Literature DB >> 20078703

Ex vivo performance of five methods for root canal length determination in primary anterior teeth.

A C V Mello-Moura1, C Moura-Netto, A T Araki, A C Guedes-Pinto, F M Mendes.   

Abstract

AIM: To evaluate in a laboratory setting the performance of five methods for the determination of root canal length in primary anterior teeth.
METHODOLOGY: Twenty extracted primary incisors, with at least two-thirds of the root, were used. After access cavity preparation, the teeth were embedded in alginate mixed with 0.9% sodium chloride solution. One operator determined root canal length using tactile sense (T), conventional radiography (RAD), tactile sense and conventional radiography (T + RAD), digital radiography (RDIG) and Root ZX electronic apex locator (EAL) methods. Next, the actual length (AL) was visually determined using a K-file from the coronal reference to the apical foramen or apical resorption level. The measurements obtained through each method were compared to the AL using the intraclass correlation coefficient (ICC) with the limits of agreement calculated with Bland and Altman analysis. The measurements were classified as acceptable (+/-1 mm from the AL) or not (>1 mm shorter or longer), and the McNemar test was employed for method comparison.
RESULTS: Differences, limits of agreement and ICCs for each method were respectively EAL = -0.29; -1.02 to 0.44; 0.990; T + RAD = 0.17; -2.18 to 2.51; 0.929; RAD = 0.50; -3.41 to 4.41; 0.818; RDIG = 0.95; -3.76 to 5.65; 0.700; and T = -0.48; -5.59 to 4.64; 0.499. The most accurate and acceptable method was the EAL, followed by the T + RAD. : The EAL method performed best for root canal length determination in primary teeth.

Entities:  

Mesh:

Year:  2010        PMID: 20078703     DOI: 10.1111/j.1365-2591.2009.01667.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  11 in total

1.  Evaluation of the multifrequency electronic apex locator Joypex 5 in primary teeth.

Authors:  E J N L Silva; D R Herrera; E J Souza-Júnior; T P Rosa
Journal:  Eur Arch Paediatr Dent       Date:  2013-07-24

2.  In vitro comparison between apex locators, direct and radiographic techniques for determining the root canal length in primary teeth.

Authors:  L Z Adriano; J C Barasuol; M Cardoso; M Bolan
Journal:  Eur Arch Paediatr Dent       Date:  2019-01-02

3.  Evaluation of the Working Length Determination Accuracy by Cone-beam Computed Tomography in Primary Teeth.

Authors:  John Shibin; Prathima Gs; Suganya M; Nandhakumar S; Sanguida Adimoulame; Kavitha M
Journal:  Int J Clin Pediatr Dent       Date:  2022

4.  Comparison of Accuracy of Apex Locator with Tactile and Conventional Radiographic Method for Working Length Determination in Primary and Permanent Teeth.

Authors:  Khushboo Rathore; Sandeep Tandon; Meenakshi Sharma; Garima Kalia; Tejshree Shekhawat; Yogendra Chundawat
Journal:  Int J Clin Pediatr Dent       Date:  2020 May-Jun

5.  Digital radiography for determination of primary tooth length: in vivo and ex vivo studies.

Authors:  Maria D Basso; Fabiano Jeremias; Rita C L Cordeiro; Lourdes Santos-Pinto
Journal:  ScientificWorldJournal       Date:  2015-02-23

6.  Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth.

Authors:  Zahra Bahrololoomi; Ali Asghar Soleymani; Jalil Modaresi; Mahsa Imanian; Malihe Lotfian
Journal:  J Dent (Tehran)       Date:  2015-04

7.  A smart rotary technique versus conventional pulpectomy for primary teeth: A randomized controlled clinical study.

Authors:  Negar Mokhtari; Alireza-Sarraf Shirazi; Masoumeh Ebrahimi
Journal:  J Clin Exp Dent       Date:  2017-11-01

8.  Use of artificial primary teeth for endodontic laboratory research: experiments related to canal length determination.

Authors:  Anna Carolina V Mello-Moura; Carmela R Bresolin; Cacio Moura-Netto; André Ito; Angela T Araki; José Carlos P Imparato; Fausto M Mendes
Journal:  BMC Oral Health       Date:  2017-11-17       Impact factor: 2.757

9.  A Comparative Evaluation of Accuracy of New-generation Electronic Apex Locator with Conventional Radiography to determine Working Length in Primary Teeth: An in vivo Study.

Authors:  K Vidya Bhat; Prakashchandra Shetty; Latha Anandakrishna
Journal:  Int J Clin Pediatr Dent       Date:  2017-02-27

10.  Endodontic Treatment in Artificial Deciduous Teeth through Manual and Mechanical Instrumentation: A Pilot Study.

Authors:  Fernanda Hecksher; Bruno Vidigal; Patricia Coelho; Diassanam Otoni; Christiano Alvarenga; Eduardo Nunes
Journal:  Int J Clin Pediatr Dent       Date:  2019 Jan-Feb
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.