Literature DB >> 21237603

Survey of computed tomography technique and radiation dose in Sudanese hospitals.

I I Suliman1, S E Abdalla, Nada A Ahmed, M A Galal, Isam Salih.   

Abstract

The purpose of this study was to survey technique and radiation absorbed dose in CT examinations of adult in Sudan and to compare the results with the reference dose levels. Questionnaire forms were completed in nine hospitals and a sample of 445 CT examinations in patients. Information on patient, procedure, scanner, and technique for common CT examinations were collected. For each facility, the radiation absorbed dose was measured on CT dose phantom measuring 16 cm (head) and 32 cm (body) in diameter and was used to calculate the normalized CT air kerma index. Volume CT air kerma index (CVOL), CT air kerma-length product (PKL,CT) values were calculated using the measured normalized CT air kerma index and questionnaire information. The effective dose, E estimates was determined by using PKL,CT measurements and appropriate normalized coefficients. Assuming the sample to offer a fair representative picture of CT practice patterns in Sudan, the mean CVOL and PKL,CT values were comparable or below the reference doses: 65 mGy and 758 mGy cm, respectively at head CT; 11.5 mGy and 327 mGy cm, respectively at chest CT; 11.6 mGy and 437 mGy cm, respectively at abdominal CT; and 11.0 mGy and 264 mGy cm, respectively at pelvis CT. Estimated effective doses were 1.6, 4.6, 6.6 and 4.0 mSv, respectively. The study offered a first national dose survey and provided a mean for quality control and optimization of CT practice within the country.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21237603     DOI: 10.1016/j.ejrad.2010.12.050

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  3 in total

1.  Multi-slice CT examinations of adult patients at Sudanese hospitals: radiation exposure based on size-specific dose estimates (SSDE).

Authors:  Einas H Bashier; I I Suliman
Journal:  Radiol Med       Date:  2018-01-30       Impact factor: 3.469

2.  Survey of Thoracic CT Protocols and Technical Parameters in Korean Hospitals: Changes before and after Establishment of Thoracic CT Guideline by Korean Society of Thoracic Radiology in 2008.

Authors:  Ji-Won Kang; Kyung-Hyun Do; Kichang Han; Eun-Jin Chae; Dong-Hyun Yang; Choong-Wook Lee
Journal:  J Korean Med Sci       Date:  2016-02-03       Impact factor: 2.153

3.  Radiation doses with various body weights of phantoms in brain 128-slice MDCT examination.

Authors:  Hung-Chih Lin; Te-Jen Lai; Hsien-Chun Tseng; Ching-Hsiang Wang; Yen-Ling Tseng; Chien-Yi Chen
Journal:  J Radiat Res       Date:  2019-07-01       Impact factor: 2.724

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.