Literature DB >> 22142499

Three-dimensional isotropic T2-weighted cervical MRI at 3T: comparison with two-dimensional T2-weighted sequences.

J W Kwon1, Y C Yoon, S-H Choi.   

Abstract

AIM: To compare three-dimensional (3D) isotropic T2-weighted magnetic resonance imaging (MRI) sequences and reformation with two-dimensional (2D) T2-weighted sequences regarding image quality of the cervical spine at 3T.
MATERIALS AND METHODS: A phantom study was performed using a water-filled cylinder. The signal-to-noise and image homogeneity were evaluated. Fourteen (n=14) volunteers were examined at 3T using 3D isotropic T2-weighted sagittal and conventional 2D T2-weighted sagittal, axial, and oblique sagittal MRI. Multiplanar reformation (MPR) of the 3D T2-weighted sagittal dataset was performed simultaneously with image evaluation. In addition to artefact assessment, the visibility of anatomical structures in the 3D and 2D sequences was qualitatively assessed by two radiologists independently. Cohen's kappa and Wilcoxon signed rank test were used for the statistical analysis. RESULT: The 3D isotropic T2-weighted sequence resulted in the highest signal-to-noise ratio (SNR) and lowest non-uniformity (NU) among the sequences in the phantom study. Quantitative evaluation revealed lower NU values of the cerebrospinal fluid (CSF) and muscles in 2D T2-weighted sagittal sequences compared to the 3D volume isotropic turbo spin-echo acquisition (VISTA) sequence. The other NU values revealed no statistically significant difference between the 2D turbo spin-echo (TSE) and 3D VISTA sequences (0.059<p<0.959). 3D VISTA images showed significantly fewer CSF flow artefacts (p<0.001) and better delineated intradural nerve rootlets (p=0.001) and neural foramina (p=0.016) compared to 2D sequences.
CONCLUSION: A 3D T2 weighted sequence is superior to conventional 2D sequences for the delineation of intradural nerve rootlets and neural foramina and is less affected by CSF flow artefacts.
Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22142499     DOI: 10.1016/j.crad.2011.06.011

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  13 in total

1.  [Utility of coronal oblique slices in cervical spine MRI: Improved detection of the neuroforamina].

Authors:  W Freund; S Klessinger; M Mueller; M-E Halatsch; G Hoepner; F Weber; B Schmitz
Journal:  Radiologe       Date:  2015-11       Impact factor: 0.635

2.  MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.

Authors:  Giovanni Foti; Paolo Avanzi; William Mantovani; Flavia Dal Corso; Emanuele Demozzi; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

3.  MR arthrography of the hip: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.

Authors:  Giovanni Foti; Antonio Campacci; Michele Conati; Mirko Trentadue; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2017-06-09       Impact factor: 3.469

4.  Comparison of oblique coronal images in knee of three-dimensional isotropic T2-weighted turbo spin echo MRI versus two-dimensional fast spin echo T2-weighted sequences for evaluation of posterior cruciate ligament injury.

Authors:  Hee J Park; So Y Lee; Seon H Choi; Jin H Ahn; Se J Park; Jai H Park; Eugene Kim
Journal:  Br J Radiol       Date:  2016-09-21       Impact factor: 3.039

5.  Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist.

Authors:  Hee Jin Park; So Yeon Lee; Kyung A Kang; Eun Young Kim; Hun Kyu Shin; Se Jin Park; Jai Hyung Park; Eugene Kim
Journal:  Br J Radiol       Date:  2018-01-05       Impact factor: 3.039

Review 6.  Clinical utility of optimized three-dimensional T1-, T2-, and T2*-weighted sequences in spinal magnetic resonance imaging.

Authors:  Nobuko Tanitame; Keizo Tanitame; Kazuo Awai
Journal:  Jpn J Radiol       Date:  2017-02-23       Impact factor: 2.374

7.  Fast and accurate semi-automated segmentation method of spinal cord MR images at 3T applied to the construction of a cervical spinal cord template.

Authors:  Mohamed-Mounir El Mendili; Raphaël Chen; Brice Tiret; Noémie Villard; Stéphanie Trunet; Mélanie Pélégrini-Issac; Stéphane Lehéricy; Pierre-François Pradat; Habib Benali
Journal:  PLoS One       Date:  2015-03-27       Impact factor: 3.240

8.  Characteristics of spondylotic myelopathy on 3D driven-equilibrium fast spin echo and 2D fast spin echo magnetic resonance imaging: a retrospective cross-sectional study.

Authors:  Mike A Abdulhadi; Joseph R Perno; Elias R Melhem; Paolo G P Nucifora
Journal:  PLoS One       Date:  2014-07-15       Impact factor: 3.240

9.  Comparison of three-dimensional isotropic and two-dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears.

Authors:  Ji Hyun Lee; Young Cheol Yoon; Sukkyung Jee; Jong Won Kwon; Jang Gyu Cha; Jae Chul Yoo
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

10.  Diagnosis of Nerve Root Compromise of the Lumbar Spine: Evaluation of the Performance of Three-dimensional Isotropic T2-weighted Turbo Spin-Echo SPACE Sequence at 3T.

Authors:  Jinkyeong Sung; Won-Hee Jee; Joon-Yong Jung; Jinhee Jang; Jin-Sung Kim; Young-Hoon Kim; Kee-Yong Ha
Journal:  Korean J Radiol       Date:  2017-01-05       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.