Literature DB >> 22152631

Metallurgical characterization of M-Wire nickel-titanium shape memory alloy used for endodontic rotary instruments during low-cycle fatigue.

Jia Ye1, Yong Gao.   

Abstract

INTRODUCTION: Rotary instruments made of a new nickel-titanium (NiTi) alloy (M-Wire) have shown improved cyclic fatigue resistance and mechanical properties compared with those made of conventional superelastic NiTi wires. The objective of this study was to characterize microstructural changes of M-Wire throughout the cyclic fatigue process under controlled strain amplitude.
METHODS: The average fatigue life was calculated from 30 M-Wire samples that were subjected to a strain-controlled (≈ 4%) rotating bend fatigue test at room temperature and rotational speed of 300 rpm. Microstructural evolution of M-Wire has been investigated by different metallurgical characterization techniques, including differential scanning calorimetry, Vickers microhardness, and transmission electron microscopy at 4 different stages (as-received state, 30%, 60%, and 90% of average fatigue life).
RESULTS: During rotating bend fatigue test, no statistically significant difference (P > .05) was found on austenite finish temperatures between as-received M-Wire and fatigued samples. However, significant differences (P < .05) were observed on Vickers microhardness for samples with 60% and 90% fatigue life compared with as-received and 30% fatigue life. Coincidentally, substantial growth of martensite grains and martensite twins was observed in microstructure under transmission electron microscopy after 60% fatigue life.
CONCLUSIONS: The results of the present study suggested that endodontic instruments manufactured with M-Wire are expected to have higher strength and wear resistance than similar instruments made of conventional superelastic NiTi wires because of its unique nano-crystalline martensitic microstructure.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22152631     DOI: 10.1016/j.joen.2011.09.028

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  32 in total

1.  Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Authors:  Ana Arias; Rupinderpal Singh; Ove A Peters
Journal:  Odontology       Date:  2015-02-21       Impact factor: 2.634

2.  Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Authors:  Gianluca Plotino; Luca Testarelli; Dina Al-Sudani; Gianlcarlo Pongione; Nicola M Grande; Gianluca Gambarini
Journal:  Odontology       Date:  2012-10-18       Impact factor: 2.634

3.  Influence of cyclic loading in NiTi austenitic and R-phase endodontic files from a finite element perspective.

Authors:  Suzanny C S Martins; Jessica D Silva; Paula R Garcia; Ana C D Viana; Vicente T L Buono; Leandro A Santos
Journal:  Clin Oral Investig       Date:  2022-01-17       Impact factor: 3.573

4.  Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel-titanium endodontic instruments.

Authors:  Felipe Augusto Restrepo-Restrepo; Viviana Andrea Holguín-Vásquez; Syldana Julieth Cañas-Jiménez; Paula Andrea Villa-Machado; Sara Ochoa-Soto; Claudia Patricia Ossa-Orozco; Sergio Iván Tobón-Arroyave
Journal:  Dent Res J (Isfahan)       Date:  2021-06-22

5.  Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files.

Authors:  Charlotte Gouédard; Laurent Pino; Reza Arbab-Chirani; Shabnam Arbab-Chirani; Valérie Chevalier
Journal:  Restor Dent Endod       Date:  2022-03-04

6.  Canal shaping with WaveOne reciprocating files: influence of operator experience on instrument breakage and canal preparation time.

Authors:  Luigi Generali; Elena Righi; Maria Vittoria Todesca; Ugo Consolo
Journal:  Odontology       Date:  2013-06-28       Impact factor: 2.634

7.  Apical transportation of manual NiTi instruments and a hybrid technique in severely curved simulated canals.

Authors:  Aurenaila Nascimento Gonçalves; Matheus Franco da Frota; Emilio Carlos Sponchiado Júnior; Fredson Marcio Acris de Carvalho; Lucas da Fonseca Roberti Garcia; André Augusto Franco Marques
Journal:  J Conserv Dent       Date:  2015 Nov-Dec

8.  Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals.

Authors:  Giuseppe Troiano; Mario Dioguardi; Armando Cocco; Michele Giuliani; Cristiano Fabiani; Alfonso D'Alessandro; Domenico Ciavarella; Lorenzo Lo Muzio
Journal:  ScientificWorldJournal       Date:  2016-12-08

9.  An in vitro cyclic fatigue resistance comparison of conventional and new generation nickel-titanium rotary files.

Authors:  Celia Ruiz-Sánchez; Vicente Faus-Matoses; Teresa Alegre-Domingo; Ignacio Faus-Matoses; Vicente-José Faus-Llácer
Journal:  J Clin Exp Dent       Date:  2018-08-01

10.  Influence of three Ni-Ti cleaning and shaping files on postinstrumentation endodontic pain: A triple-blinded, randomized, controlled trial.

Authors:  Jogikalmat Krithikadatta; Vadhana Sekar; Paramanantham Sudharsan; Natanasabapathy Velumurugan
Journal:  J Conserv Dent       Date:  2016 Jul-Aug
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.