Wear of double crown systems: electroplated vs. casted female part.

Stefan Bayer1, Dominik Kraus, Ludger Keilig, Lina Gölz, Helmut Stark, Norbert Enkling.   

Abstract

OBJECTIVES: The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings (group E ) with standard telescopic crowns with cast female parts (group C).
MATERIAL AND METHODS: 10 conical crowns were milled for each group of a cast gold alloy. The specimen of group E had a conicity of 2º. The cast secondary crowns of group C had a 0º design. The electroplated coping was established by direct electroforming. An apparatus accomplishing 10,000 wear cycles performed the wear test. The retentive forces and the correlating distance during insertion and separation were measured. The wear test was separated in a start phase, an initial wear phase and the long term wear period. The retention force value and the force-distance integral of the first 0.33 mm of each cycle were calculated.
RESULTS: The retentive forces were significantly higher for group E and the integrals were significantly lower for this group except the integral at cycle 10,000. The changes of retention force and integral did not differ significantly between both groups in all phases. The change of the integrals as well as the integral at the particular cycles showed higher interquartile distances for group C.
CONCLUSIONS: Within the limitations of this study the tested conical crowns showed clinically acceptable retentive properties. The values reached a range comparable to retentive elements tested in recent literature. The values of group C showed higher ranges. The force measured for group E was significantly higher than for group C but the integrals showed an opposite tendency. The results indicate that an exclusive analysis of the force is not sufficient as the integral is not equivalent to the force although it describes the retentive property of the system in a better way than the force over a distance is described. Both systems seem to be suitable for clinical practice.

Entities:  

Mesh:

Year:  2012        PMID: 22858708      PMCID: PMC3881770          DOI: 10.1590/s1678-77572012000300015

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  28 in total

1.  Wear behavior of precision attachments.

Authors:  M G Wichmann; W Kuntze
Journal:  Int J Prosthodont       Date:  1999 Sep-Oct       Impact factor: 1.681

2.  Maximum dislodging forces of implant overdenture stud attachments.

Authors:  Vicki C Petropoulos; Woollcott Smith
Journal:  Int J Oral Maxillofac Implants       Date:  2002 Jul-Aug       Impact factor: 2.804

3.  [Galvano-outer telescope by direct technique].

Authors:  G Diedrichs; P Rosenhain
Journal:  Quintessenz       Date:  1991-01

4.  Telescoping implant prostheses with intraoral luted galvano mesostructures to improve passive fit.

Authors:  Bjoern Greven; Michael Luepke; Soeren Hahn von Dorsche
Journal:  J Prosthet Dent       Date:  2007-09       Impact factor: 3.426

5.  T-bar clasp-retained removable partial denture as an alternative to implant-based prosthetic treatment.

Authors:  Osvaldo Luiz Bezzon; Mariane Gonçalves; Valéria Oliveira Pagnano
Journal:  Braz Dent J       Date:  2008

6.  Investigation of the wear of prefabricated attachments--an in vitro study of retention forces and fitting tolerances.

Authors:  Stefan Bayer; Manfred Grüner; Ludger Keilig; Robert Hültenschmidt; Claudia Nicolay; Christoph Bourauel; Karl-Heinz Utz; Helmut Stark
Journal:  Quintessence Int       Date:  2007-05       Impact factor: 1.677

7.  Surface roughness of different dental materials before and after simulated toothbrushing in vitro.

Authors:  Siegward D Heintze; Monika Forjanic
Journal:  Oper Dent       Date:  2005 Sep-Oct       Impact factor: 2.440

8.  Mandibular two-implant telescopic overdentures.

Authors:  Siegfried M Heckmann; Alexander Schrott; Friedrich Graef; Manfred G Wichmann; Hans-Peter Weber
Journal:  Clin Oral Implants Res       Date:  2004-10       Impact factor: 5.977

9.  Retention force of T-bar clasps for titanium and cobalt-chromium removable partial dentures.

Authors:  Renata Cristina Silveira Rodrigues; Ana Paula Macedo; Erica Miranda de Torres; Maria da Glória Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  Braz Dent J       Date:  2008

10.  Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment.

Authors:  Rudys Rodolfo de Jesus Tavarez; Wellington Cardoso Bonachela; Anuar Antônio Xible
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

View more
  4 in total

1.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

2.  Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial.

Authors:  Thomas Stober; Justo Lorenzo Bermejo; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Wolfgang Bömicke
Journal:  Clin Oral Investig       Date:  2014-10-11       Impact factor: 3.573

3.  Retention Load Values of Telescopic Crowns Made of Y-TZP and CoCr with Y-TZP Secondary Crowns: Impact of Different Taper Angles.

Authors:  Susanne Merk; Christina Wagner; Veronika Stock; Patrick R Schmidlin; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-05-11       Impact factor: 3.623

4.  PEEK Primary Crowns with Cobalt-Chromium, Zirconia and Galvanic Secondary Crowns with Different Tapers-A Comparison of Retention Forces.

Authors:  Veronika Stock; Patrick R Schmidlin; Susanne Merk; Christina Wagner; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-03-10       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.