Literature DB >> 25585852

Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences.

Hee Jin Park1, So Yeon Lee1, Noh Hyuck Park2, Jin Hwan Ahn3, Eun Chul Chung1, Sung Jun Kim4, Jang Gyu Cha5.   

Abstract

Background There has been no comparison study to assess the diagnostic efficacy of additional anterior cruciate ligament (ACL) views in three-dimensional (3D) volume isotropic turbo spin-echo acquisition (VISTA) and two-dimensional (2D) fast spin-echo (FSE) T2-weighted (T2W) images for the diagnosis of ACL tear. Purpose To compare the diagnostic performances of additional ACL views on VISTA with those on the 2D FSE T2W images. Material and Methods This retrospective study included 78 patients who were suspected to have ACL injury and underwent both 2D TSE T2W magnetic resonance imaging (MRI) and 3D VISTA MRI of the knee between November 2012 and March 2013. The diagnostic performance of each oblique sagittal and coronal view and the combined images was evaluated for sensitivity, specificity, and accuracy for diagnosing an ACL tear. The arthroscopically and clinically confirmed diagnoses were used as the reference standard. The values were statistically analyzed using the McNemar test. Results The inter-observer agreement between two readers of the additional ACL views on 3D VISTA and 2D FSE T2W images were substantial on 2D FSE images and nearly concurred on the VISTA image. When considering both views of the oblique sagittal and coronal images, the inter-observer agreement between readers nearly concurred. There were no statistically significant differences in the sensitivity, specificity, and accuracy between 2D FSE images and VISTA images. Conclusion The performance of the additional ACL view on 3D VISTA MRI is comparable to that of 2D FSE T2W MRI in the diagnosis of ACL tear though the image quality of the 3D VISTA MRI is not equal to that of 2D FSE MRI.

Entities:  

Keywords:  3D isotropic; Magnetic resonance imaging (MRI); VISTA; anterior cruciate ligament (ACL); knee

Mesh:

Substances:

Year:  2016        PMID: 25585852     DOI: 10.1177/0284185114568048

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  8 in total

1.  Preoperative magnetic resonance imaging predicts eligibility for arthroscopic primary anterior cruciate ligament repair.

Authors:  Jelle P van der List; Gregory S DiFelice
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-07-13       Impact factor: 4.342

2.  Can a single isotropic 3D fast spin echo sequence replace three-plane standard proton density fat-saturated knee MRI at 1.5 T?

Authors:  B Pass; P Robinson; R Hodgson; A J Grainger
Journal:  Br J Radiol       Date:  2015-06-12       Impact factor: 3.039

3.  Usefulness of oblique coronal magnetic resonance images of the knee after posterior cruciate ligament reconstruction.

Authors:  Hee J Park; So Y Lee; Hyun P Hong; Jin H Ahn; Jai H Park; Hun K Shin; Hye L Jung
Journal:  Br J Radiol       Date:  2016-06-21       Impact factor: 3.039

4.  Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury.

Authors:  Hee J Park; So Y Lee; Seon H Choi; Jin H Ahn; Se J Park; Jai H Park; Eugene Kim
Journal:  Br J Radiol       Date:  2016-09-21       Impact factor: 3.039

5.  Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist.

Authors:  Hee Jin Park; So Yeon Lee; Kyung A Kang; Eun Young Kim; Hun Kyu Shin; Se Jin Park; Jai Hyung Park; Eugene Kim
Journal:  Br J Radiol       Date:  2018-01-05       Impact factor: 3.039

6.  Comparison of two MR grading systems for correlation between grade of cervical neural foraminal stenosis and clinical manifestations.

Authors:  Kyu H Lee; Hee J Park; So Y Lee; Eun C Chung; Myung H Rho; Hyunchul Shin; Young J Kwon
Journal:  Br J Radiol       Date:  2016-03-23       Impact factor: 3.039

7.  Feasibility of synthetic MRI in knee imaging in routine practice.

Authors:  Sana Boudabbous; Angeliki Neroladaki; Ilias Bagetakos; Marion Hamard; Bénédicte Ma Delattre; Maria Isabel Vargas
Journal:  Acta Radiol Open       Date:  2018-05-11

8.  Assessment of the Usefulness of Image Reconstruction in the Oblique and Double-oblique Sagittal Planes for Magnetic Resonance Imaging of the Canine Cranial Cruciate Ligament.

Authors:  Adam Przeworski; Zbigniew Adamiak; Michał Nowicki; Marta Mieszkowska; Angelika Tobolska; Joanna Głodek
Journal:  J Vet Res       Date:  2021-05-16       Impact factor: 1.744

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.