Deep learning with noise-to-noise training for denoising in SPECT myocardial perfusion imaging.

Junchi Liu1, Yongyi Yang1, Miles N Wernick1, P Hendrik Pretorius2, Michael A King2.   

Abstract

PURPOSE: Post-reconstruction filtering is often applied for noise suppression due to limited data counts in myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT). We study a deep learning (DL) approach for denoising in conventional SPECT-MPI acquisitions, and investigate whether it can be more effective for improving the detectability of perfusion defects compared to traditional postfiltering.
METHODS: Owing to the lack of ground truth in clinical studies, we adopt a noise-to-noise (N2N) training approach for denoising in SPECT-MPI images. We consider a coupled U-Net (CU-Net) structure which is designed to improve learning efficiency through feature map reuse. For network training we employ a bootstrap procedure to generate multiple noise realizations from list-mode clinical acquisitions. In the experiments we demonstrated the proposed approach on a set of 895 clinical studies, where the iterative OSEM algorithm with three-dimensional (3D) Gaussian postfiltering was used to reconstruct the images. We investigated the detection performance of perfusion defects in the reconstructed images using the non-prewhitening matched filter (NPWMF), evaluated the uniformity of left ventricular (LV) wall in terms of image intensity, and quantified the effect of smoothing on the spatial resolution of the reconstructed LV wall by using its full-width at half-maximum (FWHM).
RESULTS: Compared to OSEM with Gaussian postfiltering, the DL denoised images with CU-Net significantly improved the detection performance of perfusion defects at all contrast levels (65%, 50%, 35%, and 20%). The signal-to-noise ratio (SNRD ) in the NPWMF output was increased on average by 8% over optimal Gaussian smoothing (P < 10-4 , paired t-test), while the inter-subject variability was greatly reduced. The CU-Net also outperformed a 3D nonlocal means (NLM) filter and a convolutional autoencoder (CAE) denoising network in terms of SNRD . In addition, the FWHM of the LV wall in the reconstructed images was varied by less than 1%. Furthermore, CU-Net also improved the detection performance when the images were processed with less post-reconstruction smoothing (a trade-off of increased noise for better LV resolution), with SNRD improved on average by 23%.
CONCLUSIONS: The proposed DL with N2N training approach can yield additional noise suppression in SPECT-MPI images over conventional postfiltering. For perfusion defect detection, DL with CU-Net could outperform conventional 3D Gaussian filtering with optimal setting as well as NLM and CAE.
© 2020 American Association of Physicists in Medicine.

Entities:  

Keywords:  SPECT MPI; deep learning; noise-to-noise training; post-reconstruction filtering

Mesh:

Year:  2020        PMID: 33145782      PMCID: PMC7902415          DOI: 10.1002/mp.14577

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  27 in total

1.  Objective assessment of image quality: effects of quantum noise and object variability.

Authors:  H H Barrett
Journal:  J Opt Soc Am A       Date:  1990-07       Impact factor: 2.129

2.  Beyond a Gaussian Denoiser: Residual Learning of Deep CNN for Image Denoising.

Authors:  Kai Zhang; Wangmeng Zuo; Yunjin Chen; Deyu Meng; Lei Zhang
Journal:  IEEE Trans Image Process       Date:  2017-02-01       Impact factor: 10.856

3.  Low-Dose CT Image Denoising Using a Generative Adversarial Network With Wasserstein Distance and Perceptual Loss.

Authors:  Qingsong Yang; Pingkun Yan; Yanbo Zhang; Hengyong Yu; Yongyi Shi; Xuanqin Mou; Mannudeep K Kalra; Yi Zhang; Ling Sun; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

4.  3-D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning From a 2-D Trained Network.

Authors:  Hongming Shan; Yi Zhang; Qingsong Yang; Uwe Kruger; Mannudeep K Kalra; Ling Sun; Wenxiang Cong; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

5.  4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Chao Song; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2017-04-04       Impact factor: 10.048

6.  Retrospective fractional dose reduction in Tc-99m cardiac perfusion SPECT/CT patients: A human and model observer study.

Authors:  P Hendrik Pretorius; Albert Juan Ramon; Michael A King; Arda Konik; Seth T Dahlberg; Mathew W Parker; Naomi F Botkin; Karen L Johnson; Yongyi Yang; Miles N Wernick
Journal:  J Nucl Cardiol       Date:  2019-05-10       Impact factor: 5.952

7.  Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy.

Authors:  Albert Juan Ramon; Yongyi Yang; P Hendrik Pretorius; Piotr J Slomka; Karen L Johnson; Michael A King; Miles N Wernick
Journal:  J Nucl Cardiol       Date:  2017-05-23       Impact factor: 3.872

8.  Filtering in SPECT Image Reconstruction.

Authors:  Maria Lyra; Agapi Ploussi
Journal:  Int J Biomed Imaging       Date:  2011-06-23

9.  Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET.

Authors:  Hyeon Sik Kim; Sang-Geon Cho; Ju Han Kim; Seong Young Kwon; Byeong-Il Lee; Hee-Seung Bom
Journal:  Asia Ocean J Nucl Med Biol       Date:  2014

10.  Postreconstruction filtering of 3D PET images by using weighted higher-order singular value decomposition.

Authors:  Hongbo Liu; Kun Wang; Jie Tian
Journal:  Biomed Eng Online       Date:  2016-08-27       Impact factor: 2.819

View more
  4 in total

Review 1.  Applications of artificial intelligence in nuclear medicine image generation.

Authors:  Zhibiao Cheng; Junhai Wen; Gang Huang; Jianhua Yan
Journal:  Quant Imaging Med Surg       Date:  2021-06

2.  Ultra high speed SPECT bone imaging enabled by a deep learning enhancement method: a proof of concept.

Authors:  Boyang Pan; Na Qi; Qingyuan Meng; Jiachen Wang; Siyue Peng; Chengxiao Qi; Nan-Jie Gong; Jun Zhao
Journal:  EJNMMI Phys       Date:  2022-06-13

3.  Improving detection accuracy of perfusion defect in standard dose SPECT-myocardial perfusion imaging by deep-learning denoising.

Authors:  Junchi Liu; Yongyi Yang; Miles N Wernick; P Hendrik Pretorius; Piotr J Slomka; Michael A King
Journal:  J Nucl Cardiol       Date:  2021-07-19       Impact factor: 3.872

4.  Prediction of an oxygen extraction fraction map by convolutional neural network: validation of input data among MR and PET images.

Authors:  Keisuke Matsubara; Masanobu Ibaraki; Yuki Shinohara; Noriyuki Takahashi; Hideto Toyoshima; Toshibumi Kinoshita
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-04-05       Impact factor: 2.924

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.