Management of biopsy needle artifacts: techniques for RF-refocused MRI.

K Butts1, J M Pauly, B L Daniel, S Kee, A M Norbash.   

Abstract

Several methods were investigated to improve the depiction of biopsy needles in radiofrequency (RF)-refocused magnetic resonance imaging. Distortion correction is performed by the use of view angle tilting (VAT): a gradient is employed on the slice-select axis during readout. Needle conspicuity is increased by offsetting the gradient echo from the spin echo and by inverting the 90 degrees RF pulse slice-select gradient. VAT effectively re-registers in-plane shifts. Since this method changes the projection angle through the slice, some structures appear blurred, while other structures appear sharper. VAT does not correct errors in slice selection. Offsetting the spin echo from the gradient echo increases needle conspicuity but can result in a shift in the apparent location of the needle. Inverting the 90 degrees slice-select gradient effectively increases the needle conspicuity with no shift in the needle location. These methods provide an easy and interactive means to manipulate needle artifacts but should be used cautiously.

Mesh:

Year:  1999        PMID: 10232519     DOI: 10.1002/(sici)1522-2586(199904)9:4<586::aid-jmri13>3.0.co;2-x

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  11 in total

1.  Modeling of active shimming of metallic needles for interventional MRI.

Authors:  Saikat Sengupta
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

2.  Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: feasibility, handling, and needle artefacts.

Authors:  Jens-Peter Kühn; Sönke Langner; Katrin Hegenscheid; Matthias Evert; Antje Kickhefel; Norbert Hosten; Ralf Puls
Journal:  Eur Radiol       Date:  2010-05-26       Impact factor: 5.315

3.  MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla.

Authors:  Elmar M Merkle; Brian M Dale; John Thomas; Erik K Paulson
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

4.  Improved field-mapping and artifact correction in multispectral imaging.

Authors:  Brady Quist; Xinwei Shi; Hans Weber; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

5.  Direct magnetic resonance imaging of histological tissue samples at 3.0T.

Authors:  Mark D Meadowcroft; Shutong Zhang; Wanzhan Liu; Bu Sik Park; James R Connor; Christopher M Collins; Michael B Smith; Qing X Yang
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

6.  View angle tilting echo planar imaging for distortion correction.

Authors:  Sinyeob Ahn; Xiaoping P Hu
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

7.  Artifact-reduced imaging of biopsy needles with 2D multispectral imaging.

Authors:  Hans Weber; Brian A Hargreaves; Bruce L Daniel
Journal:  Magn Reson Med       Date:  2017-12-29       Impact factor: 4.668

8.  MR imaging-guided laser ablation of osteoid osteomas with use of optical instrument guidance at 0.23 T.

Authors:  Roberto Blanco Sequeiros; Pekka Hyvönen; Alberto Blanco Sequeiros; Lasse Jyrkinen; Risto Ojala; Rauli Klemola; Teuvo Vaara; Osmo Tervonen
Journal:  Eur Radiol       Date:  2003-05-07       Impact factor: 5.315

9.  Spectrally resolved fully phase-encoded three-dimensional fast spin-echo imaging.

Authors:  Nathan S Artz; Diego Hernando; Valentina Taviani; Alexey Samsonov; Jean H Brittain; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Intraprocedural diffusion-weighted PROPELLER MRI to guide percutaneous biopsy needle placement within rabbit VX2 liver tumors.

Authors:  Jie Deng; Sumeet Virmani; Guang-Yu Yang; Richard Tang; Gayle Woloschak; Reed A Omary; Andrew C Larson
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.