Literature DB >> 30530358

Personalized Models for Injected Activity Levels in SPECT Myocardial Perfusion Imaging.

Albert Juan Ramon, Yongyi Yang, P Hendrik Pretorius, Karen L Johnson, Michael A King, Miles N Wernick.   

Abstract

We propose a patient-specific ("personalized") approach for tailoring the injected activities to individual patients in order to achieve dose reduction in SPECT-myocardial perfusion imaging (MPI). First, we develop a strategy to determine the minimum dose levels required for each patient in a large set of clinical acquisitions (857 subjects) such that the reconstructed images are sufficiently similar to that obtained at conventional clinical dose. We then apply machine learning models to predict the required dose levels on an individual basis based on a set of patient attributes which include body measurements and various clinical variables. We demonstrate the personalized dose models for two commonly used reconstruction methods in clinical SPECT-MPI: 1) conventional filtered backprojection (FBP) with post-filtering and 2) ordered-subsets expectation-maximization (OS-EM) with corrections for attenuation, scatter and resolution, and evaluate their performance in perfusion-defect detection by using the clinical Quantitative Perfusion SPECT software package. The results indicate that the achieved dose reduction can vary greatly among individuals from their conventional clinical dose and that the personalized dose models can achieve further reduction on average compared with a global (non-patient specific) dose reduction approach. In particular, the average personalized dose level can be reduced to 58% and 54% of the full clinical dose, respectively, for FBP and OS-EM reconstruction, while without deteriorating the accuracy in perfusion-defect detection. Furthermore, with the average personalized dose further reduced to only 16% of full dose, OS-EM can still achieve a detection accuracy level comparable to that of FBP with full dose.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30530358      PMCID: PMC6582653          DOI: 10.1109/TMI.2018.2885319

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  34 in total

1.  Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.

Authors:  Freek J Beekman; Hugo W A M de Jong; Sander van Geloven
Journal:  IEEE Trans Med Imaging       Date:  2002-08       Impact factor: 10.048

2.  Random forest: a classification and regression tool for compound classification and QSAR modeling.

Authors:  Vladimir Svetnik; Andy Liaw; Christopher Tong; J Christopher Culberson; Robert P Sheridan; Bradley P Feuston
Journal:  J Chem Inf Comput Sci       Date:  2003 Nov-Dec

3.  Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies.

Authors:  Salvador Borges-Neto; Robert A Pagnanelli; Linda K Shaw; Emily Honeycutt; Shuli C Shwartz; George L Adams; Ralph Edward Coleman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

4.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

5.  4D reconstruction for low-dose cardiac gated SPECT.

Authors:  Mingwu Jin; Xiaofeng Niu; Wenyuan Qi; Yongyi Yang; Joyoni Dey; Michael A King; Seth Dahlberg; Miles N Wernick
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers.

Authors:  Milena J Henzlova; W Lane Duvall; Andrew J Einstein; Mark I Travin; Hein J Verberne
Journal:  J Nucl Cardiol       Date:  2016-06       Impact factor: 5.952

7.  4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Chao Song; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2017-04-04       Impact factor: 10.048

8.  Half-time SPECT myocardial perfusion imaging with attenuation correction.

Authors:  Iftikhar Ali; Terrence D Ruddy; Abdulaziz Almgrahi; Frank G Anstett; R Glenn Wells
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

9.  Comparison of methods of acquiring attenuation maps for cardiac SPECT in the presence of respiratory motion.

Authors:  Arda Könik; Janusz Kikut; Richard Lew; Karen Johnson; Michael A King
Journal:  J Nucl Cardiol       Date:  2013-10-22       Impact factor: 5.952

10.  Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS).

Authors:  Andrew J Einstein; Thomas N B Pascual; Mathew Mercuri; Ganesan Karthikeyan; João V Vitola; John J Mahmarian; Nathan Better; Salah E Bouyoucef; Henry Hee-Seung Bom; Vikram Lele; V Peter C Magboo; Erick Alexánderson; Adel H Allam; Mouaz H Al-Mallah; Albert Flotats; Scott Jerome; Philipp A Kaufmann; Osnat Luxenburg; Leslee J Shaw; S Richard Underwood; Madan M Rehani; Ravi Kashyap; Diana Paez; Maurizio Dondi
Journal:  Eur Heart J       Date:  2015-04-21       Impact factor: 29.983

View more
  2 in total

1.  Improving Diagnostic Accuracy in Low-Dose SPECT Myocardial Perfusion Imaging With Convolutional Denoising Networks.

Authors:  Albert Juan Ramon; Yongyi Yang; P Hendrik Pretorius; Karen L Johnson; Michael A King; Miles N Wernick
Journal:  IEEE Trans Med Imaging       Date:  2020-03-10       Impact factor: 11.037

2.  An Algorithm for Individual Dosage in Cadmium-Zinc-Telluride SPECT-Gated Radionuclide Angiography.

Authors:  Maria Normand Hansen; Christian Haarmark; Bent Kristensen; Bo Zerahn
Journal:  Diagnostics (Basel)       Date:  2021-12-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.