| Literature DB >> 29149844 |
Anna Carolina V Mello-Moura1,2, Carmela R Bresolin1, Cacio Moura-Netto3, André Ito4, Angela T Araki3, José Carlos P Imparato1,4, Fausto M Mendes5,6.
Abstract
BACKGROUND: Due to the scarcity of exfoliated/extracted human primary teeth with complete roots, artificial teeth were developed as an alternative to be used for educational and laboratory research purposes. This study aimed to assess the feasibility of using artificial primary teeth for conducting laboratory research through an experiment related to canal length determination, comparing artificial teeth with natural teeth.Entities:
Keywords: Artificial teeth; Canal length determination; Endodontics; Primary teeth
Mesh:
Year: 2017 PMID: 29149844 PMCID: PMC5693584 DOI: 10.1186/s12903-017-0420-3
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Fig. 1Visual and radiographic aspects of examples of artificial anterior (a) and posterior (c) primary teeth compared with natural anterior (b) and posterior (d) primary teeth
Inter- and intra-examiner reproducibility for natural and artificial anterior teeth among the methods used for canal length determination through Intraclass Correlation Coefficient calculation
| Methods for canal length determination | Intraexaminer reliability | Interexaminer reliability | ||
|---|---|---|---|---|
| Examiner 1 | Examiner 2 | 1st evaluation | 2nd evaluation | |
| ICC (95% CI) | ICC (95% CI) | ICC (95% CI) | ICC (95% CI) | |
| Natural anterior teeth ( | ||||
| Radiographic | 0.983 | 0.993 | 0.921 | 0.923 |
| Mini Apex | 0.974 | 0.992 | 0.909 | 0.943 |
| Root ZX | 0.994 | 0.988 | 0.959 | 0.959 |
| Artificial anterior teeth ( | ||||
| Radiographic | 0.982 | 0.968 | 0.939 | 0.960 |
| Mini Apex | 0.789 | 0.949 | 0.870 | 0.809 |
| Root ZX | 0.895 | 0.947 | 0.760 | 0.709 |
ICC Intraclass correlation coefficients, 95% CI 95% confidence intervals
Inter- and intra-examiner reproducibility for natural and artificial posterior teeth among the methods used for canal length determination through Intraclass Correlation Coefficient calculation
| Methods for root length determination | Intraexaminer reliability | Interexaminer reliability | ||
|---|---|---|---|---|
| Examiner 1 | Examiner 2 | 1st evaluation | 2nd evaluation | |
| ICC (95% CI) | ICC (95% CI) | ICC (95% CI) | ICC (95% CI) | |
| Natural posterior teeth ( | ||||
| Radiographic | 0.980 | 0.966 | 0.978 | 0.982 |
| Mini Apex | 0.984 | 0.995 | 0.933 | 0.936 |
| Root ZX | 0.986 | 0.992 | 0.949 | 0.933 |
| Artificial posterior teeth ( | ||||
| Radiographic | 0.976 | 0.983 | 0.912 | 0.929 |
| Mini Apex | 0.988 | 0.994 | 0.971 | 0.963 |
| Root ZX | 0.993 | 0.997 | 0.959 | 0.959 |
Intraclass correlation coefficients, 95% confidence intervals
Accuracy of the methods used for canal length determination through Intraclass Correlation Coefficient calculation and Bland-Altman analysis for natural and artificial anterior teeth
| Methods for canal length determination | ICC (95% CI) | Bland-Altman analysis | ||
|---|---|---|---|---|
| Mean difference | Upper limit | Lower limit | ||
| Natural anterior teeth ( | ||||
| Radiographic | 0.882 | −0.52 | 1.20 | −2.23 |
| Mini Apex | 0.962 | 0.22 | 1.20 | −0.77 |
| Root ZX | 0.945 | 0.42 | 1.42 | −0.58 |
| Artificial anterior teeth ( | ||||
| Radiographic | 0.518 | −0.87 | 0.72 | −2.45 |
| Mini Apex | 0.644 | 0.66 | 1.90 | −0.58 |
| Root ZX | 0.617 | 0.43 | 1.86 | −0.99 |
Intraclass correlation coefficients, 95% CI 95% confidence intervals
Accuracy of the methods used for canal length determination through Intraclass Correlation Coefficient calculation and Bland-Altman analysis for natural and artificial posterior teeth
| Methods for canal length determination | ICC (95% CI) | Bland-Altman analysis | ||
|---|---|---|---|---|
| Mean difference | Upper limit | Lower limit | ||
| Natural posterior teeth ( | ||||
| Radiographic | 0.685 | −0.40 | 2.90 | −3.70 |
| Mini Apex | 0.941 | 0.18 | 1.54 | −1.19 |
| Root ZX | 0.958 | 0.14 | 1.33 | −1.05 |
| Artificial posterior teeth ( | ||||
| Radiographic | 0.625 | −1.70 | 1.00 | −4.40 |
| Mini Apex | 0.959 | 0.29 | 1.45 | −0.88 |
| Root ZX | 0.947 | 0.40 | 1.64 | −0.85 |
Intraclass correlation coefficients, 95% CI 95% confidence intervals
Fig. 2Box-and-Whisker plots of absolute difference between the actual length and those obtained by the methods of root canal length determination (mm). Asterisks represent that the method presented statistical significant difference (p < 0.05 though Friedman test) from other methods considering the same group of teeth