Literature DB >> 22414846

Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne.

Hyeon-Cheol Kim1, Sang-Won Kwak, Gary Shun-Pan Cheung, Dae-Hoon Ko, Se-Min Chung, WooCheol Lee.   

Abstract

INTRODUCTION: The use of reciprocating movement was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison with continuous rotation. Recently 2 new brands of NiTi files have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these 2 files, Reciproc and WaveOne.
METHODS: Cyclic fatigue test with a simultaneous pecking motion was performed with the instrument (n = 10 each) operating in the recommended reciprocation motion until fracture for the Reciproc R25 and WaveOne Primary files. ProTaper F2 was tested in continuous rotation to serve as a control for comparison. The number of cycles to fracture (NCF) was determined by measuring the time to fracture. The length of the fragment was measured and the fracture surface was examined by using scanning electron microscopy. Torsional strength was measured by using a torsiometer after fixing the apical 5 mm of the instrument rigidly. Statistical analysis was performed by using one-way analysis of variance.
RESULTS: The results showed that Reciproc had a higher NCF and WaveOne had a higher torsional resistance than the others. Both reciprocating files demonstrated significantly higher cyclic fatigue and torsional resistances than ProTaper (P < .05). The fractographic analysis showed typical features of cyclic fatigue and torsional failure for all instruments.
CONCLUSIONS: The 2 brands of NiTi file for use with a reciprocation motion seem to have superior mechanical properties. Copyright Â
© 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22414846     DOI: 10.1016/j.joen.2011.11.014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  63 in total

1.  Cyclic fatigue of instruments for endodontic glide path.

Authors:  Gianluca Gambarini; Gianluca Plotino; GianPaolo Sannino; Nicola Maria Grande; Alessio Giansiracusa; Lucila Piasecki; Ulisses Xavier da Silva Neto; Dina Al-Sudani; Luca Testarelli
Journal:  Odontology       Date:  2013-11-07       Impact factor: 2.634

2.  "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.

Authors:  N Tulasi Priya; Veeramachaneni Chandrasekhar; S Anita; Muralidhar Tummala; T B Phanindhar Raj; Vijetha Badami; Pradeep Kumar; E Soujanya
Journal:  J Clin Diagn Res       Date:  2014-12-05

3.  Metallurgical analysis and fatigue resistance of WaveOne and ProTaper nickel-titanium instruments.

Authors:  Chiara Pirani; Oddone Ruggeri; Pier Paolo Cirulli; Gian Andrea Pelliccioni; Maria Giovanna Gandolfi; Carlo Prati
Journal:  Odontology       Date:  2013-04-09       Impact factor: 2.634

4.  Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system.

Authors:  Daniely Amorin Meireles; Mariana Mena Barreto Bastos; André Augusto Franco Marques; Lucas da Fonseca Roberti Garcia; Emílio Carlos Sponchiado
Journal:  Restor Dent Endod       Date:  2013-08-23

5.  A Comparative Study of Shaping Ability of four Rotary Systems.

Authors:  Jorge Rubio; José Ignacio Zarzosa; Antonio Pallarés
Journal:  Acta Stomatol Croat       Date:  2015-12

6.  Mechanical resistance of carbon and stainless steel hand instruments used in a reciprocating handpiece.

Authors:  Lucila Piasecki; Dina Al-Sudani; Alessio Giansiracusa Rubini; Giampaolo Sannino; Giampaolo Sonnino; Maurizio Bossù; Luca Testarelli; Roberto Di Giorgio; Ulisses Xavier da Silva-Neto; Christian Giampietro Brandão; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

7.  Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments.

Authors:  Murilo Priori Alcalde; Marco Antonio Hungaro Duarte; Clovis Monteiro Bramante; Bruno Carvalho de Vasconselos; Mario Tanomaru-Filho; Juliane Maria Guerreiro-Tanomaru; Jader Camilo Pinto; Marcus Vinicius Reis Só; Rodrigo Ricci Vivan
Journal:  Clin Oral Investig       Date:  2017-12-09       Impact factor: 3.573

8.  The influence of three different instrumentation techniques on the incidence of postoperative pain after endodontic treatment.

Authors:  Gianluca Gambarini; Luca Testarelli; Massimo De Luca; Valerio Milana; Gianluca Plotino; Nicola Maria Grande; Alessio Giansiracusa Rubini; Dina Al Sudani; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2013-03-20

9.  Preference of undergraduate students after first experience on nickel-titanium endodontic instruments.

Authors:  Sang Won Kwak; Gary Shun-Pan Cheung; Jung-Hong Ha; Sung Kyo Kim; Hyojin Lee; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2016-06-23

10.  A comparative study of mechanical resistance of two reciprocating files.

Authors:  Dario Di Nardo; Massimo Galli; Antonio Morese; Marco Seracchiani; Valerio Ferri; Gabriele Miccoli; Gianluca Gambarini; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-03-01
View more