| Literature DB >> 29541265 |
Victor Feliz Pedrinha1, Juliana Melo da Silva Brandão1, Oscar Faciola Pessoa1, Patrícia de Almeida Rodrigues1.
Abstract
Advances in endodontics have enabled the evolution of file manufacturing processes, improving performance beyond that of conventional files. In the present study, systems manufactured using state of the art methods and possessing special properties related to NiTi alloys (i.e., CM-Wire, M-Wire and R-Phase) were selected. The aim of this review was to provide a detailed analysis of the literature about the relationship between recently introduced NiTi files with different movement kinematics and shaping ability, apical extrusion of debris and dentin defects in root canal preparations. From March 2016 to January 2017, electronic searches were conducted in the PubMed and SCOPUS databases for articles published since January 2010. In vitro studies performed on extracted human teeth and published in English were considered for this review. Based on the inclusion criteria, 71 papers were selected for the analysis of full-text copies. Specific analysis was performed on 45 articles describing the effects of reciprocating, continuous and adaptive movements on the WaveOne Gold, Reciproc, HyFlex CM and Twisted File Adaptive systems. A wide range of testing conditions and methodologies have been used to compare the systems. Due the controversies among the results, the characteristics of the files used, such as their design and alloys, appear to be inconsistent to determine the best approach.Entities:
Keywords: Endodontic files; Endodontically treated teeth; Kinematics; Nickel-titanium; Root canal preparation; Root canal therapy
Year: 2018 PMID: 29541265 PMCID: PMC5842382 DOI: 10.2174/1874210601812010189
Source DB: PubMed Journal: Open Dent J ISSN: 1874-2106
Summary of characteristics of the studies about shaping ability.
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|
| Mn molar | 64 | Reciproc | R | µCT | Reciproc and WaveOne > Twisted File and HyFlex CM | |
| Mn molar | 60 | Oneshape | CR | Radiographic | Oneshape > Reciproc and WaveOne | |
| Mn molar | 45 | HyFlex CM | CR | CBCT | ProTaper > WaveOne > HyFlex | |
| Mn molar | 120 | Oneshape | CR | CBCT | Oneshape > WaveOne and Reciproc | |
| Human teeth (type not mentioned) | 80 | Mtwo | CR | Radiographic | No significant difference | |
| Mx molar | 45 | Mtwo | CR and R | µCT | Mtwo RC > Mtwo R and WaveOne | |
| Human teeth (type not mentioned) | 80 | Mtwo | CR | Radiographic | No significant difference | |
| Mn molar | 64 | K-File | MI | CBCT | Mtwo > Reciproc | |
| Mx molar | 60 | Reciproc | R | Radiographic | Reciproc > BioRace | |
| Mx molar | 60 | ProTaper | CR | CBCT | No significant difference | |
| Mn molar | 45 | Neoniti | CR | CBCT | Reciproc > Neoniti | |
| Mx molar | 90 | Self-Adjusting File | CR | µCT | Reciproc > Self-Adjusting File and Revo-S | |
| Mn molar | 48 | Reciproc | R | µCT | Reciproc and WaveOne > Twisted File Adaptive | |
| Mn molar | 64 | Mtwo | CR and AM | µCT | No significant difference | |
| Mn molar | 48 | Reciproc | R | µCT | Reciproc and WaveOne > Twisted File Adaptive | |
| Mn molar | 120 | Oneshape | CR | CBCT | No significant difference |
Mn, mandible; Mx, maxillar, VC, vestibular canal; PC, palatine canal; MI, manual instrumentation; AM, adaptive movement; CR, continuous rotation; R, reciprocation; CT, computed tomography; CBCT, cone beam computed tomography.
Summary of characteristics of the studies about apical debris.
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|
| Mn premolar | 80 | ProTaper Gold | CR | Distilled water | ProTaper Universal > WaveOne, ProTaper Gold and WaveOne Gold | |
| Mn incisor | 80 | Reciproc | R | Distilled water | Reciproc > F360, OneShape and Mtwo | |
| Mn premolar | 45 | Reciproc | R | Distilled water | No significant difference | |
| Mn premolar | 60 | Reciproc | R | NaOCl | Reciproc > WaveOne > HyFlex CM | |
| Mn premolar | 60 | ProTaper | CR | Distilled water | WaveOne and ProTaper > HyFlex CM | |
| Mn premolar | 60 | ProTaper Universal | CR | Distilled water | ProTaper Universal and HyFlex CM > ProTaper Next and Twisted File Adaptive | |
| Mn incisor | 48 | ProTaper Next | CR | Distilled water | No significant difference | |
| Mn incisor | 72 | Twisted File Adaptive | R | Distilled water | R > CR | |
| Mn incisor | 80 | Reciproc | R | Distilled water | WaveOne and Reciproc > Mtwo and ProTaper | |
| Mx incisor | 45 | Reciproc | R | Distilled water | CR > R | |
| Mn molar | 48 | ProTaper | CR | Distilled water | ProTaper > WaveOne and Reciproc | |
| Mn molar | 80 | ProTaper Gold | CR | Distilled water | ProTaper Universal and HyFlex CM > ProTaper Gold and Reciproc | |
| Mn premolar | 60 | WaveOne | R | Distilled water | Mtwo, ProTaper Universal, Typhoon, SafeSider and WaveOne > Reciproc | |
| Anterior teeth (type not mentioned) | 80 | Reciproc | R | Saline solution | BLX and ProTaper > Reciproc and WaveOne | |
| Mn premolar | 60 | Reciproc | R | Distilled water | Reciproc and Waveone > Oneshape | |
| Mn premolar | 60 | ProTaper Universal | CR | Distilled water | ProTaper Universal > ProTaper Next, WaveOne and Reciproc | |
| Mn premolar | 60 | Vortex Blue | CR | Distilled water | K3XF and Reciproc > Vortex Blue and ProTaper Next | |
| Mn premolar | 90 | Reciproc | R | Distilled water | No significant difference |
Mn, mandible; Mx, maxillar; MA, adaptive movement; RC, continuous rotation; R, reciprocation.
Summary of characteristics of the studies about dentinal defects.
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|
| Mn molar | 160 | ProFile | CR | Led transillumination | No significance difference | |
| Mn incisor | 120 | K-File | MI | SEM | No significance difference | |
| Mn molar | 180 | Reciproc | R | SEM | Reciproc > WaveOne and Twisted File Adaptive | |
| Mn premolar | 100 | Reciproc | R | SEM | Mtwo and ProTaper Universal > Reciproc | |
| Mn incisor | 75 | ProTaper Universal | CR | SEM | ProTaper Universal and WaveOne > ProTaper Next and Twisted File Adaptive | |
| Mn incisor | 105 | Twisted File Adaptive | CR/R/AM | SEM | RC and Adaptive Movement > R | |
| Mn premolar | 70 | Reciproc | R | SEM | No significance difference | |
| Mn molar | 20 | ProTaper Next | CR | µCT | No formation of dentinal defects | |
| Mn premolar and molar | 280 | WaveOne | R | SEM | WaveOne and ProTaper Universal > Twisted File and Twisted File Adaptive | |
| Mn molar | 30 | Reciproc | R | µCT | No significance difference | |
| Mn incisor | 100 | Mtwo | CR | SEM | WaveOne and Reciproc > Mtwo and ProTaper |
Mn, mandible; Mx, maxillar; MI, manual instrumentation; AM, adaptive movement; CR, continuous rotation; R, reciprocating; CT, computed tomography; CBCT, cone beam computed tomography; SEM, scanning electron microscopy.