Sources of error with use of Goldmann-type tonometers.

M M Whitacre1, R Stein.   

Abstract

There are many sources of error in the use of Goldmann-type applanation tonometers. In clinically normal corneas hypofluorescence of the precorneal tear film, accommodation, the Valsalva maneuver and vertical gaze are preventable causes of large tonometric errors. Repeated tonometry may induce a decline in the intraocular pressure (IOP). Variations in the corneal resistance to indentation between eyes cause significant errors. The most significant cause of error in clinically abnormal eyes is corneal epithelial edema, which causes a marked underestimation of IOP. Measurements obtained with Goldmann-type tonometers can be used with confidence to monitor changes in the IOP of an individual, but should not be relied on to determine the absolute manometric pressure within an eye or to compare the IOPs in eyes of different individuals.

Entities:  

Mesh:

Year:  1993        PMID: 8235993     DOI: 10.1016/0039-6257(93)90053-a

Source DB:  PubMed          Journal:  Surv Ophthalmol        ISSN: 0039-6257            Impact factor:   6.048


  153 in total

1.  Cornea plana associated with open-angle glaucoma: a case report.

Authors:  Bilge Ozturk Sahin; Goktug Seymenoglu; Esin F Baser
Journal:  Int Ophthalmol       Date:  2011-12-11       Impact factor: 2.031

2.  The effect of simulated obstructive apnoea on intraocular pressure and pulsatile ocular blood flow in healthy young adults.

Authors:  P O Lundmark; G E Trope; J G Flanagan
Journal:  Br J Ophthalmol       Date:  2003-11       Impact factor: 4.638

3.  Effect of a tight necktie on intraocular pressure.

Authors:  C Teng; R Gurses-Ozden; J M Liebmann; C Tello; R Ritch
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638

4.  Evaluation of the Icare-ONE rebound tonometer as a self-measuring intraocular pressure device in normal subjects.

Authors:  Ioannis Halkiadakis; Aimilianos Stratos; George Stergiopoulos; Eleni Patsea; Sotiris Skouriotis; Panagiotis Mitropoulos; Dimitrios Papaconstantinou; Gerasimos Georgopoulos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-08       Impact factor: 3.117

5.  [Influence of corneal thickness on intraocular pressure measurements following Descemet's stripping automated endothelial keratoplasty (DSAEK)].

Authors:  M K J Klamann; A-K B Maier; J Gonnermann; N Torun; P C Ruokonen
Journal:  Ophthalmologe       Date:  2012-11       Impact factor: 1.059

6.  Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry.

Authors:  Domenico Schiano Lomoriello; Marco Lombardo; Laura Tranchina; Francesco Oddone; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-10-28       Impact factor: 3.117

7.  Corneal hysteresis in post-radial keratotomy primary open-angle glaucoma.

Authors:  Joshua S Hardin; Christopher I Lee; Lydia F Lane; Christian C Hester; R Grant Morshedi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-23       Impact factor: 3.117

8.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

9.  Elevated intraocular pressure in patients with acromegaly.

Authors:  Luciano Quaranta; Ivano Riva; Gherardo Mazziotti; Teresa Porcelli; Irene Floriani; Andreas Katsanos; Andrea Giustina; Anastasios G P Konstas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-10       Impact factor: 3.117

10.  Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study.

Authors:  Mona Pache; Sonja Wilmsmeyer; Sonja Lautebach; Jens Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-09       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.