Literature DB >> 26676273

The Esthetic Effect of Veneered Zirconia Abutments for Single-Tooth Implant Reconstructions: A Randomized Controlled Clinical Trial.

Daniel S Thoma1, Francine Brandenberg1, Vincent Fehmer2, Nathalie Knechtle3, Christoph Hf Hämmerle1, Irena Sailer2.   

Abstract

PURPOSE: The purposes of this study were to test whether or not veneering of the submucosal part of zirconia abutments can positively influence the esthetic outcome compared with nonveneered zirconia abutments; to evaluate the influence of the mucosal thickness on the esthetic outcomes of the veneered and nonveneered abutments; and to evaluate the thickness of the peri-implant mucosa compared with the thickness of the gingiva of contralateral tooth sites.
MATERIALS AND METHODS: Forty-four single-tooth implants in 44 patients were randomly restored with either cemented (CR) or screw-retained (SR) reconstructions based on white zirconia abutments (CR-W, SR-W) or pink-veneered zirconia abutments (CR-P, SR-P). Esthetic outcome measurements were performed based on a spectrophotometric evaluation of the peri-implant mucosal color. In addition, the thickness of the mucosa was measured. A two-way analysis of variance was conducted to test the effect of veneering (pink vs white) and mucosa thickness (<2 mm vs ≥2 mm) on the calculated color difference ΔE for pooled data of CR and SR reconstructions (p < .05).
RESULTS: Analyses grouping the sites according to veneering of the abutments and mucosal thickness demonstrated less discoloration for sites with a veneered abutment irrespective of the mucosal thickness: ΔE 4.50 ± 1.93 (<2 mm) and ΔE 6.88 ± 2.45 (≥2 mm); CR-P, SR-P) compared with sites without veneering ΔE 9.72 ± 3.82 (<2 mm; CR-W, SR-W) and ΔE 8.31 ± 2.98 (≥2 mm). The differences between veneered and nonveneered abutments were significant (p = .032).
CONCLUSIONS: Veneering of zirconia abutments with pink veneering ceramic positively influenced the peri-implant mucosal color.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  ceramic abutments; crowns; dental abutments; dental implants; zirconia

Mesh:

Substances:

Year:  2015        PMID: 26676273     DOI: 10.1111/cid.12388

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

1.  Retention Load Values of Telescopic Crowns Made of Y-TZP and CoCr with Y-TZP Secondary Crowns: Impact of Different Taper Angles.

Authors:  Susanne Merk; Christina Wagner; Veronika Stock; Patrick R Schmidlin; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-05-11       Impact factor: 3.623

2.  Five-year randomized controlled clinical study comparing cemented and screw-retained zirconia-based implant-supported single crowns.

Authors:  Riccardo D Kraus; Catharina Espuelas; Christoph H F Hämmerle; Ronald E Jung; Irena Sailer; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2022-03-03       Impact factor: 5.021

3.  Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Part II: Soft Tissues.

Authors:  Rubén Agustín-Panadero; Naia Bustamante-Hernández; Carlos Labaig-Rueda; Antonio Fons-Font; Lucía Fernández-Estevan; María Fernanda Solá-Ruíz
Journal:  J Clin Med       Date:  2019-12-16       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.