Literature DB >> 28618819

Evaluation of uncertainty for regularized deconvolution: A case study in hydrophone measurements.

S Eichstädt1, V Wilkens1.   

Abstract

An estimation of the measurand in dynamic metrology usually requires a deconvolution based on a dynamic calibration of the measuring system. Since deconvolution is, mathematically speaking, an ill-posed inverse problem, some kind of regularization is required to render the problem stable and obtain usable results. Many approaches to regularized deconvolution exist in the literature, but the corresponding evaluation of measurement uncertainties is, in general, an unsolved issue. In particular, the uncertainty contribution of the regularization itself is a topic of great importance, because it has a significant impact on the estimation result. Here, a versatile approach is proposed to express prior knowledge about the measurand based on a flexible, low-dimensional modeling of an upper bound on the magnitude spectrum of the measurand. This upper bound allows the derivation of an uncertainty associated with the regularization method in line with the guidelines in metrology. As a case study for the proposed method, hydrophone measurements in medical ultrasound with an acoustic working frequency of up to 7.5 MHz are considered, but the approach is applicable for all kinds of estimation methods in dynamic metrology, where regularization is required and which can be expressed as a multiplication in the frequency domain.

Entities:  

Year:  2017        PMID: 28618819     DOI: 10.1121/1.4983827

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  10 in total

1.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part II: Experimental Validation of Spatial Averaging Model.

Authors:  Keith A Wear; Yunbo Liu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

2.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

3.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

4.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part I: Theory and Impact on Diagnostic Safety Indexes.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

5.  Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-24       Impact factor: 2.725

6.  Spatiotemporal Deconvolution of Hydrophone Response for Linear and Nonlinear Beams-Part I: Theory, Spatial-Averaging Correction Formulas, and Criteria for Sensitive Element Size.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

7.  Spatiotemporal Deconvolution of Hydrophone Response for Linear and Nonlinear Beams-Part II: Experimental Validation.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

8.  Directivity and Frequency-Dependent Effective Sensitive Element Size of a Reflectance-Based Fiber-Optic Hydrophone: Predictions From Theoretical Models Compared With Measurements.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

9.  Pressure Pulse Distortion by Needle and Fiber-Optic Hydrophones due to Nonuniform Sensitivity.

Authors:  Keith A Wear; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-02       Impact factor: 2.725

10.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Needle Hydrophones: Predictions From Four Theoretical Forms Compared With Measurements.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07-13       Impact factor: 2.725

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.