Literature DB >> 23230644

Tooth embedding medium influences the accuracy of electronic apex locator.

Juliane M Guerreiro-Tanomaru1, Hugo R Croti, Guilherme F Silva, Gisele Faria, Mário Tanomaru-Filho.   

Abstract

This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.

Entities:  

Mesh:

Year:  2012        PMID: 23230644

Source DB:  PubMed          Journal:  Acta Odontol Latinoam        ISSN: 0326-4815


  6 in total

1.  Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability.

Authors:  Franck Diemer; Emma Plews; Marie Georgelin-Gurgel; Lora Mishra; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2022-01-23       Impact factor: 3.623

2.  Apexoconnection: A Novel Technique to Determine Working Length.

Authors:  Muslat A Bin Rubaia'an; Mohammed AbuHassna; Rahaf K AlShahrani; Khaled Alghulikah; Abdulrahman Dahham Alsaffan
Journal:  Clin Cosmet Investig Dent       Date:  2021-08-17

3.  Evaluation of Conventional Radiography and an Electronic Apex Locator in Determining the Working Length in C-shaped Canals.

Authors:  Hamid Jafarzadeh; Masoud Beyrami; Maryam Forghani
Journal:  Iran Endod J       Date:  2017

4.  Use of artificial primary teeth for endodontic laboratory research: experiments related to canal length determination.

Authors:  Anna Carolina V Mello-Moura; Carmela R Bresolin; Cacio Moura-Netto; André Ito; Angela T Araki; José Carlos P Imparato; Fausto M Mendes
Journal:  BMC Oral Health       Date:  2017-11-17       Impact factor: 2.757

5.  Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study.

Authors:  Thomas Gerhard Wolf; Anna Krauß-Mironjuk; Richard Johannes Wierichs; Benjamín Briseño-Marroquín
Journal:  Sci Rep       Date:  2021-02-08       Impact factor: 4.379

6.  In vitro Evaluation of the Accuracy of the Root Zx in the Presence of Naocl 2.5% and Chlorhexidine 0.2.

Authors:  Marjan Bolbolian; Siamak Golchin; Seyedmatin Faegh
Journal:  J Clin Exp Dent       Date:  2018-11-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.