Literature DB >> 26328961

Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study.

Daniel Thor1, Torkel B Brismar2, Michael A Fischer2.   

Abstract

PURPOSE: To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast-to-noise ratio (CNR).
METHODS: Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m(2) with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64-slice DS-CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70 and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose.
RESULTS: The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16-26 kg/m(2)) and for all sizes (16-35 kg/m(2)) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%-107%, 23%-83%, and 6%-12%, respectively.
CONCLUSIONS: DS single energy CT can be used to reduce CM dose by 44%-53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual-energy CT allows reduction of CM dose by 20% at similar radiation dose as compared to a standard 120 kV single source.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26328961     DOI: 10.1118/1.4927791

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study.

Authors:  Robbert W van Hamersvelt; Nienke G Eijsvoogel; Casper Mihl; Pim A de Jong; Arnold M R Schilham; Nico Buls; Marco Das; Tim Leiner; Martin J Willemink
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-08       Impact factor: 2.357

2.  Regarding Iodixanol for Pediatric CTA. Comment on Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation-Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949.

Authors:  Ulf Nyman; Peter Aspelin
Journal:  Children (Basel)       Date:  2022-05-10

3.  Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT.

Authors:  Marian S Solbak; Mette K Henning; Andrew England; Anne C Martinsen; Trond M Aaløkken; Safora Johansen
Journal:  Eur Radiol Exp       Date:  2020-09-11

4.  Low kV Computed Tomography of Parenchymal Abdominal Organs-A Systematic Animal Study of Different Contrast Media Injection Protocols.

Authors:  Daniel Overhoff; Gregor Jost; Michael McDermott; Olaf Weber; Hubertus Pietsch; Stefan O Schoenberg; Ulrike Attenberger
Journal:  Tomography       Date:  2021-11-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.