Resistance forces acting on suture needles.

T B Frick1, D D Marucci, J A Cartmill, C J Martin, W R Walsh.   

Abstract

Understanding the resistance forces encountered by a suture needle during tissue penetration is important for the development of robotic surgical devices and virtual reality surgical simulators. Tensile forces applied to skin and tendon during suturing were measured. Fresh sheep achilles tendons were tensioned with a static load 4.9 N, 9.8 N or 19.6 N and sheepskin with 0.98 N, 2.9 N or 4.9 N static load. A straight 2/0 cutting suture needle in series with a load cell on a materials testing machine penetrated the tissue at 90 degrees with a velocity of 1, 5 or 10mm/s for each tissue tension (n=5). Continuous load versus displacement data was obtained and penetration load and stiffness were noted. The load versus displacement curve for skin during needle penetration demonstrated two characteristic peaks, corresponding to initial penetration and emergence of needle from the undersurface of the tissue. Increasing the tension within the tissue (skin and tendon) increased the amount of force required to penetrate the tissue with a suture needle (p<0.05). Needle displacement rate did not affect the resistance to needle penetration (p<0.05). This study provides a simple model for measuring force-feedback during needle penetration of soft tissues and is a good starting point for future studies of the penetration resistance properties of human tissues.

Entities:  

Mesh:

Year:  2001        PMID: 11522313     DOI: 10.1016/s0021-9290(01)00099-9

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  The analysis of forces needed for the suturing of elliptical skin wounds.

Authors:  Lukas Capek; Emmanuelle Jacquet; Ladislav Dzan; Antonin Simunek
Journal:  Med Biol Eng Comput       Date:  2011-12-27       Impact factor: 2.602

2.  DLR MiroSurge: a versatile system for research in endoscopic telesurgery.

Authors:  Ulrich Hagn; R Konietschke; A Tobergte; M Nickl; S Jörg; B Kübler; G Passig; M Gröger; F Fröhlich; U Seibold; L Le-Tien; A Albu-Schäffer; A Nothhelfer; F Hacker; M Grebenstein; G Hirzinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-06-13       Impact factor: 2.924

3.  Complication of a dorsal penile block: needle breakage and migration.

Authors:  Abhishek Mitra; Victor Palit; Michael Ferro; Calathur Nandakumar
Journal:  BMJ Case Rep       Date:  2009-02-16

4.  Artifact-reduced imaging of biopsy needles with 2D multispectral imaging.

Authors:  Hans Weber; Brian A Hargreaves; Bruce L Daniel
Journal:  Magn Reson Med       Date:  2017-12-29       Impact factor: 4.668

5.  Inter- and intraindividual variabilities of perforation forces of human and pig bowel tissue.

Authors:  E A M Heijnsdijk; M van der Voort; H de Visser; J Dankelman; D J Gouma
Journal:  Surg Endosc       Date:  2003-10-23       Impact factor: 4.584

6.  Design of a force-measuring setup for colorectal compression anastomosis and first ex-vivo results.

Authors:  Jana Steger; Isabella Patzke; Maximilian Berlet; Stefanie Ficht; Markus Eblenkamp; Petra Mela; Dirk Wilhelm
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-04-23       Impact factor: 3.421

Review 7.  Micro Electromechanical Systems (MEMS) Based Microfluidic Devices for Biomedical Applications.

Authors:  Muhammad Waseem Ashraf; Shahzadi Tayyaba; Nitin Afzulpurkar
Journal:  Int J Mol Sci       Date:  2011-06-07       Impact factor: 5.923

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.