Literature DB >> 20142749

Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: phantom and preliminary studies.

Kyung Su Kim1, Jeong Min Lee, Seung Ho Kim, Kyung Won Kim, Soo Jin Kim, Seung Hyun Cho, Joon Koo Han, Byung Ihn Choi.   

Abstract

OBJECTIVE: This study was designed to determine the optimal blending method and parameters to fuse computed tomography (CT) data sets with different energy levels in dual-energy CT (DECT) for the detection of hypervascular liver lesions.
MATERIALS AND METHODS: A liver agar phantom containing 8 conical tubes with various concentrations of contrast material, was scanned using a Somatom Definition Dual Source CT (DSCT; Siemens, Forchheim, Germany) scanner in the dual energy mode at different current settings. CT data sets obtained at voltage potentials of 80 kVp and 140 kVp were fused using the linear blending method and nonlinear method with different weighting factors (0.1, 0.3, 0.5, 0.7, and 0.9) and different parameters sets (A--lambda: 20, omega: 430; B--lambda: 20, omega: 70; C--lambda: 250, omega: 430; D--lambda: 250, omega: 70). In 20 patients with hepatocellular carcinomas, multiphasic liver CT scans including arterial, portal, and equilibrium phases were performed. DECT was used only during the arterial phase but a voltage potential of 120 kVp was used for both the portal and equilibrium phases. For quantitative analyses of the phantom and patient study, the contrast-to-noise ratio (CNR) of the lesion to liver on arterial phase images, was measured. For qualitative analysis of the CT images of the 20 study patients, 5 radiologists, each with a different level of clinical experience, independently assessed the 5 types of image sets regarding lesion conspicuity and overall image quality. This study followed the guidelines of our hospital's institutional review board, and patient informed written consent was not required. Statistical comparisons were made using repeated measures ANOVA with Bonferroni correction for multiple comparisons.
RESULTS: For the phantom and patient studies, 2 linear images with weighting factors 0.5 and 0.7 and 2 nonlinear images with a wide width, showed a higher CNR of hyperattenuated lesions than a standard 0.3 weighting factor linear blended image (P < 0.05). For the patient study, a weighting factor 0.5 and a 0.7 linear mixing image had a 9.2% and an 11.8% increase in CNR, respectively, more than a 0.3 linear blended image (P < 0.05). Moreover, a nonlinear mixing image with parameters A and C had a 14.0% increase in CNR over that of a 0.3 linear blended image (P < 0.05). In a qualitative study performed by the 5 reviewers, the nonlinear blended image set with a low level and wide width, was estimated as the most preferred image set (55%-100%), whereas a weighting factor of a 0.3 linear blended image was determined as the least preferred image (65%-100%).
CONCLUSIONS: Linear blended images with a higher weighting factor than 0.5 and nonlinear blended images with a wide width are able to provide improved lesion-to-liver CNR over the standard linear blending method (with a weighting factor of 0.3). Furthermore, the linear blending method with a low level and a high width provided the most preferred image set for hypervascular hepatocellular carcinoma detection by our radiologists.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20142749     DOI: 10.1097/RLI.0b013e3181d32119

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  19 in total

1.  Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality.

Authors:  Lifeng Yu; Jodie A Christner; Shuai Leng; Jia Wang; Joel G Fletcher; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kVp acquisition.

Authors:  A M Tawfik; J M Kerl; A A Razek; R W Bauer; N E Nour-Eldin; T J Vogl; M G Mack
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-08       Impact factor: 3.825

3.  Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study.

Authors:  Robbert W van Hamersvelt; Nienke G Eijsvoogel; Casper Mihl; Pim A de Jong; Arnold M R Schilham; Nico Buls; Marco Das; Tim Leiner; Martin J Willemink
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-08       Impact factor: 2.357

4.  Comparing image quality of single- and dual-energy computed tomography of the brain.

Authors:  Doris Dodig; Slavica Kovačić; Zrinka Matana Kaštelan; Iva Žuža; Filip Benić; Jurković Slaven; Damir Miletić; Zoran Rumboldt
Journal:  Neuroradiol J       Date:  2020-04-21

5.  Reduction of peristalsis-related gastrointestinal streak artifacts with dual-energy CT: a patient and phantom study.

Authors:  Sebastian Winklhofer; Jack W Lambert; Zhen Jane Wang; Yuxin Sun; Robert G Gould; Ronald J Zagoria; Benjamin M Yeh
Journal:  Abdom Radiol (NY)       Date:  2016-08

6.  Fused monochromatic imaging acquired by single source dual energy CT in hepatocellular carcinoma during arterial phase: an initial experience.

Authors:  Shun-Yu Gao; Xiao-Peng Zhang; Yong Cui; Ying-Shi Sun; Lei Tang; Xiao-Ting Li; Xiao-Yan Zhang; Jun Shan
Journal:  Chin J Cancer Res       Date:  2014-08       Impact factor: 5.087

Review 7.  New paradigm for management of hepatocellular carcinoma by imaging.

Authors:  Ijin Joo; Byung Ihn Choi
Journal:  Liver Cancer       Date:  2012-09       Impact factor: 11.740

8.  Non-linear blending of dual-energy CT data improves depiction of late iodine enhancement in chronic myocardial infarction.

Authors:  Julian L Wichmann; Xiaohan Hu; J Matthias Kerl; Boris Schulz; Boris Bodelle; Claudia Frellesen; Thomas Lehnert; Thomas J Vogl; Ralf W Bauer
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-09       Impact factor: 2.357

9.  Role of dual energy spectral computed tomography in characterization of hepatocellular carcinoma: Initial experience from a tertiary liver care institute.

Authors:  S T Laroia; Ajeet Singh Bhadoria; Yamini Venigalla; G K Chibber; Chagan Bihari; Archana Rastogi; S K Sarin
Journal:  Eur J Radiol Open       Date:  2016-07-20

10.  Comparative study of hepatic venography using non-linear-blending images, monochromatic images and low-voltage images of dual-energy CT.

Authors:  Q Wang; S Gaofeng; F Xueli; W Lijia; W Runze
Journal:  Br J Radiol       Date:  2014-07-23       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.