Literature DB >> 29380262

Multi-slice CT examinations of adult patients at Sudanese hospitals: radiation exposure based on size-specific dose estimates (SSDE).

Einas H Bashier1, I I Suliman2,3.   

Abstract

The aim of this study was to update the radiation exposure for adult patients undergoing multi-slice CT (MSCT) examinations using size-specific dose estimates (SSDE). Console, displayed CTDIvol and scan parameters were retrospectively recorded for 423 adult patients in seven Sudanese hospitals. Patient torso diameters were measured using digital calipers on the scanner console. SSDE was determined based on transverse images (SSDEtrans) and scout radiographs (SSDEsco). Size-specific conversion factors were used to translate the recorded CTDIvol into SSDE according to the procedure described in the American Association of Physicists in Medicine (AAPM) Report 204. In chest CT, mean CTDIvol, SSDEtrans and SSDEsco ranged: from 4.3 to 47.5 mGy (average: 12.8), 5.5 to 70.3 mGy (average: 18.6) and 5.8 to 63.5 mGy (average: 18.7), respectively. In abdominal CT, mean CTDIvol, SSDEtrans and SSDEsco ranged: from 4.0 to 74.5 mGy (average: 16), 5.5 to 152.8 mGy (average: 23.9) and 6.0 to 151.3 mGy (average: 25.21), respectively. Our study highlights the relationships between CT dose and patient dimensions measured from scout and transverse CT images. The correlations between the patient size and dose based on scout images were less significant than that based on transverse images. High dose levels and dose variations among hospitals reveal the need for standardization of scanning protocols and staff training on adoption of scanners' dose reduction techniques.

Entities:  

Keywords:  Computed tomography; Size-specific dose estimates (SSDE); Volume CT air kerma index

Mesh:

Year:  2018        PMID: 29380262     DOI: 10.1007/s11547-018-0859-6

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  19 in total

1.  A new look at CT dose measurement: beyond CTDI.

Authors:  Robert L Dixon
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

2.  Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

Authors:  Christopher P Favazza; Lifeng Yu; Shuai Leng; James M Kofler; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2015 May-Jun       Impact factor: 1.826

3.  CT dose index and patient dose: they are not the same thing.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Dianna D Cody; John M Boone; Michael F McNitt-Gray
Journal:  Radiology       Date:  2011-05       Impact factor: 11.105

4.  Comment on the "report of AAPM TG 204: size-specific dose estimates (SSDE) in pediatric and adult body CT examinations" [report of AAPM TG 204, 2011].

Authors:  Baojun Li; Richard H Behrman
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

5.  Patient radiation doses from adult and pediatric CT.

Authors:  Walter Huda; Awais Vance
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

6.  Survey of computed tomography technique and radiation dose in Sudanese hospitals.

Authors:  I I Suliman; S E Abdalla; Nada A Ahmed; M A Galal; Isam Salih
Journal:  Eur J Radiol       Date:  2011-01-14       Impact factor: 3.528

7.  The impact of patient table on size-specific dose estimate (SSDE).

Authors:  Choirul Anam; Freddy Haryanto; Rena Widita; Idam Arif; Geoff Dougherty; Donald McLean
Journal:  Australas Phys Eng Sci Med       Date:  2016-11-10       Impact factor: 1.430

8.  Size-specific dose estimates for adult patients at CT of the torso.

Authors:  Jodie A Christner; Natalie N Braun; Megan C Jacobsen; Rickey E Carter; James M Kofler; Cynthia H McCollough
Journal:  Radiology       Date:  2012-10-22       Impact factor: 11.105

9.  Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT: The Report of AAPM Task Group 220.

Authors:  Cynthia McCollough; Donovan M Bakalyar; Maryam Bostani; Samuel Brady; Kristen Boedeker; John M Boone; H Heather Chen-Mayer; Olav I Christianson; Shuai Leng; Baojun Li; Michael F McNitt-Gray; Roy A Nilsen; Mark P Supanich; Jia Wang
Journal:  AAPM Rep       Date:  2014-09

10.  Size-specific dose estimates: Localizer or transverse abdominal computed tomography images?

Authors:  Sarvenaz Pourjabbar; Sarabjeet Singh; Atul Padole; Akshay Saini; Michael A Blake; Mannudeep K Kalra
Journal:  World J Radiol       Date:  2014-05-28
View more
  2 in total

1.  Comparison of Application Value of Different Radiation Dose Evaluation Methods in Evaluating Radiation Dose of Adult Thoracic and Abdominal CT Scan.

Authors:  Jimin He; Guanwei Dong; Yi Deng; Jun He; ZhiGang Xiu; Fanzi Feng
Journal:  Front Surg       Date:  2022-03-25

2.  Comparison of central, peripheral, and weighted size-specific dose in CT.

Authors:  Choirul Anam; Dwi Adhianto; Heri Sutanto; Kusworo Adi; Mohd Hanafi Ali; William Ian Duncombe Rae; Toshioh Fujibuchi; Geoff Dougherty
Journal:  J Xray Sci Technol       Date:  2020       Impact factor: 1.535

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.