Literature DB >> 29260880

Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist.

Hee Jin Park1, So Yeon Lee1, Kyung A Kang1, Eun Young Kim1, Hun Kyu Shin2, Se Jin Park2, Jai Hyung Park2, Eugene Kim2.   

Abstract

OBJECTIVE: To compare image quality of three-dimensional volume isotropic T2 weighted fast spin echo (3D VISTA) and two-dimensional (2D) T2 weighted images (T2WI) for evaluation of triangular fibrocartilage (TFC) and to investigate whether 3D VISTA can replace 2D T2 WI in evaluating TFC injury.
METHODS: This retrospective study included 69 patients who received wrist MRIs using both 2D T2 WI and 3D VISTA techniques for assessment of wrist pathology, including TFC injury. Two radiologists measured the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of the two sequences. The anatomical identification score and diagnostic performance were independently assessed by two interpreters. The diagnostic abilities of 3D VISTA and 2D T2 WI were analysed by sensitivity, specificity and accuracy for diagnosing TFC injury using surgically or clinically confirmed diagnostic reference standards.
RESULTS: 17 cases (25%) were classified as having TFC injury. 2 cases (12%) were diagnosed surgically, and 15 cases (88%) were diagnosed by physical examination. 52 cases (75%) were diagnosed as having intact TFC. 8 of these cases (15%) were surgically confirmed, while the others were diagnosed by physical examination and clinical findings. The 3D VISTA images had significantly higher SNR and CNR values for the TFC than 2D T2 WI images. The scores of 3D VISTA's total length, full width and sharpness were similar to those of 2D T2 WI. We were unable to find a significant difference between 3D VISTA and 2D T2 WI in the ability to diagnose TFC injury.
CONCLUSION: 3D VISTA image quality is similar to that of 2D T2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment. Advances in knowledge: 3D VISTA image quality is similar to that of 2D T2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment.

Entities:  

Mesh:

Year:  2018        PMID: 29260880      PMCID: PMC5965990          DOI: 10.1259/bjr.20170604

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  21 in total

1.  3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence.

Authors:  Jung Min Seo; Young Cheol Yoon; Jong Won Kwon
Journal:  Acta Radiol       Date:  2011-12-01       Impact factor: 1.990

2.  Three-dimensional isotropic T2-weighted cervical MRI at 3T: comparison with two-dimensional T2-weighted sequences.

Authors:  J W Kwon; Y C Yoon; S-H Choi
Journal:  Clin Radiol       Date:  2011-12-03       Impact factor: 2.350

3.  Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences.

Authors:  Joon-Yong Jung; Won-Hee Jee; Michael Y Park; So-Yeon Lee; Yang-Soo Kim
Journal:  Skeletal Radiol       Date:  2012-02-10       Impact factor: 2.199

4.  Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury.

Authors:  H J Park; S Y Lee; N H Park; M H Rho; E C Chung; J H Park; S J Park
Journal:  Clin Radiol       Date:  2016-01-14       Impact factor: 2.350

5.  Understanding interobserver agreement: the kappa statistic.

Authors:  Anthony J Viera; Joanne M Garrett
Journal:  Fam Med       Date:  2005-05       Impact factor: 1.756

6.  Lesions of the triangular fibrocartilage complex: MR findings with a three-dimensional gradient-recalled-echo sequence.

Authors:  S M Totterman; R J Miller; S E McCance; S P Meyers
Journal:  Radiology       Date:  1996-04       Impact factor: 11.105

7.  Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences.

Authors:  Hee Jin Park; So Yeon Lee; Noh Hyuck Park; Jin Hwan Ahn; Eun Chul Chung; Sung Jun Kim; Jang Gyu Cha
Journal:  Acta Radiol       Date:  2016-07-21       Impact factor: 1.990

8.  Usefulness of the oblique view of three-dimensional isotropic T2-weighted fast spin-echo (VISTA) in the evaluation of anterior cruciate ligament reconstruction.

Authors:  Jung Woo Yi; Hee Jin Park; So Yeon Lee; Myung Ho Rho; Eun Chul Chung; Mi Sung Kim; Jai Hyung Park; Se Jin Park
Journal:  Clin Imaging       Date:  2016-02-06       Impact factor: 1.605

9.  Origins and insertions of the triangular fibrocartilage complex: a histological study.

Authors:  T Nakamura; S Takayama; Y Horiuchi; Y Yabe
Journal:  J Hand Surg Br       Date:  2001-10

Review 10.  Recent advances in MRI of articular cartilage.

Authors:  Garry E Gold; Christina A Chen; Seungbum Koo; Brian A Hargreaves; Neal K Bangerter
Journal:  AJR Am J Roentgenol       Date:  2009-09       Impact factor: 3.959

View more
  4 in total

Review 1.  State-of-the-art magnetic resonance imaging sequences for pediatric body imaging.

Authors:  Mareen Sarah Kraus; Ailish C Coblentz; Vibhas S Deshpande; Johannes M Peeters; Pedro M Itriago-Leon; Govind B Chavhan
Journal:  Pediatr Radiol       Date:  2022-10-18

2.  Application of Contrast-Enhanced 3-Dimensional T2-Weighted Volume Isotropic Turbo Spin Echo Acquisition Sequence in the Diagnosis of Prolactin-Secreting Pituitary Microadenomas.

Authors:  Rui Guo; Yue Wu; Guangcheng Guo; Haiyang Zhou; Shoutang Liu; Zhenwei Yao; Yunping Xiao
Journal:  J Comput Assist Tomogr       Date:  2022 Jan-Feb 01       Impact factor: 1.826

3.  Artificial intelligence based image quality enhancement in liver MRI: a quantitative and qualitative evaluation.

Authors:  Marta Zerunian; Francesco Pucciarelli; Damiano Caruso; Michela Polici; Benedetta Masci; Gisella Guido; Domenico De Santis; Daniele Polverari; Daniele Principessa; Antonella Benvenga; Elsa Iannicelli; Andrea Laghi
Journal:  Radiol Med       Date:  2022-09-07       Impact factor: 6.313

4.  Improved diagnostic accuracy for ulnar-sided TFCC lesions with radial reformation of 3D sequences in wrist MR arthrography.

Authors:  Henner Huflage; Karsten Sebastian Luetkens; Andreas Steven Kunz; Nora Conrads; Rafael Gregor Jakubietz; Michael Georg Jakubietz; Lenhard Pennig; Lukas Goertz; Thorsten Alexander Bley; Rainer Schmitt; Jan-Peter Grunz
Journal:  Eur Radiol       Date:  2021-05-18       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.