Literature DB >> 26963207

Micro-CT Evaluation of Non-instrumented Canal Areas with Different Enlargements Performed by NiTi Systems.

Gustavo De-Deus1, Felipe Gonçalves Belladonna2, Emmanuel João Nogueira Leal Silva1, Juliana Roter Marins1, Erick Miranda Souza3, Renata Perez1, Ricardo Tadeu Lopes4, Marco Aurélio Versiani5, Sidnei Paciornik6, Aline de Almeida Neves7.   

Abstract

The aim of this study was to compare the percentage of non-instrumented area of root canals prepared with different enlargements using single-file reciprocating systems (Reciproc and WaveOne) and a conventional multi-file rotary (BioRaCe) system by micro-computed tomographic analysis. Thirty mesial roots of mandibular molars with moderate curvature (10° to 20°) presenting a type II Vertucci canal configuration and similar internal volume were chosen and scanned at an isotropic resolution of 14.16 µm. The sample was assigned to 3 groups (n=10) according to the system used for root canal preparation: Reciproc, WaveOne, and BioRaCe groups. Second and third scans were taken after the canals were prepared with instruments sizes 25 and 40, respectively. The recorded images of the surface area voxels of the canals, before and after preparation were examined from the furcation level to the apex to quantify the non-instrumented surface. Statistical data were compared using GLM for repeated-measures with a significance level set at 5%. Instrumentation systems did not influence the percentage of untouched root canal surfaces (p=0.690) whilst a significant reduction in the percentage of static voxels was observed after the enlargement of the root canal (p=0.010) in all groups (p=0.507). None of the systems was able to prepare the entire surface area of the mesial root canal of mandibular molars. The increased final apical size resulted in a significant positive effect on the shaping ability of the tested systems.

Mesh:

Substances:

Year:  2015        PMID: 26963207     DOI: 10.1590/0103-6440201300116

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  9 in total

1.  Shaping ability of rotary or reciprocating systems for oval root canal preparation: a micro-computed tomography study.

Authors:  Camila Galletti Espir; Camila Almeida Nascimento-Mendes; Juliane Maria Guerreiro-Tanomaru; Bruno Cavalini Cavenago; Marco Antonio Hungaro Duarte; Mário Tanomaru-Filho
Journal:  Clin Oral Investig       Date:  2018-03-10       Impact factor: 3.573

2.  Clinical and microbiological effects of ultrasonically activated irrigation versus syringe irrigation during endodontic treatment: a systematic review and meta-analysis of randomized clinical trials.

Authors:  Noha Tawfik Ali; Randa Mohamed El-Boghdadi; Ahmed Mohamed Ibrahim; Suzan Abdul Wanees Amin
Journal:  Odontology       Date:  2021-11-03       Impact factor: 2.885

3.  Comparison of Shaping Ability of 10 Rotary and Reciprocating Systems: an In Vitro Study with AutoCad.

Authors:  Jorge Rubio; José Ignacio Zarzosa; Antonio Pallarés
Journal:  Acta Stomatol Croat       Date:  2017-09

4.  Evaluation of Mesial Root Canals of Mandibular Molars Obturated with Gutta-Percha and Resilon Techniques.

Authors:  Bruno Cavalini Cavenago; Aldo Enrique Del Carpio-Perochena; Pablo Andrés Amoroso-Silva; Murilo Priori Alcalde; Samuel Lucas Fernandes; Rodrigo Ricci Vivan; Marco Antonio Hungaro Duarte
Journal:  Eur Endod J       Date:  2017-06-30

5.  Efficacy of reciprocating instruments and final irrigant activation protocols on retreatment of mesiobuccal roots of maxillary molars: a micro-CT analysis.

Authors:  Lilian Tietz; Renan Diego Furlan; Ricardo Abreu da Rosa; Marco Antonio Hungaro Duarte; Murilo Priori Alcalde; Rodrigo Ricci Vivan; Theodoro Weissheimer; Marcus Vinicius Reis Só
Journal:  Restor Dent Endod       Date:  2022-02-15

6.  A Multimethod Assessment of a New Customized Heat-Treated Nickel-Titanium Rotary File System.

Authors:  Emmanuel J N L Silva; Jorge N R Martins; Natasha C Ajuz; Henrique S Antunes; Victor T L Vieira; Francisco M Braz Fernandes; Felipe G Belladonna; Marco A Versiani
Journal:  Materials (Basel)       Date:  2022-07-31       Impact factor: 3.748

7.  Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT study.

Authors:  Emmanuel João Nogueira Leal da Silva; Sara Gomes de Moura; Carolina Oliveira de Lima; Ana Flávia Almeida Barbosa; Waleska Florentino Misael; Mariane Floriano Lopes Santos Lacerda; Luciana Moura Sassone
Journal:  Restor Dent Endod       Date:  2021-02-25

Review 8.  Influence of File Motion on Shaping, Apical Debris Extrusion and Dentinal Defects: A Critical Review.

Authors:  Victor Feliz Pedrinha; Juliana Melo da Silva Brandão; Oscar Faciola Pessoa; Patrícia de Almeida Rodrigues
Journal:  Open Dent J       Date:  2018-02-28

Review 9.  An Update on Nickel-Titanium Rotary Instruments in Endodontics: Mechanical Characteristics, Testing and Future Perspective-An Overview.

Authors:  Alessio Zanza; Maurilio D'Angelo; Rodolfo Reda; Gianluca Gambarini; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2021-12-16
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.