Literature DB >> 29285787

Artifact-reduced imaging of biopsy needles with 2D multispectral imaging.

Hans Weber1, Brian A Hargreaves1, Bruce L Daniel1.   

Abstract

PURPOSE: Magnetic resonance (MR) guidance for biopsy procedures requires high intrinsic soft-tissue contrast. However, artifacts induced by the metallic needle can reduce its localization and require low-susceptibility needle materials with poorer cutting performance. In a proof of concept, we demonstrate the feasibility of 2D multispectral imaging (2DMSI) for both needle tracking and for needle artifact reduction for more precise needle localization and to enable the usage of needle materials with higher susceptibility.
METHOD: We applied 2DMSI for imaging of MR-compatible biopsy needles, conventional stainless-steel needles, and mixed-material needles and compared it to conventional techniques. In addition, we exploited intrinsic off-resonance information for passive needle tracking.
RESULTS: 2DMSI achieved a stronger reduction of the needle artifact compared to conventional techniques. For the mixed-material needles, the artifact was reduced to a level below that for MR-compatible needles with conventional imaging. The passive tracking also improved the ability to pinpoint the needle.
CONCLUSION: 2DMSI is promising for both needle tracking and artifact-reduced imaging of biopsy needles for a more precise needle localization. 2DMSI may be particularly promising for needles inducing large distortions or for targeting of small lesions. In addition, it may enable the use of needle materials with higher susceptibility and potentially better sampling performance. Magn Reson Med 80:655-661, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  distortion correction; metal artifacts; metal-induced distortions; metallic implants; multispectral imaging; susceptibility artifact

Mesh:

Substances:

Year:  2017        PMID: 29285787      PMCID: PMC5910245          DOI: 10.1002/mrm.27056

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Management of biopsy needle artifacts: techniques for RF-refocused MRI.

Authors:  K Butts; J M Pauly; B L Daniel; S Kee; A M Norbash
Journal:  J Magn Reson Imaging       Date:  1999-04       Impact factor: 4.813

2.  Resistance forces acting on suture needles.

Authors:  T B Frick; D D Marucci; J A Cartmill; C J Martin; W R Walsh
Journal:  J Biomech       Date:  2001-10       Impact factor: 2.712

3.  Imaging near metal with a MAVRIC-SEMAC hybrid.

Authors:  K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

4.  A multispectral three-dimensional acquisition technique for imaging near metal implants.

Authors:  Kevin M Koch; John E Lorbiecki; R Scott Hinks; Kevin F King
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

5.  Biopsy needle susceptibility artifacts.

Authors:  M E Ladd; P Erhart; J F Debatin; B J Romanowski; P Boesiger; G C McKinnon
Journal:  Magn Reson Med       Date:  1996-10       Impact factor: 4.668

6.  2D multi-spectral imaging for fast MRI near metal.

Authors:  Brian A Hargreaves; Valentina Taviani; Daniel V Litwiller; Daehyun Yoon
Journal:  Magn Reson Med       Date:  2017-04-25       Impact factor: 4.668

7.  Characterization of surgical needles.

Authors:  J A von Fraunhofer; R J Storey; B J Masterson
Journal:  Biomaterials       Date:  1988-05       Impact factor: 12.479

8.  Instrument visualization using conventional and compressed sensing SEMAC for interventional MRI at 3T.

Authors:  Lena Sonnow; Wesley D Gilson; Esther Raithel; Mathias Nittka; Frank Wacker; Jan Fritz
Journal:  J Magn Reson Imaging       Date:  2017-09-21       Impact factor: 4.813

9.  SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Authors:  Wenmiao Lu; Kim Butts Pauly; Garry E Gold; John M Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

10.  Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation.

Authors:  J S Lewin; J L Duerk; V R Jain; C A Petersilge; C P Chao; J R Haaga
Journal:  AJR Am J Roentgenol       Date:  1996-06       Impact factor: 3.959

View more
  1 in total

1.  Minimal artifact actively shimmed metallic needles in MRI.

Authors:  Saikat Sengupta; Xinqiang Yan; Tamarya L Hoyt; Gary Drake; Anthony Gunderman; Yue Chen
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.