Literature DB >> 35014729

Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Philip K Lee1,2, Daehyun Yoon1, Jesse K Sandberg1, Shreyas S Vasanawala1, Brian A Hargreaves1,2,3.   

Abstract

PURPOSE: DWI near metal implants has not been widely explored due to substantial challenges associated with through-slice and in-plane distortions, the increased encoding requirement of different spectral bins, and limited SNR. There is no widely adopted clinical protocol for DWI near metal since the commonly used EPI trajectory fails completely due to distortion from extreme off-resonance ranging from 2 to 20 kHz. We present a sequence that achieves DWI near metal with moderate b-values (400-500 s/mm2 ) and volumetric coverage in clinically feasible scan times. THEORY AND METHODS: Multispectral excitation with Cartesian sampling, view angle tilting, and kz phase encoding reduce in-plane and through-plane off-resonance artifacts, and Carr-Purcell-Meiboom-Gill (CPMG) spin-echo refocusing trains counteract T2* effects. The effect of random phase on the refocusing train is eliminated using a stimulated echo diffusion preparation. Root-flipped Shinnar-Le Roux refocusing pulses permits preparation of a high spectral bandwidth, which improves imaging times by reducing the number of excitations required to cover the desired spectral range. B1 sensitivity is reduced by using an excitation that satisfies the CPMG condition in the preparation. A method for ADC quantification insensitive to background gradients is presented.
RESULTS: Non-linear phase refocusing pulses reduces the peak B1 by 46% which allows RF bandwidth to be doubled. Simulations and phantom experiments show that a non-linear phase CPMG pulse pair reduces B1 sensitivity. Application in vivo demonstrates complementary contrast to conventional multispectral acquisitions and improved visualization compared to DW-EPI.
CONCLUSION: Volumetric and multispectral DW imaging near metal can be achieved with a 3D encoded sequence.
© 2022 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  diffusion preparation; diffusion weighted imaging; distortionless diffusion; multispectral imaging; root-flipped SLR pulses

Mesh:

Year:  2022        PMID: 35014729      PMCID: PMC8979554          DOI: 10.1002/mrm.29153

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  51 in total

1.  Imaging near metal with a MAVRIC-SEMAC hybrid.

Authors:  K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

2.  Analysis and correction of gradient nonlinearity bias in apparent diffusion coefficient measurements.

Authors:  Dariya I Malyarenko; Brian D Ross; Thomas L Chenevert
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

3.  Diffusion-prepared stimulated-echo turbo spin echo (DPsti-TSE): An eddy current-insensitive sequence for three-dimensional high-resolution and undistorted diffusion-weighted imaging.

Authors:  Qinwei Zhang; Bram F Coolen; Maarten J Versluis; Gustav J Strijkers; Aart J Nederveen
Journal:  NMR Biomed       Date:  2017-03-13       Impact factor: 4.044

4.  Analysis of phase error effects in multishot diffusion-prepared turbo spin echo imaging.

Authors:  Anh T Van; Barbara Cervantes; Hendrik Kooijman; Dimitrios C Karampinos
Journal:  Quant Imaging Med Surg       Date:  2017-04

5.  2D multi-spectral imaging for fast MRI near metal.

Authors:  Brian A Hargreaves; Valentina Taviani; Daniel V Litwiller; Daehyun Yoon
Journal:  Magn Reson Med       Date:  2017-04-25       Impact factor: 4.668

6.  Improving MRI's slice selectivity in the presence of strong, metal-derived inhomogeneities.

Authors:  Gil Farkash; Gilad Liberman; Ricardo P Martinho; Lucio Frydman
Journal:  Magn Reson Imaging       Date:  2020-03-13       Impact factor: 2.546

7.  Root-flipped multiband refocusing pulses.

Authors:  Anuj Sharma; Michael Lustig; William A Grissom
Journal:  Magn Reson Med       Date:  2015-02-22       Impact factor: 4.668

8.  Multispectral diffusion-weighted MRI of the instrumented cervical spinal cord: a preliminary study of 5 cases.

Authors:  Kevin M Koch; Sampada Bhave; S Sivaram Kaushik; Andrew S Nencka; Matthew D Budde
Journal:  Eur Spine J       Date:  2019-12-12       Impact factor: 3.134

9.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo.

Authors:  Barbara Cervantes; Anh T Van; Dominik Weidlich; Hendrick Kooijman; Andreas Hock; Ernst J Rummeny; Alexandra Gersing; Jan S Kirschke; Dimitrios C Karampinos
Journal:  Magn Reson Med       Date:  2018-01-29       Impact factor: 4.668

View more
  1 in total

1.  Influence of angioplasty and stenting on intracranial artery stenosis: preliminary results of high-resolution vessel wall imaging evaluation.

Authors:  Chia-Hung Wu; Chih-Ping Chung; Ting-Yi Chen; Kai-Wei Yu; Te-Ming Lin; Wei-An Tai; Chao-Bao Luo; Feng-Chi Chang
Journal:  Eur Radiol       Date:  2022-07-19       Impact factor: 7.034

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.