Literature DB >> 33936965

Feasibility of low-dose contrast media in run-off CT angiography on dual-layer spectral detector CT.

Haiyan Ren1, Yanhua Zhen1, Zheng Gong1, Chuanzhuo Wang1, Zhihui Chang1, Jiahe Zheng1.   

Abstract

BACKGROUND: The aim of the present study was to assess the feasibility of applying low-dose contrast media (CM), and to explore the optimal virtual monoenergetic images (VMIs) in run-off computed tomography (CT) angiography (CTA) on dual-layer spectral detector CT (SDCT).
METHODS: Forty patients were randomly assigned into a control group using routine volume CM (group A) and an experimental group using half-volume CM (group B). In groups A and B, 120 kVp polychromatic conventional images were generated via hybrid iterative reconstruction algorithm defined as A1 and B1, respectively. Additionally, in group B, VMIs (range, 40-120 keV) were reconstructed via a spectral reconstruction algorithm defined as B2-B10. Vascular attenuation, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and radiation dose were evaluated. Subjective evaluation was performed using a 5-point scale.
RESULTS: The patient demographics and radiation dose demonstrated no significant difference between groups A and B [dose length product (DLP): 1,823.45±512.68 vs. 2,014.40±453.25 mGy·cm, P=0.229; volume CT dose index: 14.92±3.40 vs. 16.26±2.85 mGy, P=0.208; the effective dose (ED): 10.82±3.02 vs. 11.88±2.67 mSv, P=0.229]. The mean vascular attenuation was higher in group B2 (40 keV) and was lower in group B3 (50 keV) in comparison with that in group A1 (487.07±154.21 vs. 414.35±71.66 HU, 329.90±100.25 vs. 414.35±71.66 HU, P>0.05). Compared with group A1, the mean noise was similar in group B2 (40 keV) and was lower in group B1 and groups B3-B10 (50-120 keV) (14.81±5.67 vs. 17.29±4.70 HU, P>0.05; 6.75±1.23-11.26±3.24 vs. 17.29±4.70 HU, P<0.05). The mean SNR and CNR in group B2 (40 keV), as well as the mean SNR in group B3 (50 keV), were significantly higher than those of group A1 (38.21±7.52 vs. 28.25±7.20, 32.70±7.79 vs. 24.54±6.60, 32.85±7.10 vs. 28.25±7.20, P<0.05), and the mean CNR in group B3 (50 keV) was similar to that in group A1 (26.66±7.32 vs. 24.54±6.60, P>0.05). Scores of subjective image quality (IQ) in group B2 (40 keV) and B3 (50 keV) were similar to those in group A1 {5 [4.25, 5] vs. 5 [4, 5], 5 [5, 5] vs. 5 [4, 5], P>0.05}, and showed a declining trend in group B4 (60 keV) {4 [4, 5] vs. 5 [4, 5], P>0.05}.
CONCLUSIONS: It is feasible to perform run-off CTA using low-dose CM with VMI on SDCT. The VMIs at 40-50 keV were the optimal choice and did not compromise IQ. 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Spectral detector computed tomography; contrast media (CM); lower extremity; virtual monoenergetic images (VMIs)

Year:  2021        PMID: 33936965      PMCID: PMC8047342          DOI: 10.21037/qims-20-925

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  25 in total

1.  Dual-energy CT: a phantom comparison of different platforms for abdominal imaging.

Authors:  Thorsten Sellerer; Peter B Noël; Manuel Patino; Anushri Parakh; Sebastian Ehn; Sascha Zeiter; Jasmin A Holz; Johannes Hammel; Alexander A Fingerle; Franz Pfeiffer; David Maintz; Ernst J Rummeny; Daniela Muenzel; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2018-02-05       Impact factor: 5.315

2.  Low contrast material dose coronary computed tomographic angiography using a dual-layer spectral detector system in patients at risk for contrast-induced nephropathy.

Authors:  Seitaro Oda; Hiroko Takaoka; Kazuhiro Katahira; Keiichi Honda; Takeshi Nakaura; Yasunori Nagayama; Narumi Taguchi; Masafumi Kidoh; Daisuke Utsunomiya; Yoshinori Funama; Katsuo Noda; Shuichi Oshima; Yasuyuki Yamashita
Journal:  Br J Radiol       Date:  2018-11-14       Impact factor: 3.039

3.  Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner.

Authors:  Kevin Kalisz; Negin Rassouli; Amar Dhanantwari; David Jordan; Prabhakar Rajiah
Journal:  Eur J Radiol       Date:  2017-11-10       Impact factor: 3.528

4.  A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography.

Authors:  Stefanie Mangold; Carlo N De Cecco; U Joseph Schoepf; Ricardo T Yamada; Akos Varga-Szemes; Andrew C Stubenrauch; Damiano Caruso; Stephen R Fuller; Thomas J Vogl; Konstantin Nikolaou; Thomas M Todoran; Julian L Wichmann
Journal:  Eur Radiol       Date:  2016-03-09       Impact factor: 5.315

5.  Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study.

Authors:  Robbert W van Hamersvelt; Nienke G Eijsvoogel; Casper Mihl; Pim A de Jong; Arnold M R Schilham; Nico Buls; Marco Das; Tim Leiner; Martin J Willemink
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-08       Impact factor: 2.357

6.  Virtual Monochromatic Dual-Energy Aortoiliac CT Angiography With Reduced Iodine Dose: A Prospective Randomized Study.

Authors:  Manuel Patino; Anushri Parakh; Grace C Lo; Mukta Agrawal; Avinash R Kambadakone; George R Oliveira; Dushyant V Sahani
Journal:  AJR Am J Roentgenol       Date:  2018-11-26       Impact factor: 3.959

7.  Does safe dosing of iodinated contrast prevent contrast-induced acute kidney injury?

Authors:  Jeremiah R Brown; John F Robb; Clay A Block; Anton C Schoolwerth; Aaron V Kaplan; Gerald T O'Connor; Richard J Solomon; David J Malenka
Journal:  Circ Cardiovasc Interv       Date:  2010-06-29       Impact factor: 6.546

Review 8.  X-ray-computed tomography contrast agents.

Authors:  Hrvoje Lusic; Mark W Grinstaff
Journal:  Chem Rev       Date:  2012-12-05       Impact factor: 60.622

9.  The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media.

Authors:  Xin Huang; Sizhe Gao; Yue Ma; Xiaomei Lu; Zheng Jia; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2020-03

Review 10.  Detector-based spectral CT with a novel dual-layer technology: principles and applications.

Authors:  Negin Rassouli; Maryam Etesami; Amar Dhanantwari; Prabhakar Rajiah
Journal:  Insights Imaging       Date:  2017-10-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.