CT-guided multi-catheter insertion technique for partial breast brachytherapy: reliable target coverage and dose homogeneity.

Laurie W Cuttino1, Dorin Todor, Douglas W Arthur.   

Abstract

PURPOSE: To evaluate the feasibility and dosimetric reliability of a CT-guided method of catheter insertion for accelerated partial breast brachytherapy (APBB).
MATERIALS AND METHODS: From 1995 to 2002, 77 patients were treated with APBB using a multi-catheter low-dose-rate or high-dose-rate approach. Within that timeframe, 29 patients with early stage invasive breast cancer were treated with high-dose-rate partial breast brachytherapy and had CT scans of the brachytherapy implant available for analysis. Initially, catheter insertion was accomplished in the operating room at the time of lumpectomy using standard free-hand insertion techniques under fluoroscopic guidance and subsequent orthogonal film dosimetry. To improve the efficiency and quality of the technique, the procedure was moved to the departmental CT-simulation suite where the catheters were placed with CT guidance. Basic guidelines of needle insertion and implant construction were followed to assure appropriate intercatheter and interplanar spacing that allowed optimal dosimetric coverage of the target volume. Target volumes were delineated and a treatment plan generated using a 3D planning system (Varian Brachyvision). PTV 1 cm was defined as the lumpectomy cavity plus 1 cm and PTV 2 cm as the lumpectomy cavity plus 2 cm. Target coverage goals were set as delivery of 100% of the prescribed dose to >95% of PTV 1 cm and >90% of the dose to >90% of PTV 2 cm. Dose homogeneity index (DHI) was defined as (V150%-V100%/V100%) with a goal of achieving >0.75. Fifteen patients were treated using the initial method and 14 patients using the CT-guided technique. Targets were retrospectively entered in the initial group and dose volume histogram analysis completed on all patients. The ability of each technique to achieve the target coverage and homogeneity goals was compared.
RESULTS: With the change from traditional techniques to a CT-guided technique, the percentage of patients satisfying all dosimetric goals increased from 42% to 93%. Mean dose coverage (defined as the percentage of PTV 2 cm receiving 90% of the prescribed dose) increased from 89% to 95% (p=0.007) and the mean DHI increased from 0.77 to 0.82 with the new technique (p < 0.005).
CONCLUSIONS: Reproducible target coverage and dose homogeneity were achieved with CT-guided catheter insertion and 3D planning software. Catheters can be optimally placed with intraoperative CT evaluation and 3D planning software allows improved implant visualization resulting in optimized dosimetry. Improvements in target coverage and DHI may translate into optimized local control and improved cosmesis with a corresponding reduction in the risk of complications.

Entities:  

Mesh:

Year:  2005        PMID: 15737901     DOI: 10.1016/j.brachy.2004.11.002

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  14 in total

Review 1.  Update on accelerated partial-breast irradiation.

Authors:  Alphonse G Taghian; Abram Recht
Journal:  Curr Oncol Rep       Date:  2006-01       Impact factor: 5.075

Review 2.  Current modalities of accelerated partial breast irradiation.

Authors:  John A Cox; Todd A Swanson
Journal:  Nat Rev Clin Oncol       Date:  2013-04-30       Impact factor: 66.675

3.  Accelerated partial breast irradiation with low-dose-rate interstitial implant brachytherapy after wide local excision: 12-year outcomes from a prospective trial.

Authors:  Jona A Hattangadi; Simon N Powell; Shannon M MacDonald; Thomas Mauceri; Marek Ancukiewicz; Phoebe Freer; Brian Lawenda; Mohamed A Alm El-Din; Michele A Gadd; Barbara L Smith; Alphonse G Taghian
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-11-16       Impact factor: 7.038

Review 4.  Current status and perspectives of brachytherapy for breast cancer.

Authors:  Csaba Polgár; Tibor Major
Journal:  Int J Clin Oncol       Date:  2009-02-20       Impact factor: 3.402

5.  Evaluation of radiograph-based interstitial implant dosimetry on computed tomography images using dose volume indices for head and neck cancer.

Authors:  Ritu Raj Upreti; S Dayananda; R L Bhalawat; Girish N Bedre; D D Deshpande
Journal:  J Med Phys       Date:  2007-04

Review 6.  Accelerated partial breast irradiation: the case for current use.

Authors:  Martin E Keisch
Journal:  Breast Cancer Res       Date:  2005-04-05       Impact factor: 6.466

Review 7.  Accelerated partial breast irradiation with brachytherapy: patient selection and technique considerations.

Authors:  Daniel M Trifiletti; Kara D Romano; Shayna L Showalter; Kelli A Reardon; Bruce Libby; Timothy N Showalter
Journal:  Breast Cancer (Dove Med Press)       Date:  2015-07-29

Review 8.  Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM.

Authors:  Christian Kirisits; Mark J Rivard; Dimos Baltas; Facundo Ballester; Marisol De Brabandere; Rob van der Laarse; Yury Niatsetski; Panagiotis Papagiannis; Taran Paulsen Hellebust; Jose Perez-Calatayud; Kari Tanderup; Jack L M Venselaar; Frank-André Siebert
Journal:  Radiother Oncol       Date:  2013-11-30       Impact factor: 6.280

9.  The importance of the implant quality in APBI - Gliwice experience. Dosimetric evaluation.

Authors:  Agnieszka Cholewka; Marta Szlag; Brygida Białas; Sylwia Kellas-Ślęczka; Krzysztof Slosarek
Journal:  J Contemp Brachytherapy       Date:  2013-12-05

10.  Multi-catheter interstitial brachytherapy for partial breast irradiation: an audit of implant quality based on dosimetric evaluation comparing intra-operative versus post-operative placement.

Authors:  Lavanya Gurram; Tabassum Wadasadawala; Kishor Joshi; Reena Phurailatpam; Siji Paul; Rajiv Sarin
Journal:  J Contemp Brachytherapy       Date:  2016-04-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.