Literature DB >> 19384002

Measuring the similarity of target volume delineations independent of the number of observers.

Erik Kouwenhoven1, Marina Giezen, Henk Struikmans.   

Abstract

The variability of target delineations is a topic of interest in radiotherapy. The similarity of delineations is often quantified by use of a conformity index (CI) defined as the ratio of common to encompassing volume. Several forms of CI are in use, but no consensus exists on how to calculate the CI for more than two delineations. This study proposes a generalization of the CI applicable to any number of delineations. The generalization of the CI was developed, unbiased with respect to the number of delineations. Numerical values were calculated for clinical and theoretical cases, and differences with other forms of CI were considered. A simple expression could be derived, applicable to any number of delineations, and is equivalent to the known CI for two delineations. The use of this index is advised, although another frequently used index obtained from averaging the CI between all possible pairs of delineations results in minor differences. The use of the third generalization for the CI which is based upon the volume common to all delineations shows a clear dependence upon the number of delineations and is discouraged.

Mesh:

Year:  2009        PMID: 19384002     DOI: 10.1088/0031-9155/54/9/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  42 in total

1.  Critical discussion of evaluation parameters for inter-observer variability in target definition for radiation therapy.

Authors:  I Fotina; C Lütgendorf-Caucig; M Stock; R Pötter; D Georg
Journal:  Strahlenther Onkol       Date:  2012-01-27       Impact factor: 3.621

2.  Assessment of accuracy and efficiency of atlas-based autosegmentation for prostate radiotherapy in a variety of clinical conditions.

Authors:  I Simmat; P Georg; D Georg; W Birkfellner; G Goldner; M Stock
Journal:  Strahlenther Onkol       Date:  2012-06-07       Impact factor: 3.621

3.  Prediction of micropapillary and solid pattern in lung adenocarcinoma using radiomic values extracted from near-pure histopathological subtypes.

Authors:  Li-Wei Chen; Shun-Mao Yang; Hao-Jen Wang; Yi-Chang Chen; Mong-Wei Lin; Min-Shu Hsieh; Hsiang-Lin Song; Huan-Jang Ko; Chung-Ming Chen; Yeun-Chung Chang
Journal:  Eur Radiol       Date:  2021-01-03       Impact factor: 5.315

4.  Interobserver variation in clinical target volume and organs at risk segmentation in post-parotidectomy radiotherapy: can segmentation protocols help?

Authors:  M Mukesh; R Benson; R Jena; A Hoole; T Roques; C Scrase; C Martin; G A Whitfield; J Gemmill; S Jefferies
Journal:  Br J Radiol       Date:  2012-08       Impact factor: 3.039

Review 5.  Interobserver variation in parotid gland delineation: a study of its impact on intensity-modulated radiotherapy solutions with a systematic review of the literature.

Authors:  S W Loo; W M C Martin; P Smith; S Cherian; T W Roques
Journal:  Br J Radiol       Date:  2012-08       Impact factor: 3.039

Review 6.  Vision 20/20: perspectives on automated image segmentation for radiotherapy.

Authors:  Gregory Sharp; Karl D Fritscher; Vladimir Pekar; Marta Peroni; Nadya Shusharina; Harini Veeraraghavan; Jinzhong Yang
Journal:  Med Phys       Date:  2014-05       Impact factor: 4.071

7.  Multicenter evaluation of different target volume delineation concepts in pediatric Hodgkin's lymphoma. A case study.

Authors:  C Lütgendorf-Caucig; I Fotina; E Gallop-Evans; L Claude; J Lindh; T Pelz; B Knäusl; D Georg; R Pötter; K Dieckmann
Journal:  Strahlenther Onkol       Date:  2012-10-10       Impact factor: 3.621

8.  Inter-observer variation of hippocampus delineation in hippocampal avoidance prophylactic cranial irradiation.

Authors:  F Bartel; M van Herk; H Vrenken; F Vandaele; S Sunaert; K de Jaeger; N J Dollekamp; C Carbaat; E Lamers; E M T Dieleman; Y Lievens; D de Ruysscher; S B Schagen; M B de Ruiter; J C de Munck; J Belderbos
Journal:  Clin Transl Oncol       Date:  2018-06-06       Impact factor: 3.405

9.  Volume Delineation in Cervical Cancer With T2 and Diffusion-weighted MRI: Agreement on Volumes Between Observers.

Authors:  Consuelo Rosa; Andrea Delli Pizzi; Antonietta Augurio; Luciana Caravatta; Monica DI Tommaso; Erica Mincuzzi; Sebastiano Cinalli; Raffaella Basilico; Annamaria Porreca; Marta DI Nicola; Domenico Genovesi
Journal:  In Vivo       Date:  2020 Jul-Aug       Impact factor: 2.155

10.  Dosimetric consequences of interobserver variability in delineating the organs at risk in gynecologic interstitial brachytherapy.

Authors:  Antonio L Damato; Kanopkis Townamchai; Michele Albert; Ryan J Bair; Robert A Cormack; Joanne Jang; Arpad Kovacs; Larissa J Lee; Kimberley S Mak; Kristina L Mirabeau-Beale; Kent W Mouw; John G Phillips; Jennifer L Pretz; Andrea L Russo; John H Lewis; Akila N Viswanathan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-05-03       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.