Literature DB >> 11274557

Breast electron boost planning: comparison of CT and US.

M C Smitt1, R L Birdwell, D R Goffinet.   

Abstract

PURPOSE: To compare computed tomography (CT) with ultrasonography (US) for depiction of the biopsy cavity.
MATERIALS AND METHODS: Thirty-two consecutive patients who underwent radiation therapy following lumpectomy with a planned electron boost were examined. At the time of simulation for whole-breast radiation therapy, all patients underwent planning CT (CT 1) at 3-mm section intervals. At the time of electron boost simulation, US was performed to define the biopsy cavity. In 17 cases, a second CT examination (CT 2) was performed at the time of electron boost simulation. CT and US studies were reviewed jointly and assigned a cavity visualization score (CVS) of 1 (cavity not visualized) to 5 (all cavity margins clearly defined).
RESULTS: The median CVS at CT 1 was 5; at CT 2, 4; and at US, 4. For patients who underwent all three studies, the median CVS at CT 1 was 5; at CT 2, 4; and at US, 4. Factors related to CVS at CT 1 were homogeneous versus heterogeneous appearance (score, 5 vs 4), surgery-to-CT interval (< or =30 days, 5; 31-60 days, 4; >60 days, 4), and cavity size (>15 cm(3), 5; <15 cm(3), 4). In all cases, cavity volume decreased somewhat during the CT 1-to-CT 2 interval.
CONCLUSION: CT performed at the time of whole-breast simulation can be used to plan electron boost fields, with cavity visualization similar to that at US.

Entities:  

Mesh:

Year:  2001        PMID: 11274557     DOI: 10.1148/radiology.219.1.r01ap34203

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

1.  3-D conformal photon boost in the treatment of early stage breast cancer: four year follow up results.

Authors:  Arpad Kovacs; Ferenc Lakosi; Gabor Liposits; Gabor Toller; Janaki Hadjiev; Csaba Vandulek; Norbert Walter; Csaba Glavak; Gergely Antal; Akos Horvath; Imre Repa; Peter Bogner
Journal:  Pathol Oncol Res       Date:  2010-04-11       Impact factor: 3.201

2.  Comparison of photon with electron boost in treatment of early stage breast cancer.

Authors:  Arpad Kovacs; Janaki Hadjiev; Ferenc Lakosi; Csaba Glavak; Gergely Antal; Peter Bogner; Akos Horvath; Imre Repa
Journal:  Pathol Oncol Res       Date:  2008-03-15       Impact factor: 3.201

3.  Post-chemotherapy target volumes are safe as boost volume for intact breast radiotherapy in locally advanced breast cancer.

Authors:  Sushma Agrawal; Waseem Raza; Punita Lal; K J Maria Das; Gaurav Agarwal
Journal:  Rep Pract Oncol Radiother       Date:  2020-02-21

4.  Discrepancies in determining electron energy for lumpectomy boost treatment.

Authors:  Aime M Gloi; Robert Buchanan
Journal:  J Med Phys       Date:  2012-07

5.  Can radiographic plain film be used to determine the depth of the tumour bed in the absence of surgical clips for breast boost planning.

Authors:  I Chitapanarux; M Muttarak; W Na-Chiangmai; H Trakultivakorn; A Somwangprasert; P Kamnerdsupaphon; E Tharavichitkul; V Sukthomya; V Lorvidhaya; A Watcharawipha
Journal:  Biomed Imaging Interv J       Date:  2009-07-01

6.  Post-lumpectomy CT-guided tumor bed delineation for breast boost and partial breast irradiation: Can additional pre- and postoperative imaging reduce interobserver variability?

Authors:  Mariska D DEN Hartogh; Marielle E P Philippens; Iris E VAN Dam; Catharina E Kleynen; Robbert J H A Tersteeg; Alexis N T J Kotte; Marco VAN Vulpen; Bram VAN Asselen; Desirée H J G VAN DEN Bongard
Journal:  Oncol Lett       Date:  2015-09-14       Impact factor: 2.967

7.  3D-conformal accelerated partial breast irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity.

Authors:  Maia Dzhugashvili; Elodie Tournay; Charlotte Pichenot; Ariane Dunant; Eduardo Pessoa; Adel Khallel; Sébastien Gouy; Catherine Uzan; Jean-Rémy Garbay; Françoise Rimareix; Marc Spielmann; Philippe Vielh; Hugo Marsiglia; Céline Bourgier
Journal:  Radiat Oncol       Date:  2009-12-31       Impact factor: 3.481

8.  The Impact of Different Simulation Modalities on Target Volume Delineation in Breast-Conserving Radiotherapy.

Authors:  Meng Jin; Xia Liu; Jiabin Ma; Xiansong Sun; Hongnan Zhen; Jing Shen; Zhikai Liu; Xin Lian; Zheng Miao; Ke Hu; Xiaorong Hou; Fuquan Zhang
Journal:  Cancer Manag Res       Date:  2021-07-12       Impact factor: 3.989

9.  Inter-observer variations of the tumor bed delineation for patients after breast conserving surgery in preoperative magnetic resonance and computed tomography scan fusion.

Authors:  Jie Jiang; Jinhu Chen; Wanhu Li; Yongqing Li; Yiru Chen; Zicheng Zhang; Chengxin Liu; Dan Han; Hongfu Sun; Baosheng Li; Wei Huang
Journal:  BMC Cancer       Date:  2021-07-20       Impact factor: 4.430

10.  Target volume delineation in breast conserving radiotherapy: are co-registered CT and MR images of added value?

Authors:  Mirjam Mast; Emile Coerkamp; Mark Heijenbrok; Astrid Scholten; Wim Jansen; Erik Kouwenhoven; Jasper Nijkamp; Stephanie de Waard; Anna Petoukhova; Henk Struikmans
Journal:  Radiat Oncol       Date:  2014-02-26       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.