Influence of LASEK on Schiøtz, Goldmann and dynamic contour Tonometry.

Marco Sales-Sanz1,2, Esther Arranz-Marquez3,4, Carolina Arruabarrena2,5, Miguel A Teus2,5,6.   

Abstract

PURPOSE: Our purpose was to assess the effect of LASEK surgery on ocular rigidity and to compare its effect on intraocular pressure (IOP) readings with Goldmann applanation tonometry (GAT), Schiøtz indentation tonometry (ST) and dynamic contour tonometry (DCT).
METHODS: Prospective, observational, single-masked cohort study. One eye per patient from 31 consecutive subjects who underwent LASEK refractive surgery to correct myopia, as well as from 108 non-operated myopic patients, were included. IOP was measured using GAT, DCT, and ST. The coefficient of ocular rigidity (Ko) was obtained from the regression line of the three readings obtained with each weight of the ST. Linear multiple regression analysis was performed with dummy variables to assess the effect of age, central corneal thickness (CCT), and previous refractive surgery on IOP values.
RESULTS: Age, CCT, and LASEK surgery explained 23% of the IOP readings with GAT, 11% with DCT, and had no significant influence on ST readings. The IOP readings obtained with GAT and DCT, but not with ST, were significantly different between LASEK and control groups. Significant differences in Ko were observed between LASEK (0.014 mmHg/μL ±0.007) and control groups (0.021 mmHg/μL ±0.013) (P = 0.001). Ko values were not related with age or CCT, in either LASEK or control groups.
CONCLUSIONS: ST readings seems to be less affected by LASEK surgery than the other tonometers evaluated. There is a difference in the ocular rigidity between the control and the LASEK eyes that it is not correlated with CCT, so it seems that ST can detect changes in the biomechanical behavior of the LASEK operated corneas.

Entities:  

Keywords:  Dynamic contour tonometry; Goldmann applanation tonometry; LASEK; Ocular rigidity; Schiøtz tonometry

Mesh:

Year:  2017        PMID: 29032414     DOI: 10.1007/s00417-017-3825-4

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  28 in total

1.  Change in intraocular pressure measurement 2 years after myopic laser-assisted subepithelial keratectomy.

Authors:  Gauti Jóhannesson; Per Hallberg; Anders Eklund; Timo Koskela; Christina Lindén
Journal:  J Cataract Refract Surg       Date:  2012-07-11       Impact factor: 3.351

2.  Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis.

Authors:  Jun Liu; Cynthia J Roberts
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

3.  Postoperative changes in intraocular pressure and corneal biomechanical metrics Laser in situ keratomileusis versus laser-assisted subepithelial keratectomy.

Authors:  Mujtaba A Qazi; Jeff P Sanderson; Ashraf M Mahmoud; Eric Y Yoon; Cynthia J Roberts; Jay S Pepose
Journal:  J Cataract Refract Surg       Date:  2009-10       Impact factor: 3.351

Review 4.  Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach.

Authors:  M J Doughty; M L Zaman
Journal:  Surv Ophthalmol       Date:  2000 Mar-Apr       Impact factor: 6.048

Review 5.  Sources of error with use of Goldmann-type tonometers.

Authors:  M M Whitacre; R Stein
Journal:  Surv Ophthalmol       Date:  1993 Jul-Aug       Impact factor: 6.048

6.  Change in intraocular pressure measurements after LASIK the effect of the refractive correction and the lamellar flap.

Authors:  Daniel H Chang; R Doyle Stulting
Journal:  Ophthalmology       Date:  2005-06       Impact factor: 12.079

7.  Ocular rigidity in living human eyes.

Authors:  Ioannis G Pallikaris; George D Kymionis; Harilaos S Ginis; George A Kounis; Miltiadis K Tsilimbaris
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-02       Impact factor: 4.799

8.  In vivo measurement of regional variation in anterior scleral resistance to Schiotz indentation.

Authors:  Hetal Patel; Bernard Gilmartin; Robert P Cubbidge; Nicola S Logan
Journal:  Ophthalmic Physiol Opt       Date:  2011-04-19       Impact factor: 3.117

9.  Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis.

Authors:  Claude Kaufmann; Lucas M Bachmann; Michael A Thiel
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-09       Impact factor: 4.799

10.  Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes.

Authors:  Sunil Shah; Mohammed Laiquzzaman; Rajan Bhojwani; Sanjay Mantry; Ian Cunliffe
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-07       Impact factor: 4.799

View more
  3 in total

1.  Intraocular pressure after LASEK.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-06-20       Impact factor: 3.117

2.  Commentary on "Intraocular Pressure After LASEK".

Authors:  Miguel A Teus; Esther Arranz-Marquez; Marco Sales-Sanz; Carolina Arruabarrena
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-06-20       Impact factor: 3.117

3.  A Critical Assessment of Friedenwald's Technique for Estimating the Coefficient of Rigidity of the Cornea.

Authors:  Larysa Tutchenko; Sudi Patel; Mykhailo Skovron; Olha Horak; Oleksiy Voytsekhivskyy
Journal:  J Ophthalmol       Date:  2022-10-04       Impact factor: 1.974

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.