M C Smitt1, R L Birdwell, D R Goffinet. 1. Department of Radiation Oncology, Stanford Hospital, Stanford University Medical Center, 300 Pasteur Dr, Stanford, CA 94305, USA. melanies@reyes.stanford.edu
Abstract
PURPOSE: To compare computed tomography (CT) with ultrasonography (US) for depiction of the biopsy cavity. MATERIALS AND METHODS: Thirty-two consecutive patients who underwent radiation therapy following lumpectomy with a planned electron boost were examined. At the time of simulation for whole-breast radiation therapy, all patients underwent planning CT (CT 1) at 3-mm section intervals. At the time of electron boost simulation, US was performed to define the biopsy cavity. In 17 cases, a second CT examination (CT 2) was performed at the time of electron boost simulation. CT and US studies were reviewed jointly and assigned a cavity visualization score (CVS) of 1 (cavity not visualized) to 5 (all cavity margins clearly defined). RESULTS: The median CVS at CT 1 was 5; at CT 2, 4; and at US, 4. For patients who underwent all three studies, the median CVS at CT 1 was 5; at CT 2, 4; and at US, 4. Factors related to CVS at CT 1 were homogeneous versus heterogeneous appearance (score, 5 vs 4), surgery-to-CT interval (< or =30 days, 5; 31-60 days, 4; >60 days, 4), and cavity size (>15 cm(3), 5; <15 cm(3), 4). In all cases, cavity volume decreased somewhat during the CT 1-to-CT 2 interval. CONCLUSION: CT performed at the time of whole-breast simulation can be used to plan electron boost fields, with cavity visualization similar to that at US.
PURPOSE: To compare computed tomography (CT) with ultrasonography (US) for depiction of the biopsy cavity. MATERIALS AND METHODS: Thirty-two consecutive patients who underwent radiation therapy following lumpectomy with a planned electron boost were examined. At the time of simulation for whole-breast radiation therapy, all patients underwent planning CT (CT 1) at 3-mm section intervals. At the time of electron boost simulation, US was performed to define the biopsy cavity. In 17 cases, a second CT examination (CT 2) was performed at the time of electron boost simulation. CT and US studies were reviewed jointly and assigned a cavity visualization score (CVS) of 1 (cavity not visualized) to 5 (all cavity margins clearly defined). RESULTS: The median CVS at CT 1 was 5; at CT 2, 4; and at US, 4. For patients who underwent all three studies, the median CVS at CT 1 was 5; at CT 2, 4; and at US, 4. Factors related to CVS at CT 1 were homogeneous versus heterogeneous appearance (score, 5 vs 4), surgery-to-CT interval (< or =30 days, 5; 31-60 days, 4; >60 days, 4), and cavity size (>15 cm(3), 5; <15 cm(3), 4). In all cases, cavity volume decreased somewhat during the CT 1-to-CT 2 interval. CONCLUSION: CT performed at the time of whole-breast simulation can be used to plan electron boost fields, with cavity visualization similar to that at US.
Authors: I Chitapanarux; M Muttarak; W Na-Chiangmai; H Trakultivakorn; A Somwangprasert; P Kamnerdsupaphon; E Tharavichitkul; V Sukthomya; V Lorvidhaya; A Watcharawipha Journal: Biomed Imaging Interv J Date: 2009-07-01
Authors: Mariska D DEN Hartogh; Marielle E P Philippens; Iris E VAN Dam; Catharina E Kleynen; Robbert J H A Tersteeg; Alexis N T J Kotte; Marco VAN Vulpen; Bram VAN Asselen; Desirée H J G VAN DEN Bongard Journal: Oncol Lett Date: 2015-09-14 Impact factor: 2.967