| Literature DB >> 28533802 |
Ritu Raj Upreti1, Ashwini Budrukkar2, Tabassum Wadasadawala3, Shagun Misra2, Lavanya Gurram2, Rima Pathak2, Deepak D Deshpande1.
Abstract
PURPOSE: To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy.Entities:
Keywords: APBI; breast cancer; cavity visualization; interobserver variation
Year: 2017 PMID: 28533802 PMCID: PMC5437076 DOI: 10.5114/jcb.2017.66027
Source DB: PubMed Journal: J Contemp Brachytherapy ISSN: 2081-2841
Fig. 1The cavity visualization index. A) Cavity is well visualized with distinction from breast/muscle tissues. B) Cavity is visualized but not clearly distinguishable with either breast or muscle tissue. C) Cavity is visualized but not clearly distinguishable with both breast and muscle tissue. D) All parameters are not satisfactory
Comparison of clinical target volumes (CTV) among all observers
| Pairwise comparison | Median difference in CTV volume (cm3) | |
|---|---|---|
| ∆21 (CTV2-CTV1) | 9.1 | 0.019 |
| ∆31 (CTV3-CTV1) | 30.0 | 0.000 |
| ∆41 (CTV4-CTV1) | 22.0 | 0.001 |
| ∆15 (CTV1-CTV5) | 6.9 | 0.970 |
| ∆32 (CTV3-CTV2) | 15.0 | 0.001 |
| ∆42 (CTV4-CTV2) | 12.9 | 0.021 |
| ∆25 (CTV2-CTV5) | 5.9 | 0.015 |
| ∆34 (CTV3-CTV4) | 2.1 | 0.218 |
| ∆35 (CTV3-CTV5) | 25.7 | 0.000 |
| ∆45 (CTV4-CTV5) | 16.9 | 0.001 |
For pairwise comparison data was arrange to keep median difference positive
Wilcoxon signed-rank test
CTV – clinical target volume, ∆– difference in the volume
Lumpectomy cavity and clinical target volume variability
| Lumpectomy cavity (LC) | Clinical target volume (CTV) | |||||
|---|---|---|---|---|---|---|
| Mean | Median | SD | Mean | Median | SD | |
| Volume (cm3) | 75.8 | 68.0 | 30.9 | 159.8 | 146.6 | 58.8 |
| CIcommon | 0.54 | 0.56 | 0.09 | 0.58 | 0.58 | 0.08 |
| CIgen | 0.74 | 0.75 | 0.06 | 0.76 | 0.78 | 0.05 |
| COM shift (cm) | 0.27 | 0.26 | 0.10 | 0.34 | 0.33 | 0.13 |
| Vmax/Vmin | 1.32 | 1.26 | 0.19 | 1.36 | 1.34 | 0.22 |
SD – standard deviation, CIcommon – conformity index among all observers, CIgen – generalized conformity index for all observers, COM shift – shift in the center of mass of the volume, Vmax – maximum volume among observers, Vmin – minimum volume among observers
Cavity visualization index (CVI) and variability of lumpectomy cavity and clinical target volumes with median value and range
| CVI | 1 | 2 | 3 | ρ value |
|---|---|---|---|---|
| 4 | 10 | 6 | ||
| COM shift of LC (cm) | 0.41 (0.29-0.46) | 0.26 (0.19-0.52) | 0.18 (0.12-0.26) | 0.004 |
| COM shift of CTV (cm) | 0.46 (0.37-0.62) | 0.35 (0.2-0.61) | 0.26 (0.17-0.32) | 0.019 |
| CIcommon LC | 0.48 (0.33-0.49) | 0.56 (0.40-0.66) | 0.61 (0.53-0.65) | 0.01 |
| CIcommon CTV | 0.50 (0.39-0.56) | 0.59 (0.45-0.70) | 0.65 (0.51-0.68) | 0.02 |
| CIgen LC | 0.69 (0.59-0.69) | 0.75 (0.64-0.81) | 0.78 (0.74-0.82) | 0.004 |
| CIgen CTV | 0.72 (0.65-0.75) | 0.78 (0.69-0.83) | 0.81 (0.73-0.83) | 0.018 |
| Vmax/Vmin (LC) | 1.42 (1.36-1.75) | 1.26 (1.10-1.73) | 1.19 (1.07-1.29) | 0.029 |
| Vmax/Vmin (CTV) | 1.57 (1.44-2.02) | 1.29 (1.14-1.68) | 1.20 (1.15-1.50) | 0.008 |
One-way ANOVA test
LC – lumpectomy cavity, CTV – clinical target volume, CIcommon – conformity index among all observers, CIgen – generalized conformity index for all observers, Vmax – maximum volume among observers, Vmin – minimum volume among observers
Impact of interobserver variation on active source positions
| Variations in dwell positions | Variation in cm | No of catheters | % of total catheters |
|---|---|---|---|
| 0 | 0 | 92 | 29.8 |
| 1 | 0.5 | 92 | 29.8 |
| 2 | 1.0 | 54 | 17.5 |
| 3 | 1.5 | 24 | 7.8 |
| 4 | 2.0 | 14 | 4.5 |
| 5 | 2.5 | 4 | 1.3 |
| 10 | 5.0 | 21 | 6.8 |
| 15 | 7.5 | 8 | 2.5 |
Impact of interobserver variation on dosimetric parameters
| Min | Max | Median | Mean | SD | |
|---|---|---|---|---|---|
| V100% (cm3) | 74.4 | 229.6 | 134.2 | 135.1 | 43.7 |
| CIcommon of V100% | 0.52 | 0.90 | 0.76 | 0.75 | 0.11 |
| Max/Min of V100% | 1.03 | 1.56 | 1.15 | 1.18 | 0.13 |
| TRAK (cGy at 1 m) | 0.18 | 0.32 | 0.24 | 0.24 | 0.04 |
| Max/Min of TRAK | 1.03 | 1.35 | 1.09 | 1.11 | 0.07 |
V100% – volume of breast in cm3 receiving prescription isodose, Max/Min of V100% – ratio of maximum and minimum volume of breast volume receiving prescription isodose among all observers, TRAK – total reference air kerma in cGy at 1 meter