A generic framework to simulate realistic lung, liver and renal pathologies in CT imaging.

Justin Solomon1, Ehsan Samei.   

Abstract

Realistic three-dimensional (3D) mathematical models of subtle lesions are essential for many computed tomography (CT) studies focused on performance evaluation and optimization. In this paper, we develop a generic mathematical framework that describes the 3D size, shape, contrast, and contrast-profile characteristics of a lesion, as well as a method to create lesion models based on CT data of real lesions. Further, we implemented a technique to insert the lesion models into CT images in order to create hybrid CT datasets. This framework was used to create a library of realistic lesion models and corresponding hybrid CT images. The goodness of fit of the models was assessed using the coefficient of determination (R(2)) and the visual appearance of the hybrid images was assessed with an observer study using images of both real and simulated lesions and receiver operator characteristic (ROC) analysis. The average R(2) of the lesion models was 0.80, implying that the models provide a good fit to real lesion data. The area under the ROC curve was 0.55, implying that the observers could not readily distinguish between real and simulated lesions. Therefore, we conclude that the lesion-modeling framework presented in this paper can be used to create realistic lesion models and hybrid CT images. These models could be instrumental in performance evaluation and optimization of novel CT systems.

Mesh:

Year:  2014        PMID: 25325156     DOI: 10.1088/0031-9155/59/21/6637

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  Validation of a Projection-domain Insertion of Liver Lesions into CT Images.

Authors:  Baiyu Chen; Chi Ma; Shuai Leng; Jeff L Fidler; Shannon P Sheedy; Cynthia H McCollough; Joel G Fletcher; Lifeng Yu
Journal:  Acad Radiol       Date:  2016-07-16       Impact factor: 3.173

2.  Channelized Hotelling observer correlation with human observers for low-contrast detection in liver CT images.

Authors:  Alexandre Ba; Craig K Abbey; Damien Racine; Anaïs Viry; Francis R Verdun; Sabine Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-20

3.  Evaluation of Simulated Lesions as Surrogates to Clinical Lesions for Thoracic CT Volumetry: The Results of an International Challenge.

Authors:  Marthony Robins; Jayashree Kalpathy-Cramer; Nancy A Obuchowski; Andrew Buckler; Maria Athelogou; Rudresh Jarecha; Nicholas Petrick; Aria Pezeshk; Berkman Sahiner; Ehsan Samei
Journal:  Acad Radiol       Date:  2018-09-12       Impact factor: 3.173

4.  Design and fabrication of heterogeneous lung nodule phantoms for assessing the accuracy and variability of measured texture radiomics features in CT.

Authors:  Ehsan Samei; Jocelyn Hoye; Yuese Zheng; Justin B Solomon; Daniele Marin
Journal:  J Med Imaging (Bellingham)       Date:  2019-06-21

5.  Computational insertion of microcalcification clusters on mammograms: reader differentiation from native clusters and computer-aided detection comparison.

Authors:  Zahra Ghanian; Aria Pezeshk; Nicholas Petrick; Berkman Sahiner
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-19

6.  Evaluation of a projection-domain lung nodule insertion technique in thoracic computed tomography.

Authors:  Chi Ma; Lifeng Yu; Baiyu Chen; Chi Wan Koo; Edwin A Takahashi; Joel G Fletcher; David L Levin; Ronald S Kuzo; Lyndsay D Viers; Stephanie A Vincent-Sheldon; Shuai Leng; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-31

7.  Technical Note: Design and implementation of a high-throughput pipeline for reconstruction and quantitative analysis of CT image data.

Authors:  John Hoffman; Nastaran Emaminejad; Muhammad Wahi-Anwar; Grace H Kim; Matthew Brown; Stefano Young; Michael McNitt-Gray
Journal:  Med Phys       Date:  2019-04-03       Impact factor: 4.071

8.  Systematic analysis of bias and variability of morphologic features for lung lesions in computed tomography.

Authors:  Jocelyn Hoye; Justin Solomon; Thomas J Sauer; Marthony Robins; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2019-03-26

9.  Evaluation of a projection-domain lung nodule insertion technique in thoracic CT.

Authors:  Chi Ma; Baiyu Chen; Chi Wan Koo; Edwin A Takahashi; Joel G Fletcher; Cynthia H McCollough; David L Levin; Ronald S Kuzo; Lyndsay D Viers; Stephanie A Vincent Sheldon; Shuai Leng; Lifeng Yu
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-04-04

10.  CT reconstruction algorithms affect histogram and texture analysis: evidence for liver parenchyma, focal solid liver lesions, and renal cysts.

Authors:  Su Joa Ahn; Jung Hoon Kim; Sang Min Lee; Sang Joon Park; Joon Koo Han
Journal:  Eur Radiol       Date:  2018-11-19       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.