Literature DB >> 17707265

Target volume delineation for partial breast radiotherapy planning: clinical characteristics associated with low interobserver concordance.

Ross P Petersen1, Pauline T Truong, Hosam A Kader, Eric Berthelet, Junella C Lee, Michelle L Hilts, Adam S Kader, Wayne A Beckham, Ivo A Olivotto.   

Abstract

PURPOSE: To examine variability in target volume delineation for partial breast radiotherapy planning and evaluate characteristics associated with low interobserver concordance. METHODS AND MATERIALS: Thirty patients who underwent planning CT for adjuvant breast radiotherapy formed the study cohort. Using a standardized scale to score seroma clarity and consensus contouring guidelines, three radiation oncologists independently graded seroma clarity and delineated seroma volumes for each case. Seroma geometric center coordinates, maximum diameters in three axes, and volumes were recorded. Conformity index (CI), the ratio of overlapping volume and encompassing delineated volume, was calculated for each case. Cases with CI </=0.50 were analyzed to identify features associated with low concordance.
RESULTS: The median time from surgery to CT was 42.5 days. For geometric center coordinates, variations from the mean were 0.5-1.1 mm and standard deviations (SDs) were 0.5-1.8 mm. For maximum seroma dimensions, variations from the mean and SDs were predominantly <5 mm, with the largest SDs observed in the medial-lateral axis. The mean CI was 0.61 (range, 0.27-0.84). Five cases had CI </=0.50. Conformity index was significantly associated with seroma clarity (p < 0.001) and seroma volume (p < 0.002). Features associated with reduced concordance included tissue stranding from the surgical cavity, proximity to muscle, dense breast parenchyma, and benign calcifications that may be mistaken for surgical clips.
CONCLUSION: Variability in seroma contouring occurred in three dimensions, with the largest variations in the medial-lateral axis. Awareness of clinical features associated with reduced concordance may be applied toward training staff and refining contouring guidelines for partial breast radiotherapy trials.

Entities:  

Mesh:

Year:  2007        PMID: 17707265     DOI: 10.1016/j.ijrobp.2007.01.070

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  33 in total

1.  Critical discussion of evaluation parameters for inter-observer variability in target definition for radiation therapy.

Authors:  I Fotina; C Lütgendorf-Caucig; M Stock; R Pötter; D Georg
Journal:  Strahlenther Onkol       Date:  2012-01-27       Impact factor: 3.621

2.  Interobserver variability in target volume delineation in postoperative radiochemotherapy for gastric cancer. A pilot prospective study.

Authors:  Cristina Moretones; David León; Arturo Navarro; Olalla Santacruz; Ana María Boladeras; Miquel Macià; María Cambray; Valentí Navarro; Ignasi Modolell; Ferran Guedea
Journal:  Clin Transl Oncol       Date:  2012-02       Impact factor: 3.405

3.  Displacement of the lumpectomy cavity defined by surgical clips and seroma based on 4D-CT scan for external-beam partial breast irradiation after breast-conserving surgery: a comparative study.

Authors:  Y Ding; J Li; W Wang; S Wang; T Fan; M Xu; Q Shao; Z Ma
Journal:  Br J Radiol       Date:  2013-08-30       Impact factor: 3.039

4.  A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes.

Authors:  R Jena; N F Kirkby; K E Burton; A C F Hoole; L T Tan; N G Burnet
Journal:  Br J Radiol       Date:  2009-07-20       Impact factor: 3.039

Review 5.  Improving radiotherapy quality assurance in clinical trials: assessment of target volume delineation of the pre-accrual benchmark case.

Authors:  S Gwynne; E Spezi; D Sebag-Montefiore; S Mukherjee; E Miles; J Conibear; J Staffurth
Journal:  Br J Radiol       Date:  2013-02-07       Impact factor: 3.039

Review 6.  Interobserver variation in parotid gland delineation: a study of its impact on intensity-modulated radiotherapy solutions with a systematic review of the literature.

Authors:  S W Loo; W M C Martin; P Smith; S Cherian; T W Roques
Journal:  Br J Radiol       Date:  2012-08       Impact factor: 3.039

7.  Reliability and accuracy assessment of Radiation Therapy Oncology Group-endorsed guidelines for brachial plexus contouring.

Authors:  Joris Van de Velde; Tom Vercauteren; Werner De Gersem; Johan Wouters; Katrien Vandecasteele; Philippe Vuye; Frank Vanpachtenbeke; Katharina D'Herde; Ingrid Kerckaert; Wilfried De Neve; Tom Van Hoof
Journal:  Strahlenther Onkol       Date:  2014-04-09       Impact factor: 3.621

8.  Delineation of the larynx as organ at risk in radiotherapy: a contouring course within "Rete Oncologica Piemonte-Valle d'Aosta" network to reduce inter- and intraobserver variability.

Authors:  Domenico Cante; Edoardo Petrucci; Cristina Piva; Valeria Casanova Borca; Piera Sciacero; Maurizio Bertodatto; Caterina Marta; Pierfrancesco Franco; Monica Viale; Giovanni La Valle; Maria Rosa La Porta; Oscar Bertetto
Journal:  Radiol Med       Date:  2016-07-15       Impact factor: 3.469

Review 9.  Accelerated Partial Breast Irradiation (APBI): A review of available techniques.

Authors:  Christopher F Njeh; Mark W Saunders; Christian M Langton
Journal:  Radiat Oncol       Date:  2010-10-04       Impact factor: 3.481

10.  3D-conformal accelerated partial breast irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity.

Authors:  Maia Dzhugashvili; Elodie Tournay; Charlotte Pichenot; Ariane Dunant; Eduardo Pessoa; Adel Khallel; Sébastien Gouy; Catherine Uzan; Jean-Rémy Garbay; Françoise Rimareix; Marc Spielmann; Philippe Vielh; Hugo Marsiglia; Céline Bourgier
Journal:  Radiat Oncol       Date:  2009-12-31       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.