565

Improvement in interobserver accuracy in delineation of the lumpectomy cavity using fiducial markers.

Talha Shaikh1, Ting Chen, Atif Khan, Ning J Yue, Thomas Kearney, Alan Cohler, Bruce G Haffty, Sharad Goyal.   

Abstract

PURPOSE: To determine, whether the presence of gold fiducial markers would improve the inter- and intraphysician accuracy in the delineation of the surgical cavity compared with a matched group of patients who did not receive gold fiducial markers in the setting of accelerated partial-breast irradiation (APBI). METHODS AND MATERIALS: Planning CT images of 22 lumpectomy cavities were reviewed in a cohort of 22 patients; 11 patients received four to six gold fiducial markers placed at the time of surgery. Three physicians categorized the seroma cavity according to cavity visualization score criteria and delineated each of the 22 seroma cavities and the clinical target volume. Distance between centers of mass, percentage overlap, and average surface distance for all patients were assessed.
RESULTS: The mean seroma volume was 36.9 cm(3) and 34.2 cm(3) for fiducial patients and non-fiducial patients, respectively (p = ns). Fiducial markers improved the mean cavity visualization score, to 3.6 ± 1.0 from 2.5 ± 1.3 (p < 0.05). The mean distance between centers of mass, average surface distance, and percentage overlap for the seroma and clinical target volume were significantly improved in the fiducial marker patients as compared with the non-fiducial marker patients (p < 0.001).
CONCLUSIONS: The placement of gold fiducial markers placed at the time of lumpectomy improves interphysician identification and delineation of the seroma cavity and clinical target volume. This has implications in radiotherapy treatment planning for accelerated partial-breast irradiation and for boost after whole-breast irradiation.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20304565     DOI: 10.1016/j.ijrobp.2009.09.025

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  11 in total

1.  Consensus statement on tumour bed localization for radiation after oncoplastic breast surgery.

Authors:  T Tse; S Knowles; J Bélec; J M Caudrelier; M Lock; M Brackstone; A Arnaout
Journal:  Curr Oncol       Date:  2020-06-01       Impact factor: 3.677

2.  Impact of a Novel Bioabsorbable Implant on Radiation Treatment Planning for Breast Cancer.

Authors:  Michael J Cross; Gail S Lebovic; Joseph Ross; Scott Jones; Arnold Smith; Steven Harms
Journal:  World J Surg       Date:  2017-02       Impact factor: 3.352

3.  Tumor bed radiotherapy in women following breast conserving surgery for breast cancer-safety margin with/without image guidance.

Authors:  Ales Hlavka; Jaroslav Vanasek; Karel Odrazka; Jan Stuk; Martin Dolezel; Vit Ulrych; Martina Vitkova; Jiri Mynarik; Iveta Kolarova; Zdenka Vilasova
Journal:  Oncol Lett       Date:  2018-02-16       Impact factor: 2.967

4.  Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation.

Authors:  Bing Guo; Jianbin Li; Wei Wang; Min Xu; Qian Shao; Yingjie Zhang; Chaoqian Liang; Yanluan Guo
Journal:  Radiat Oncol       Date:  2015-03-13       Impact factor: 3.481

5.  MRI Reduces Variation of Contouring for Boost Clinical Target Volume in Breast Cancer Patients Without Surgical Clips in the Tumour Bed.

Authors:  Noora Al-Hammadi; Palmira Caparrotti; Saju Divakar; Mohamed Riyas; Suparna Halsnad Chandramouli; Rabih Hammoud; Jillian Hayes; Maeve Mc Garry; Satheesh Prasad Paloor; Primoz Petric
Journal:  Radiol Oncol       Date:  2017-03-17       Impact factor: 2.991

Review 6.  Accelerated Partial Breast Irradiation (APBI): Where Are We Now?

Authors:  Mira Goldberg; Timothy J Whelan
Journal:  Curr Breast Cancer Rep       Date:  2020-10-18

7.  Inter-observer variations of the tumor bed delineation for patients after breast conserving surgery in preoperative magnetic resonance and computed tomography scan fusion.

Authors:  Jie Jiang; Jinhu Chen; Wanhu Li; Yongqing Li; Yiru Chen; Zicheng Zhang; Chengxin Liu; Dan Han; Hongfu Sun; Baosheng Li; Wei Huang
Journal:  BMC Cancer       Date:  2021-07-20       Impact factor: 4.430

8.  A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery.

Authors:  Yun Ding; Jianbin Li; Wei Wang; Suzhen Wang; Jinzhi Wang; Zhifang Ma; Qian Shao; Min Xu
Journal:  Radiat Oncol       Date:  2014-03-19       Impact factor: 3.481

9.  Cone-beam computed tomography image guided therapy to evaluate lumpectomy cavity variation before and during breast radiotherapy.

Authors:  Minh Tam Truong; Ariel E Hirsch; Nataliya Kovalchuk; Muhammad M Qureshi; Antonio Damato; Bradley Schuller; Nectaria Vassilakis; Michael Stone; David Gierga; John Willins; Lisa A Kachnic
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

10.  Analysis of the variability among radiation oncologists in delineation of the postsurgical tumor bed based on 4D-CT.

Authors:  Wei Wang; Jianbin Li; Jun Xing; Min Xu; Qian Shao; Tingyong Fan; Bing Guo; Shanshan Liu
Journal:  Oncotarget       Date:  2016-10-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.