Literature DB >> 25459883

Mapping B(1)-induced eddy current effects near metallic structures in MR images: a comparison of simulation and experiment.

S Vashaee1, F Goora1, M M Britton2, B Newling1, B J Balcom3.   

Abstract

Magnetic resonance imaging (MRI) in the presence of metallic structures is very common in medical and non-medical fields. Metallic structures cause MRI image distortions by three mechanisms: (1) static field distortion through magnetic susceptibility mismatch, (2) eddy currents induced by switched magnetic field gradients and (3) radio frequency (RF) induced eddy currents. Single point ramped imaging with T1 enhancement (SPRITE) MRI measurements are largely immune to susceptibility and gradient induced eddy current artifacts. As a result, one can isolate the effects of metal objects on the RF field. The RF field affects both the excitation and detection of the magnetic resonance (MR) signal. This is challenging with conventional MRI methods, which cannot readily separate the three effects. RF induced MRI artifacts were investigated experimentally at 2.4 T by analyzing image distortions surrounding two geometrically identical metallic strips of aluminum and lead. The strips were immersed in agar gel doped with contrast agent and imaged employing the conical SPRITE sequence. B1 mapping with pure phase encode SPRITE was employed to measure the B1 field around the strips of metal. The strip geometry was chosen to mimic metal electrodes employed in electrochemistry studies. Simulations are employed to investigate the RF field induced eddy currents in the two metallic strips. The RF simulation results are in good agreement with experimental results. Experimental and simulation results show that the metal has a pronounced effect on the B1 distribution and B1 amplitude in the surrounding space. The electrical conductivity of the metal has a minimal effect.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  B(1) mapping; MRI; Metal artifacts; Pure phase encode; RF eddy current; SPRITE

Year:  2014        PMID: 25459883     DOI: 10.1016/j.jmr.2014.10.016

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  Modeling of active shimming of metallic needles for interventional MRI.

Authors:  Saikat Sengupta
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

2.  Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.

Authors:  Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Kevin M Koch; Scott B Reeder
Journal:  Magn Reson Med       Date:  2017-08-21       Impact factor: 4.668

3.  Real-time 3D imaging of microstructure growth in battery cells using indirect MRI.

Authors:  Andrew J Ilott; Mohaddese Mohammadi; Hee Jung Chang; Clare P Grey; Alexej Jerschow
Journal:  Proc Natl Acad Sci U S A       Date:  2016-09-12       Impact factor: 11.205

4.  Quantitative, In Situ Visualization of Metal-Ion Dissolution and Transport Using (1) H Magnetic Resonance Imaging.

Authors:  Joshua M Bray; Alison J Davenport; Karl S Ryder; Melanie M Britton
Journal:  Angew Chem Int Ed Engl       Date:  2016-06-22       Impact factor: 15.336

Review 5.  Application of Magnetic Resonance Techniques to the In Situ Characterization of Li-Ion Batteries: A Review.

Authors:  Sergey Krachkovskiy; Michel L Trudeau; Karim Zaghib
Journal:  Materials (Basel)       Date:  2020-04-04       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.